Records from 1984 to 2007. Most recent: operational control imposed, 18 November 2007.
Inspection history · 25
18 November 2007
ISPS III Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3100587
26 March 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2895186
29 October 2006
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2809747
12 July 2005
MARPOL Annex V Examination · ISM Exam · Loadline Exam · ISPS III Exam · Ballast Water Examination · ILO-147 Exam · MARPOL Annex I Examination · PII Safety Exam · STCW 95 Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2424487
6 July 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2417241
2 August 2004
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2254544
29 July 2004
ISPS II Exam · MARPOL Annex I Examination · PII Safety Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2144577
3 May 2004
Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2058451
1 January 2001
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 652243
28 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275216
24 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 426268
6 October 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 408615
3 March 1997
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 401069
9 October 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 396124
10 October 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383674
24 July 1995
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 380763
16 March 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 699809
13 March 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 365284
21 June 1991
Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 344487
13 December 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 334216
5 December 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 334054
21 December 1988
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 327479
13 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 317804
17 November 1986
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 312708
29 October 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 298584
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 November 2007
Resolved
Power supply to the OWS has multiple loose end wires that are not connected to anything and the light for water discharge is modified from original design.
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 20 November 2007
Resolution: received class report. IOPP withdrawn, interim given till final repairs can be made.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 November 2007
Resolved
Operators manual for oil content meter is not onboard and crew unable to prove proper operation and maintenance of oil content meter.
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 20 November 2007
Resolution: Received class report, op manual found, but oil content meter found to be inop.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 18 November 2007
No resolution recorded
Repairs to oil content meter and power supply to OWS to be repaired in Morocco via tech rep. Class to attend vls to verify repairs are made and proper operation of OWS and Oil Content Meter. Provide class report to USCG at next U. S. Port.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 20 November 2007 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Fire
Issued 12 July 2005
Resolved
Fire and abandon ship drills ineffective due to insufficient fire boundaries set, inability to dress out in fire suits, lack of mustering list available, and lack of familiarity with watch station and quarter bill.
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2005
Resolved 14 July 2005
Resolution: Drills were found to be satisfactory.
Documentation › Logs/Records › Oil Record Book
Issued 29 July 2004
Resolved
Immediately begin making C 11.1 entries in the oil record book to include all tanks listed in the IOPP section 3.1
MARPOL 73/78 Annex I/20
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2004
Resolution: Deficiency rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 July 2004
Resolved
Prove proper operation of the oily water seperator to the satisfaction of the attending class surveyor and coast guard marine inspector. Currently, when the ows alarm is sounded, the 3 way valve does not stop the overboard discharge. MARPOL 73/78 Annex I/16.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2004
Resolution: Deficiency Rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 July 2004
Resolved
Provide specific class approval of the existing ows piping arrangement. The class approved piping diagram does not depict the existing piping arrangement in the engine room. MARPOL 73/78 Annex I/16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 July 2004
Resolution: Deficiency was addressed by outstanding condition of class issued on this day. Deficiency Rectified.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 29 July 2004
Resolved
Permanently modify the ows piping arrangement to the satisfaction of class as required by outstanding condition of class dated this date. Currently sections of the ows in the vicinity of the 3 way valve have threaded connections. Also a line was found connecting the sludge pump and bilge pump to the fire pump overboard line. (This was removed prior to inspectors departure.) MARPOL 73/78 Annex I
Action required: 705 - Other - as specified
Resolved 6 July 2005
Resolution: Received class report, cleared deficiency.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 May 2004
Resolved
The Oily Water Separator system has been modified from the original design.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 17 May 2004
Resolved 6 July 2005
Resolution: Received class report, cleared deficiency.
Lifesaving › Lifeboat › Hull
Issued 3 May 2004
Resolved
The port life boat has a large patch located aft IWO of the davit block. LEGACY COMPONENT DESC: Hull
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 May 2004
Resolved 29 July 2004
Resolution: Deficiency rectified.
Unknown
Issued 24 February 1999
Resolved
PROVE PROPER OPERATION OF EMERGENCY FIRE PUMP (SOLAS 74)
Condition: Unknown
Due 27 February 1999
Resolved 5 March 1999
Unknown
Issued 24 February 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 February 1999
Resolved 5 March 1999
Fire Fighting
Issued 6 October 1997
Resolved
Repair fire main pipe where leaks, main deck starboard aft of cargo hold #4prior to next U.S. port._x001C_ (SOLAS 74 II-2/5)
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Construction/Loadline
Issued 6 October 1997
Resolved
Provide standard discharge connection prior to next U.S. port._x001C_ (MARPOL 73/78 I-19)
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Fire Fighting
Issued 6 October 1997
Resolved
Adjust engine room lower escape door to self close prior to next U.S. port.(SOLAS 74 II-2/53)
Condition: Unknown
Due 5 March 1999
Resolved 5 March 1999
Navigation
Issued 9 October 1996
Resolved
PROVIDE FIXED STORAGE TANK FOR STEERING GEAR HYDRAULIC SYSTEM IN ACCORDANCEWITH SOLAS CHAP II-1 REG 29 (12.3). COMPLETE PRIOR TO NEXT U.S. PORT CALL FROM A FOREIGN PORT.
Condition: Unknown
Due 11 March 1997
Resolved 11 March 1997
Navigation
Issued 9 October 1996
Resolved
MAKE PERMANENT REPAIRS TO THE #2 RADAR UNIT PRIOR TO DEPARTURE.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 24 July 1995
Resolved
REPAIR,RENEW, OR REPLACE PINHOLE IN FIREMAIN ON STARBOARD SIDE BETWEEN #3 AND #4 CARGO HOLD IN ACCORDANCE WITH SOLAS 74 AMENDED II-2/21. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Navigation
Issued 13 March 1994
Resolved
Chart No. 11512 was an 1986 chart with no correction.
Condition: Unknown
Due 13 March 1994
Resolved 16 March 1994
Navigation
Issued 13 March 1994
Resolved
Tidal Current Table was out dated (1991) with no corrections.
Condition: Unknown
Due 13 March 1994
Resolved 16 March 1994
Navigation
Issued 5 December 1989
Resolved
VSL'S MASTER GYROCOMPASS WAS NOT OPERATING PROPERLY PRIOR TO ENTERING A U.S. PORT,
Condition: Unknown
Due 5 December 1989
Resolved 5 December 1989
Navigation
Issued 13 August 1987
Resolved
33CFR164.33(A)(2)(I) THE COAST PILOT VOL. 5 WAS UNCORRECTED.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Documentation
Issued 13 August 1987
Resolved
33CFR151.25(H) ENTRIES IN THE OIL RECORD BOOK PART I (MACHINERY SPACE OPER-ATIONS) NOT SIGNED BY THE PERSON IN CHARGE.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Documentation
Issued 13 August 1987
Resolved
33CFR155.720 OIL TRANSFER PROCEDURES FOR BUNKER OPERATIONS INCOMPLETE.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Navigation
Issued 13 August 1987
Resolved
33CFR164.11(Q) THE TESTS REQUIRED BY 33CFR164.25 WERE NOT CONDUCTED AND RECORDED IN THE VESSEL'S LOG.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987
Navigation
Issued 13 August 1987
Resolved
33CFR164.33(A)(1)(II) THE HOUSTON SHIP CHANNEL CHARTS 11324, 11327, 11328 AND 11329 WERE UNCORRECTED.
Condition: Unknown
Due 13 August 1987
Resolved 13 August 1987