Records from 1984 to 2002. Most recent: operational control imposed, 1 May 2002.
Inspection history · 20
30 April 2002
MARPOL Annex I Examination · Uninspected Other
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1609684
17 April 2001
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 289212
12 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 145582
9 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 288968
14 December 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 457222
24 July 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 331652
26 June 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 331175
6 May 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 330235
7 January 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 500777
26 November 1988
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 536171
6 May 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 323159
25 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 487325
15 June 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 316774
13 January 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 460006
23 June 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 309739
16 April 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 523274
6 October 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 462555
11 March 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300818
7 November 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 532492
9 September 1984
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 297830
Fire Fighting
Issued 7 May 2002
No resolution recorded
Renew main space CO2 Alarms to satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Lifesaving
Issued 7 May 2002
No resolution recorded
Renew port and starboard lifeboat ladders to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2002 — due date passed with no resolution recorded
Lifesaving
Issued 7 May 2002
No resolution recorded
Renew stbd lifeboat wood blocks as needed to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 7 May 2002
No resolution recorded
Make repairs to fire main doublers under port lifeboat to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Pollution Prevention/Response
Issued 7 May 2002
No resolution recorded
Provide containment at the aft lube oil station to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 7 May 2002
No resolution recorded
Make repairs to the leaky fire station below the starboard lifeboat to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 7 May 2002
No resolution recorded
Provide fire hoses iaw SEC.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2002 — due date passed with no resolution recorded
Deck/Cargo
Issued 7 May 2002
No resolution recorded
Renew support wires for forward cargo mast to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Deck/Cargo
Issued 7 May 2002
No resolution recorded
Renew deck brackets for mast support wires to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Fire Fighting
Issued 7 May 2002
No resolution recorded
Make repairs to firemain doubler iwo port anchor windlass to the satisfaction of class.
Action required: 15 - Rectify deficiencies by next port
Due 7 May 2002 — due date passed with no resolution recorded
Lifesaving
Issued 7 May 2002
No resolution recorded
Make repairs to stbd lifeboat engine to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2002 — due date passed with no resolution recorded
Lifesaving
Issued 7 May 2002
No resolution recorded
Make repairs to stbd lifeboat falls to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Due 7 May 2002 — due date passed with no resolution recorded
Documentation › Certificates/Documents
Issued 30 April 2002
No resolution recorded
Provide flag acceptance of officer's certificates and STCW 95 endorsements.
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 30 April 2002
No resolution recorded
Make permanent repairs to the public sewage system.
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 30 April 2002
No resolution recorded
Exchange ship's service filters for running water.
Action required: 17 - Rectify deficiencies prior to departure
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 30 April 2002
No resolution recorded
Repair all ship's self actuating door closure mechanisms.
Action required: 17 - Rectify deficiencies prior to departure
Engineering
Issued 30 April 2002
No resolution recorded
Repair all leaks on fuel oil settling/day tanks and associated valve assemblies, remove all oil under settling/daytanks and replace oil saturated lagging iwo settling/daytanks.
Action required: 17 - Rectify deficiencies prior to departure
Engineering
Issued 30 April 2002
No resolution recorded
Make permanent repairs to the soft patch on the ballast line located in the fwd main space.
Action required: 17 - Rectify deficiencies prior to departure
Engineering
Issued 30 April 2002
No resolution recorded
Make permanent repairs to the cooling water leak on the #3 SSG. LEGACY COMPONENT DESC: SSG
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety
Issued 30 April 2002
No resolution recorded
Remove freon from main space.
Action required: 17 - Rectify deficiencies prior to departure
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 April 2002
No resolution recorded
Provide proper containment to the #3 gas oil line.
Action required: 703 - Prior to bunkering operations
Accommodation/Occupational Safety
Issued 30 April 2002
No resolution recorded
Fix all hydraulic leaks in forcastle iwo hydraulic tank and associated valves.
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety
Issued 30 April 2002
No resolution recorded
Remove toilet assembly from main space and permanently secure discharge line to MSD.
Action required: 17 - Rectify deficiencies prior to departure
Accommodation/Occupational Safety
Issued 30 April 2002
No resolution recorded
Fix hole in overhead iwo A/C flat.
Due 30 May 2002 — due date passed with no resolution recorded
Engineering
Issued 30 April 2002
No resolution recorded
Make permanent repairs to the soft patch in the sewage line.
Action required: 17 - Rectify deficiencies prior to departure
Pollution Prevention/Response
Issued 30 April 2002
No resolution recorded
Remove all oil in bilges.
Action required: 17 - Rectify deficiencies prior to departure
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 April 2002
No resolution recorded
Provide proper containment to the lube oil line.
Action required: 703 - Prior to bunkering operations
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 30 April 2002
No resolution recorded
Provide proper containment to the sludge line.
Action required: 703 - Prior to bunkering operations
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 30 April 2002
No resolution recorded
Provide fixed fire fighting system for paint locker starboard side, subject to administration.
