MAURY USCG vessel records Sign in
← All vessels

LEOPARDI

LEOPARDI is a 1982 freight ship. The Coast Guard has recorded 11 inspections since 1984, most recently in August 2000, along with 9 deficiencies — 4 with no resolution recorded —.

Records from 1984 to 2000. Most recent: inspection, 23 August 2000.

Built
1982
Last inspected
23 August 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8029090 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227049
Flag
LIBERIA
—
Maury page id
psix-227049

Inspections, by type

…with no type recorded11
…past their stated due date4
Years with a record 10 calendar years (1984–2000)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it46786 - Regulatory (Subpart C or D), Net Ton
67727 - Regulatory (Subpart C or D), Gross Ton
132086 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 11

23 August 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 280890
27 January 1998 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 412158
29 September 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 408279
6 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400108
20 June 1995 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 379606
10 January 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 363631
29 November 1990 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 340566
9 August 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 332009
7 December 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 320070
1 September 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 530027
14 December 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 299364

Deficiency record · 9

Engineering
Issued 23 August 2000 No resolution recorded
INSTALL GUARDS ON PROPULSION ENGINE JACKET WATER COOLING PUMPS.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Electrical
Issued 23 August 2000 No resolution recorded
PROVIDE RUBBER FLOOR MAT IN FRONT OF SWITCH BOARD FOR CARGO HATCH HYDRAULICSYSTEM.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Deck/Cargo
Issued 23 August 2000 No resolution recorded
REPLACE HYDRAULIC HOSES ON PORT SIDE AFT #5 CARGO HOLD HYDRAULIC RAM.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Lifesaving
Issued 23 August 2000 No resolution recorded
INSTALL GUARD OVER EMERGENCY FIRE PUMP DRIVE COUPLING.
Condition: Unknown
Due 23 September 2000 — due date passed with no resolution recorded
Construction/Loadline
Issued 27 January 1998 Resolved
BOSN STORE HATCH COVER ON THE BOW HOLED IS WASTED. CITE ICLL 66 RS 13-18.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Unknown
Issued 27 January 1998 Resolved
HYDRAULIC PIPING/HOSES IN DISREPAIR THROUGH THE CARGO BLOCK. MARPOL 73/78.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Fire Fighting
Issued 27 January 1998 Resolved
FIREMAIN HOLED WASTED, PORT SIDE BETWEEN HOLDS 5+6 AND HOLDS 2+3. SITE II-2REG 21.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Unknown
Issued 27 January 1998 Resolved
HATCH END GIRDER IN #5 HOLD ASFT AND #2 HOLD FWD ARE FRACTURED.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Unknown
Issued 27 January 1998 Resolved
REPAIR LEAK IN WAY OF UPPER WING BALLAST, FRAME 78.
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000

Ownership record