MAURY USCG vessel records Sign in
← All vessels

AKROPOLIS

AKROPOLIS is a 1983 freight ship. The Coast Guard has recorded 20 inspections since 1985, most recently in July 2006, along with 19 deficiencies and 1 operational control.

Records from 1985 to 2006. Most recent: inspection, 18 July 2006.

Built
1983
Last inspected
18 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8028149 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227035
Flag
PANAMA
—
Maury page id
psix-227035

Inspections, by type

…with no type recorded17
Years with a record 14 calendar years (1985–2006)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it22312 - Regulatory (Subpart C or D), Net Ton
35911 - Regulatory (Subpart C or D), Gross Ton
63883 - Dead Weight, Ton
76420 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

18 July 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2716913
6 February 2006 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2580517
29 November 2005 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2542919
28 January 2005 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2281999
28 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2282170
30 April 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 402984
9 February 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 387834
5 April 1995 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 376589
9 September 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 370365
9 September 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869735
9 August 1993 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360005
27 October 1992 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 353949
4 January 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 348020
7 February 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 335093
15 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 504582
22 February 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 328636
9 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320069
22 April 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 308138
10 September 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 455294
3 July 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 302839

Deficiency record · 19

Fire Fighting › Means of Escape › Doorways
Issued 29 November 2005 Resolved
The self closing doors for machinery space escape trunk do not fully self close.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 December 2005
Resolved 6 February 2006
Resolution: The self closing door was fixed with the proper closing mechanism.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 28 January 2005 Resolved
Received report from ship pilot that vessel experienced a power irregularity. Problem occurred when pilot ordered "stop" and "full astern" from a full ahead position. Chief engineer states that the CAM delayed while trying to turn in opposite direction.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the course of the PSC inspection the [name withheld] surveyor, and Class surveyor all tested propulsion system independently and found all to be satisfactory. Received class report while onboard.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 January 2005 Resolved
During the course of the PSC inspection the PSCO found the safety hand rail (located in front of engine control room over-hanging the MDE bay-below crane hoisting beam)with a broken weld and missing bolts. This arrangement creates a safety hazard for crew.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: Crew repaired hand rail while inspection team was onboard. Cleared deficiency.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 28 January 2005 Resolved
Found no source of safety railing or non-skid around steering gear assembly. This creates an unsafe environment for workers.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the inspection, the crew placed a non-skid surface around steering gear assembly.
Engineering › Steering Gear System › Piping
Issued 28 January 2005 Resolved
Found a continuous hydraulic oil leak at STBD steering pump supply line that feeds main rudder block.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the inspection, crew repaired leak on steering pump supply line.
Construction/Loadline › Structures › Deck Plating
Issued 28 January 2005 Resolved
Found severely corroded cat walk grating between anchor assembly on bow. Creates an unsafe working environment for crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: Crew repaired cat walk grating by bolting down plating while Coast Guard was onboard.
Navigation › Piloting/Steering › Swing Meter
Issued 28 January 2005 Resolved
Found both rudder angle indicators on bridge wings to hold a 5 degree variance than that shown on main bridge rudder angle indicator and steering gear room indicator.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the Coast Guard inspection, the electrician officer corrected both steering gear indicators.
Fire Fighting › Portable Foam Applicators › General
Issued 28 January 2005 Resolved
Found fire extinguisher on lower deck of engine room's(PORTSIDE)(serial # 3540-last inspected 30-10-2004) charge indicator expressing red indication (undercharged).
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the Coast Guard inspection, the crew replaced the fire extinguisher with a fully charged extinguisher.
Engineering › Generator (propulsion-electric) › Feeder Circuitry
Issued 28 January 2005 Resolved
Found #2 main service generator's primer feeder piping fittings with a temporary clamp. Make permanent repair to tighten and prevent oil leakage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the inspection, crew made permanent repair to tighten and prevent oil leakage with bolts.
Construction/Loadline › Structures › Deck Plating
Issued 28 January 2005 Resolved
Found lifeboat deck grating on PORTSIDE severely corroded causing a safety hazard for crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 January 2005
Resolved 28 January 2005
Resolution: During the inspection, crew replaced grating and secured with bolts.
Lifesaving
Issued 9 September 1994 Resolved
EMBARCATION LADDER PORT SIDE IS DETERIORATED AND UNSAFE TO USE.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Navigation
Issued 22 February 1989 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO USCG LIGHT LIST (UK: NP.82 VOL.J) USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 48/88WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THEVSLS ROUTE FROM SMITH PT VA TO BALTIMORE HBR. NO U.S. EQUIVALENT O/B.
Condition: Unknown
Due 15 August 1989
Resolved 22 February 1989
Navigation
Issued 22 February 1989 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE FOREIGN EQUIVALENT TO U.S. CHARTS 12263, 12278, 12281, (UK: 2921, 2850) WERE NOT CORRECTED UP THRU NTMS 3760 AND 3760, WHICH WERE REASONABLY AVAIL AND CONTAINED CORR APP TO THE VSLS ROUTE FROM SMITH PT VA TO BALT HBR. NO U.S. EQUIVALENT O/B.
Condition: Unknown
Due 15 August 1989
Resolved 22 February 1989
Navigation
Issued 22 February 1989 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE U.S. CHART 12230, USED BY THE VSL WAS NOT CORRECTED UP THRU NTMS 40/88, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSLS ROUTE FROM SMITH PT VA TO BALTIMORE HBR. NO FOREIGN EQUIVALENT O/B.
Condition: Unknown
Due 15 August 1989
Resolved 22 February 1989
Navigation
Issued 22 April 1986 Resolved
THE VESSELS COAST PILOT WAS NOT CURRENTLY CORRECTED, THE VESSEL DID NOT HAVE A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 17 March 1987
Resolved 22 April 1986
Navigation
Issued 22 April 1986 Resolved
THE VESSELS CG LIGHT LIST WAS NOT CURRENTLY CORRECTED AND THERE WAS NO FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 17 March 1987
Resolved 22 April 1986
Navigation
Issued 22 April 1986 Resolved
THE VESSEL DID NOT HAVE A COPY OF THE INLAND RULES OF THE ROAD ON BOARD
Condition: Unknown
Due 17 March 1987
Resolved 22 April 1986
Documentation
Issued 22 April 1986 Resolved
THE VESSEL DID NOT CONDUCT AN ANNUAL TEST OF THE FUEL OIL TRANSFER SYSTEM
Condition: Unknown
Due 17 March 1987
Resolved 22 April 1986
Navigation
Issued 3 July 1985 Resolved
THE VESSELL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST PILOT OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 17 March 1987
Resolved 3 July 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.