MAURY USCG vessel records Sign in
← All vessels

LAKE SUPERIOR

LAKE SUPERIOR is a 1982 freight ship. The Coast Guard has recorded 28 inspections since 1988, most recently in March 2008, along with 26 deficiencies and 5 operational controls.

Records from 1988 to 2008. Most recent: inspection, 5 March 2008.

Built
1982
Last inspected
5 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8025991 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227018
Flag
CYPRUS
—
Maury page id
psix-227018

Inspections, by type

…with no type recorded19
Years with a record 13 calendar years (1988–2008)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it10523 - Convention (Subpart B), Net Ton
17842 - Convention (Subpart B), Gross Ton
37727 - Displacement, Ton
30670 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

5 March 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3154655
3 January 2007 PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2849146
27 April 2005 ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2343394
23 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2247262
23 August 2004 ISPS II Exam · NPV Safety Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2173834
19 August 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2170943
14 October 2003 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1928342
2 April 2003 Deficiency Check · Administrative Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1767005
30 March 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1766185
18 October 2002 Passenger/Freight Vessel Examination · Administrative Inspection · Annual Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1695055
7 October 2002 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1686022
26 September 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1680651
21 December 2001 Damage Survey
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1479921
4 December 2001 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 295786
9 October 2001 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 294519
19 August 2000 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 281180
12 April 2000 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 276803
3 April 2000 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 276006
29 March 2000 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 276220
8 September 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 432564
28 May 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 429087
18 May 1999 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 428595
22 May 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 416286
17 May 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 416049
25 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 675285
3 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 395031
25 March 1990 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 336154
8 September 1988 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 325436

