← All vessels
OCEAN PRITI
OCEAN PRITI is a 1982 freight ship. The Coast Guard has recorded 17 inspections since 1984, most recently in July 2001, along with 50 deficiencies and 3 operational controls.
Records from 1984 to 2001. Most recent: operational control imposed, 3 July 2001.
- Built
- 1982
- Last inspected
- 3 July 2001
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 50 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8026660 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EFF2
227023
Flag
PANAMA
—
Maury page id
psix-227023
Inspections, by type
…with no type recorded17
Years with a record
12 calendar years (1984–2001)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it10829 - Regulatory (Subpart C or D), Net Ton
15904 - Regulatory (Subpart C or D), Gross Ton
27019 - Dead Weight, Ton
15904 - Regulatory (Subpart C or D), Gross Ton
27019 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
3 July 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 291589
13 December 1999
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 435784
7 December 1999
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 435329
24 May 1998
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 416216
15 May 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 415810
17 September 1997
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 407973
7 May 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403356
14 September 1995
Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 382663
18 August 1995
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 381633
19 December 1994
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 373208
10 December 1994
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 373283
28 October 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 362401
6 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 351731
16 July 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 331464
16 May 1988
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 436288
15 August 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 317613
14 May 1984
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 296319
Deficiency record · 50
Fire Fighting
Issued 3 July 2001
Resolved
EMERGENCY FIRE PUMP NOT READILY AVAIIBLE FOR USE & EXCESSIVELY LEAKING EXHAUST FUMES. REPAIR AND PROVE PROPER OPERATION TO THE SATISFACTION OF THESAFETY EQUIPMENT CERTIFICATE ISSUING AUTHORITY PRIOR TO DEPARTURE FROM HOUMS. IAW SOLAS 74 AMENDED II-2/REG 21._x001C_
Navigation
Issued 3 July 2001
Resolved
BRIDGE RUDDER ANGLE INDICATOR OFF BY 3-5 DEGREES FROM STEERING GEAR RUDDER POST. CORRECT TO THE SATISFACTION OF THE SAFETY CONSTRUCTION CERIFICATE ISSUING AUTHORITY, PRIOR TO DEPARTURE FROM HOUMS. IAW SOLAS 74 II-1/REG 29.
Lifesaving
Issued 7 December 1999
Resolved
Hydrostatic Release Valve outdated. To be replaced at next POC: TOLMS
Navigation
Issued 24 May 1998
Resolved
The Echo Depth Sounder's transmitter was inoperable. A condition of class (DNV) issued 16May98, required the transmitter to be repaired at next dry dock by 31Aug98.
Navigation
Issued 15 May 1998
Resolved
BRIDGE ECHO DEPTH SOUNDER RECORDER INOPERATIVE. CLASS (DNV) INSPECTED AND REPORTS UNIT REQUIRES RENEWAL IN SHIPYARD ON 31 AUG 98. LOD ISSUED FOR DEPARTURE FROM PORT.
Lifesaving
Issued 15 May 1998
Resolved
PORT LIFEBOAT MOTOR/DRIVE PROPULSION INOPERATIVE.
Fire Fighting
Issued 15 May 1998
Resolved
FOUND MAIN DECK PIPING STBD SIDE AMIDSHIPS HOLED FROM RUST. REPAIRED AND INSPECTED TO SATISFACTION OF CLASS (DNV) AND MI.
Navigation
Issued 17 September 1997
Resolved
U.S. COAST PILOT MISSING.
Lifesaving
Issued 17 September 1997
Resolved
EXCESS OIL TO BE CLEANED FROM ENGINE ROOM.
Navigation
Issued 17 September 1997
Resolved
U.S. LIGHT LIST MISSING.
Lifesaving
Issued 17 September 1997
Resolved
PAINT STORED IN AFTER STEERING - NOT STORED IN PAINT LOCKER.
Lifesaving
Issued 17 September 1997
Resolved
REMOVE OILY RAGS FROM ENGINE ROOM.
Lifesaving
Issued 17 September 1997
Resolved
CLEAN EXCESS OIL FROM STEERING FLAT.
