CHANG FU STAR is a 1982 freight ship. The Coast Guard has recorded 28 inspections since 1984, most recently in September 2005, along with 26 deficiencies and 4 operational controls.

Records from 1984 to 2005. Most recent: inspection, 6 September 2005.

Built
1982
Last inspected
6 September 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8028888 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227045
Flag
PANAMA
—
Maury page id
psix-227045

Inspections, by type

…with no type recorded23
Years with a record 17 calendar years (1984–2005)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21754 - Regulatory (Subpart C or D), Net Ton
37472 - Regulatory (Subpart C or D), Gross Ton
63560 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

6 September 2005 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2485354
19 February 2005 Ballast Water Examination · PII Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2295701
19 February 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2296015
28 September 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2208287
20 July 2004 ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2137868
22 October 2003 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1932155
17 October 2003 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1930554
9 September 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 293533
20 March 2000 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 275913
12 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425307
30 October 1996 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396942
23 October 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 384160
4 May 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 378027
14 October 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173131
7 October 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 371222
7 October 1994 Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1173840
15 December 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 537525
5 March 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349319
9 August 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 488301
7 December 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 340725
30 November 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 340670
30 May 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 330665
11 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 321914
12 September 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 311362
17 July 1985 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 303097
12 July 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 492852
18 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 441734
18 October 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 526101

Deficiency record · 26

Navigation › Collision/Grounding Avoidance › Radar
Issued 19 February 2005 Resolved
X- Band, 3 cm radar malfunctioning. Vessel did not request inbound LOD to transit . Vessel must repair the radar to the satisfaction of a certfied technician prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 February 2005
Resolution: Received technician''s report attesting to satisfactory repairs to the radar.
Stability › Unintentional Flooding › General
Issued 19 February 2005 Resolved
Galley drain, skin valve (a valve located beneath the water line controlling overboard discharge) has a clamp patch on it. If valve fails there is a possibility of flooding the ship. Have class surveyor address prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2005
Resolution: Received Class Society report attesting to the satisfactory renewal and testing of the galley drain valve.
Deck/Cargo › Cargo Stowage › General
Issued 19 February 2005 Resolved
The #6 Cargo hold has a hole leading into #5 cargo hold. The hole is at the top of the ladder in the #6 hold. Have Class surveyor address prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2005
Resolution: Received Class Society report attesting to the satisfactory repair and hose testing of the hole.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 19 February 2005 Resolved
Holding tank for Hospital Sewage has a hole behind cover. Have class address prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2005
Resolution: Received Class Society Report attesting to the satisfactory repairs of the hole. Sewage tank was cropped and an insert was fitted.
Lifesaving
Issued 30 October 1996 Resolved
LIFELINES ON BOTH LIFEBOATS NOT SECURED TO GUNWALE IAW SOLAS 74 CH III REG 11.
Condition: Unknown
Due 31 October 1996
Resolved 5 November 1996
Navigation
Issued 30 October 1996 Resolved
VESSELS STEERING NOT OPERATING PROERLY IAW SOLAS 74 CH II REG 29.
Condition: Unknown
Due 31 October 1996
Resolved 5 November 1996
Deck/Cargo
Issued 23 October 1995 Resolved
VESSEL TO MAKE PERMENANT AND PROPER REPAORS TO HYDRAULIC LINE TO DECK WINCHBETWEEN #6 AND #7 CARGO HOLD.
Condition: Unknown
Due 5 November 1996
Resolved 5 November 1996
Lifesaving
Issued 23 October 1995 Resolved
VESSEL TO PROVIDE ON BOARD 65 PACKAGES OF LIFEBOAT FOOD. PORT AND STBD LIFEBOATS FOOD PACKAGES LOST VACUUM SEAL.
Condition: Unknown
Due 26 October 1995
Resolved 24 October 1995
Deck/Cargo
Issued 7 October 1994 Resolved
Vessels cargo hatch contols for hold #1, #2 were leaking hydraulic fluid.
Condition: Unknown
Due 14 October 1994
Resolved 20 October 1994
Engineering
Issued 7 October 1994 Resolved
Vessels 15 ppm oily-water separator was not operating.
Condition: Unknown
Due 14 October 1994
Resolved 20 October 1994
Fire Fighting
Issued 7 October 1994 Resolved
Vessels emergency fire pump was not operating.
Condition: Unknown
Due 14 October 1994
Resolved 20 October 1994
Electrical
Issued 7 October 1994 Resolved
Vessels light fixture in the forward boatswains hold was broken and showingloose wires.
Condition: Unknown
Due 7 November 1994
Resolved 24 October 1994
Documentation
Issued 5 March 1992 Resolved
vessel did not have a copy of the oil transfer procedures posted at the transfer site during operations as required by 33 C.F.R. 155.740(c).
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 5 March 1992 Resolved
vessels drains for containment and scuppers were not closed during bunkering operations as required by 33 C.F.R. 156.120(o).
Condition: Unknown
Due 9 March 1992
Resolved 9 March 1992
Lifesaving
Issued 5 March 1992 Resolved
Bolts not tightned to prevent the leakage of oil from the conntctions as per 33 C.F.R. 156.130(a)(6).
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
B.A. CHART 1082 MISSING 3 1986 CORRECTIONS. B.A. CHART 1081 MISSING ALL 1990 AND 1991 CORRECTIONS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
CHARTS 1063 AND 899 NOT ON BOARD.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
CURRENT YEAR TIDE TABLES NOT ON BOARD.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
CURRENT YEAR TIDAL CURRENT TABLES NOT ON BOARD.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
B.A. LIGHT LIST VOL.G MISSING 6 CORRECTIONS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
B.A. COAST PILOT VOL. 8 MISSING ALL CORRECTIONS.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
COPY OF INLAND NAVIGATIONAL RULES NOT ON BOARD.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Navigation
Issued 5 March 1992 Resolved
PRE-ARRIVAL TESTS NOT LOGGED IN THE BRIDGE LOG.
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Engineering
Issued 5 March 1992 Resolved
OILY WATER SEPARATOR NOT WORKING PROPERLY. CREW UNABLE TO TEST OILY WATER SEPARATOR 15 PPM ALARM AS REQUIRED BY 151.13(b)
Condition: Unknown
Due 10 March 1992
Resolved 10 March 1992
Documentation
Issued 7 December 1990 Resolved
33 CFR 151.21(b) Vessel's IOPP certifcate form A was missing the necessary supplement_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 December 1990
Resolved 7 December 1990
Documentation
Issued 30 November 1990 Resolved
33CFR151.19(d) THE VESSEL'S SUPPLEMENT TO THE IOPP WAS NOT AVAILABLE AT THE TIME OF THE BOARDING. THE CHIEF MATE OF THE VESSEL COULD NOT LOCATE THE SUPPLEMENT. _x001C_ _x001C_
Condition: Unknown
Due 30 November 1990
Resolved 30 November 1990

Ownership record