Deficiency record · 26

Communications › Internal Communications System › Sound-powered Telephone
Issued 27 April 2005 Resolved
The vessel does not have effective means of communications between the navigation bridge and the steering gear room. Both the install manual call box and hand held radios were tested and found to be inconsistent and/or unreliable.
Due 27 April 2005
Resolved 27 April 2005
Resolution: The ship’s electrician was able to rectify the problem prior to the departure of the Coast Guard.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 14 October 2003 Resolved
Have Class Society verify the proper operation and condition of the hospital space within 45 days or by next U.S. port. There was no hot water and no drainage in the tub basin. The deck has rust and is in poor condition.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 November 2003
Resolved 23 August 2004
Resolution: Cleared to the satisfaction of class. Receive class report attesting to repairs
Fire Fighting › Fire Hoses
Issued 14 October 2003 Resolved
Prior to departure, replace all wasted fire hoses. Hoses are on order as of 14Oct03. Vessel is due to leave 15Oct03. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2003
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 14 October 2003 Resolved
Provide onboard navigational current tables for the bridge within 30 days.
Action required: 15 - Rectify deficiencies by next port
Due 13 November 2003
Resolved 23 August 2004
Resolution: Vessel had on board navigational current tables.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 October 2003 Resolved
Update fire control plan to show missing items and have Class Society approve plan and send report to U.S. Coast Guard within 30 days or by next U.S. port.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 13 November 2003
Resolved 23 August 2004
Resolution: Fire control plan updated to the satisfaction of class, [name withheld] attested to changes to Fire Control Plan
Lifesaving › Lifejacket/PFD (Type I)
Issued 18 October 2002 Resolved
Life Jacket not stenciled with vessel name. LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2003
Resolution: Received proper documentation satisfying requirement.
Fire Fighting › Fire Hydrants
Issued 18 October 2002 Resolved
Handle on fire monitor broke making charging of fire monitor impossible. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2003
Resolution: Received proper documentation satisfying requirement.
Pollution Prevention/Response › Prevention Equipment
Issued 26 September 2002 Resolved
SEWAGE LINE ABOVE MSD LEAKING LEGACY COMPONENT DESC: Sewage System Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2002
Electrical › Electric Generation Source (service)
Issued 26 September 2002 Resolved
#2 GENERATOR COOLING WATER LINE FOR J/W AND L/0 COOLERS HAS SOFT PATCH. LINE MUST BE REPLACED. LEGACY COMPONENT DESC: Generator
Action required: 15 - Rectify deficiencies by next port
Resolved 2 October 2002
Electrical › Electrical Distribution System (service)
Issued 21 December 2001 Resolved
#3 S/S generator tripped off line due to loose connection at bus tie breaker. Generator was not paralleled which caused vsl to lose power. # 3 S/S generator breaker was again manually closed by ships crew and carried the load normally. #2 S/S generator was placed on line in parallel. LEGACY COMPONENT DESC: Bus Bar Connection
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2001
Resolved 22 December 2001
Resolution: Class Society and ships engineers discovered cause after a thorough check of the ships main electrical panel.
Electrical › Electrical Distribution System (emergency)
Issued 21 December 2001 Resolved
Emergency lighting generator failed to start due to the battery was dead which was caused by the battery charger not working. The wire was broken to the AC/DC rectifier in the battery charger. LEGACY COMPONENT DESC: Starting battery
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 December 2001
Resolved 22 December 2001
Resolution: Battery charger was repaired by ships crew. Battery in satisfactory condition, however, Class society representative is arranging for vessel to pick up new battery at next port of call.
Navigation
Issued 28 May 1999 Resolved
Light List Vol VII is outdated._x001C_
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Documentation
Issued 18 May 1999 Resolved
CORRECT FIRE PLANS TO BE IN A LANGUAGE UNDERSTOOD BY CREW._x001C_ _x001C_ SOLAS 74(A)III/8.4
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Engineering
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO FUEL RETURN TUBING ON #1SSDG._x001C_ _x001C_ SOLAS 74 (A) II-I/26
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Fire Fighting
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO SUCTION SIDE PIPE FOR GS PUMP IN WAY OF FLANGE ATVALVE. CONDITION OF CLASS IMPOSED FOR PERMANENT REPAIR TO BE COMPLETED BY _x001C_JUNE 99._x001C_ ILLC 66
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO SUCTION PIPE FOR MSD SEWAGE TRANSFER PUMP._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO DISCHARGE PIPE FOR MSD SEWAGE DISCHARGE PUMP._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 9 September 1999
Resolved 9 September 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
COMPLETE WELDING ON INSERT ON TOP OF MSD._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO VENT PIPE ON MSD._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO MSD TANK IN WAY OF HIGH LEVEL ALARM SENDING UNIT._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Accommodation/Occupational Safety
Issued 18 May 1999 Resolved
MAKE PERMANENT REPAIRS TO INLET SIDE OF SEWAGE INLET VALVE TO MSD._x001C_ _x001C_ 33CFR159
Condition: Unknown
Due 29 May 1999
Resolved 29 May 1999
Engineering
Issued 18 May 1999 Resolved
CLASS TO ATTEST TO PROPER INSTALLATION OF F/O RETURN LINES FROM ALL 3 SSDGS. RETURNS ARE CURRENTLY DRAINING INTO BILGE._x001C_ _x001C_ SOLAS 74(A)reg II-I/26
Condition: Unknown
Due 18 May 1999
Resolved 19 May 1999
Lifesaving
Issued 17 May 1998 Resolved
Starboard lifeboat davit brake handle broke during abandon ship drill. Crew made temp repairs, permanent repair/replacement required iaw SOLS 74 III/48
Condition: Unknown
Due 23 May 1998
Resolved 23 May 1998
Navigation
Issued 3 September 1996 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD. VESSEL ACQUIRED A COPY PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 September 1996
Resolved 3 September 1996
Navigation
Issued 8 September 1988 Resolved
VESSEL MISSING ONE CHART. CHART NUMBER AND NAME 14826, MOSS PT. TO VERMILLION.
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988
Navigation
Issued 8 September 1988 Resolved
MISSING GREAT LAKES LIGHT LISTAS REQUIRED BY 33 CFR 164.33.
Condition: Unknown
Due 8 September 1988
Resolved 8 September 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.