Engineering
Issued 7 May 1997
Resolved
Numerous pumps in the lower machinery space ( & emergency fire pump space) have belt driven priming pumps with the belts disabled & guards removed. Also note the leaking prime lines on the two port E/R pumps (lower level). Make repairs as necessary prior to return to a U. S. port. SOLAS 74 I/11
Electrical
Issued 7 May 1997
Resolved
Remove the numerous heat lamps on the various E/R pumps and steering gear pumps. Install class approved heat strips as necessary prior to return to a U. S. port. _x001C_ SOLAS 74 I/11
Electrical
Issued 7 May 1997
Resolved
Sort / repair / rewire the electrical wiring mess on the auxiliary boiler burner assemble prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Construction/Loadline
Issued 7 May 1997
Resolved
Make permanent repairs to the various fractures in the fore & aft hatch coaming stays on the midships cargo holds prior to return to a U. S. port. _x001C_ ICLL 66 II/16
Fire Fighting
Issued 7 May 1997
Resolved
Remove the hold back hooks on all machinery space fire doors and assure they remain in a closed position prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/20
Engineering
Issued 7 May 1997
Resolved
Make permanent repairs to the leaking cooling line to the outboard M/E air compressor prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Engineering
Issued 7 May 1997
Resolved
Make permanent repairs to the wasted & leaking head on the inboard M/E air compressor heat exchanger prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Engineering
Issued 7 May 1997
Resolved
Make permanent repairs to the wasted section of cooling piping on the M/E J/W heat exchanger prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Navigation
Issued 7 May 1997
Resolved
Remove the bucket from the hydraulic oil head tank on the steering gear. Have class address issue of tank size and make modifications as necessary. CHENG complains that tanks constantly burps oil during operations as it is too small. Complete prior to return to a U. S. port. SOLAS 74 II-1/29
Deck/Cargo
Issued 7 May 1997
Resolved
Make permanent repairs to the leaking hydraulic systems on the forecastle deck prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 151.10.b
Electrical
Issued 7 May 1997
Resolved
Remove the dead ended cable from about the M/E governor control station prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Electrical
Issued 7 May 1997
Resolved
Remove the wooden mounting board with cable extensions adjacent to the stbdfire pump prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Lifesaving
Issued 7 May 1997
Resolved
Make repairs to the port lifeboat engine to allow it to start without use of a burning rag (to raise temp of intake air). Complete prior to departure. _x001C_ SOLAS 74 III/9
Fire Fighting
Issued 7 May 1997
Resolved
Remove the rubber fuel supply & return lines on the emergency fire pump engine and replace with steel lines prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/52.b
Engineering
Issued 7 May 1997
Resolved
Clean the excessive oil from about the main bilges, generator engine bilges, D/O & L/O purifiers, steering gear machinery, M/E governor / control station, and aft deck machinery hyd. pump prior to return to a U. S. port. SOLAS 74 I/11
Navigation
Issued 7 May 1997
Resolved
The operator of the emergency steering gear cannot view the position of therudder angle indicator during operation. Have class address this issue andmake corrections as required prior to return to a U. S. port. _x001C_ SOLAS 74 II-1/29
Accommodation/Occupational Safety
Issued 7 May 1997
Resolved
Renew the rubber water hose over the exit from the steering gear space withsteel (or provide a valve to isolate) prior to return to a U. S. port. _x001C_ SOLAS 74 I/11
Electrical
Issued 7 May 1997
Resolved
Repair the cable break beneath the steering gear control panels prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Electrical
Issued 7 May 1997
Resolved
Replace the missing control switches on the steering gear electrical panelsprior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/27
Electrical
Issued 7 May 1997
Resolved
Repair the taped solenoid valve / control on the OWS prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Electrical
Issued 7 May 1997
Resolved
Repack the power cables on the steering gear motors to prevent housing fromchaffing against bare wires prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Accommodation/Occupational Safety
Issued 7 May 1997
Resolved
Assure all machinery space double bottom sounding tubes remain closed when not in use. _x001C_ _x001C_ SOLAS 74 I/11
Engineering
Issued 7 May 1997
Resolved
Repair the fuel oil duplex filter to prevent oil leaks prior to return to aU. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Engineering
Issued 7 May 1997
Resolved
Make permanent repairs to the wasted cooling line above the OWS prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/52
Construction/Loadline
Issued 18 August 1995
Resolved
STBDSIDE AFT FANTAIL HATCH FOUND WASTED, NO GASKET MATERIAL. TO BE REPAIREDOR REPLACED AS PER OUTSTANDING CONDITION OF CLASS. FOC'SLE HATCH BATTERED_x001C_ BEYOND REPAIR DURING HURRICANE FELIX. RENEWED IN BALTIMORE.
Construction/Loadline
Issued 18 August 1995
Resolved
CARGO HATCH GASKETS MISSING ON VARIOUS HOLDS_x001C_ _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 18 August 1995
Resolved
FOLLOWING FIRESTATION VALVES FOUND UNSERVICABLE(VALVE STEMS SNAPPED OFF DUETO VALVES FROZE SHUT) FOC'SLE PORT AND STBD AFT STATIONS, PORTSIDE MAINDECK2 VALVES ABEAM 1 HOLD AND 1 ABEAM 7 HOLD. STBD BRIDGE WING AND STBD STACK_x001C_ DECK, PORTSIDE 02 DECK AFT. VALVES ORDERED FOR CANADA PORTCALL 07SEP95._x001C_
Construction/Loadline
Issued 18 August 1995
Resolved
CARGO HOLD ACCESS HATCHES ALL MISSING DOGGING DEVICES._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 18 August 1995
Resolved
IMPROPER INSTALLATION OF HEAT LAMPS OVER ELECTRIC HYDRAULIC PUMP MOTORS_x001C_ UNDER THE FOC'SLE. LAMPS JUST SWINGING ON THERE POWER WIRING._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 18 August 1995
Resolved
EMERGENCY FIRE PUMP HAS EXHAUST LEAK IN PIPING IN COMPARTMENT WITH PUMP._x001C_
Lifesaving
Issued 18 August 1995
Resolved
ALL WATERLIGHTS FOUND MISSING OR INOP, LIGHTS CARRIED AWAY DURING HURRICANEFELIX _x001C_
Deck/Cargo
Issued 18 August 1995
Resolved
COMPRESSOR IN AIRCONDITIONER MACHINERY COMPARTMENT MISSING GUARD CAGE TO HOUSE MOVING PULLEYS AND DRIVE BELTS.
Navigation
Issued 18 August 1995
Resolved
ALDIST LAMP PLUGGED INTO WRONG OUTLET DURING A/E. BULB BLOWN WHEN ENERGIZED_x001C_ _x001C_ _x001C_
Engineering
Issued 18 August 1995
Resolved
FUEL VENT CONTAINMENT TO DIESEL OIL TNK #5 TORN FM MOUNTINGS LOCATED STBD_x001C_ SIDE BETWEEN CARGO HOLDS 4 AND 5. TO RENEW CONTAINMENT AT SEA, NO TRANSFER OF FUEL TO THIS TANK TO TAKE PLACE UNTIL REPAIR COMPLETED._x001C_ _x001C_
Lifesaving
Issued 18 August 1995
Resolved
PORT AND STBD LIFEBOATS SEVERLY HOLED WERE BOATS REST ON DAVIT PADS. BOATS TO BE REPAIRED OR REPLACED PRIOR TO 28OCT95 AS PER AUTHORIZATION FM FLAG STATE OF PANAMA. ADDTIONAL LIFERAFT CAPACITY OF 36 PEOPLE INSTALLED BOTH PORT AND STBD SIDES. ZODIAC PONTOON BOAT WITH MOTOR INSTALLED FOR RES. BOAT
Unknown
Issued 28 October 1993
Resolved
Vessel Marine Sanitation Device was missing proper label and was not being operated as a type II MSD. The vessel was directed to label the MSD as a type II or type III depending on use. At the time of the boarding the MSD was used as a type III.
Unknown
Issued 28 October 1993
Resolved
Pollution placard missing in vicinity of the Oily-water seperator. Copy ofplacards posted in other required spaces to be made and placed as appropriate.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.