Action required: 705 - Other - as specified
Due 30 May 2002 — due date passed with no resolution recorded
Fire Fighting › Fire Pumps
Issued 30 April 2002
No resolution recorded
Prove proper operation of the emergency fire pump for volumetric discharge.
Action required: 17 - Rectify deficiencies prior to departure
Operations/Management › Drills/Instruction › Fire
Issued 30 April 2002
No resolution recorded
Conduct satisfactory fire drill.
Action required: 17 - Rectify deficiencies prior to departure
Operations/Management › Drills/Instruction › Abandon Ship
Issued 30 April 2002
No resolution recorded
Conduct satisfactory abandon ship drill.
Action required: 17 - Rectify deficiencies prior to departure
Documentation
Issued 17 April 2001
Resolved
Officers do not have Flag State-issued licenses (Panama). Provide proof of compliance in accordance with STCW regulations prior to departure from Portof Houston._x001C_
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 9 April 2001
Resolved
EXCESSIVE LEAKAGE FROM M/E #2 CYLINDER FUEL INJECTOR. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 11 April 2001
Resolved 12 April 2001
Documentation
Issued 9 April 2001
Resolved
SHIP'S OFFICERS DO NOT HOLD VALID FLAG STATE LICENSES (PN).
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 9 April 2001
Resolved
#1 GENERATOR HAS TEMP. PATCH AND HOLE ON S/W SUPPLY PIPING.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Accommodation/Occupational Safety
Issued 9 April 2001
Resolved
TEMPORARY RUBBER BY-PASS HOSES FOR REFER PUMP. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Engineering
Issued 9 April 2001
Resolved
#2 L/O PURIFIER INOP. PARTS REMOVED FOR USE IN #1 L/O PURIFIER. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Documentation
Issued 9 April 2001
Resolved
PROVIDE CURRENT COPIES OF APPLICABLE C.F.R. REGS.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Fire Fighting
Issued 9 April 2001
Resolved
EMERGENCY FIRE PUMP COULD NOT PROVIDE PRESSURE AFTER 15 MINUTES OF OPERATION WITH SHIP IN LOADED CONDITION. PROVE PROPER OPERATION OF PUMP TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 11 April 2001
Resolved 12 April 2001
Documentation
Issued 9 April 2001
Resolved
DISCHARGE OF OIL PLACARD MISSING.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Engineering
Issued 9 April 2001
Resolved
EXCESSIVE LEAKAGE/OIL BUILD UP ON #1 L/O PURIFIER. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 11 April 2001
Resolved 12 April 2001
Accommodation/Occupational Safety
Issued 9 April 2001
Resolved
HOSPITAL SPACE NOT SANITARY AND BEING USED FOR STORAGE.
Condition: Unknown
Due 15 April 2001
Resolved 12 April 2001
Accommodation/Occupational Safety
Issued 9 April 2001
Resolved
GALLEY VENTILATION FOR RANGE MISSING GREASE TRAP SCREEN.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Lifesaving
Issued 9 April 2001
Resolved
EPIRB BATTERY EXPIRES WITHIN THE MONTH.
Condition: Unknown
Due 11 April 2001
Resolved 12 April 2001
Fire Fighting
Issued 9 April 2001
Resolved
CREW UNABLE TO DEMONSTRATE PROPER FIRE DRILL IN TWO ATTEMPTS.
Condition: Unknown
Due 12 April 2001
Resolved 12 April 2001
Navigation
Issued 9 April 2001
Resolved
SHIP'S GYRO COMPASS INOP.
Condition: Unknown
Due 11 April 2001
Resolved 12 April 2001
Engineering
Issued 9 April 2001
Resolved
#3 GENERATOR MISSING COOLING WATER PUMP AND HAS TEMP COOLING WATER SUPPLY FROM STEAM CONDENSOR PUMP. REPAIR TO THE SATISFACTION OF CLASS.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Navigation
Issued 26 June 1989
Resolved
33CFR164.33(A)(2)(II) AUTHORITY: 33USC1223(A)(3) PENALTY CITE: 33USC1232(A)(1)
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Navigation
Issued 26 June 1989
Resolved
33CFR164.33(A)(2)(I) AUTHORITY:33USC1223(A)(3) PENALTY CITE: 33USC1232(A)(1)
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Documentation
Issued 26 June 1989
Resolved
49CFR176.30(B) AUTHORITY:49USC1804(A) PENALTY CITE: 49USC1809(A)(1)
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Documentation
Issued 26 June 1989
Resolved
49CFR176.30(A)(3) AUTHORITY: 49USC1804 PENALTY CITE: 49USC1804
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Documentation
Issued 26 June 1989
Resolved
49CFR176.30(A) AUTHORITY: 49USC1804(A) PENALTY CITE: 49USC1809(A)(1)
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Navigation
Issued 26 June 1989
Resolved
33CFR164.33(A)(1)(II) AUTHORITY: 33USC1223(A)(3) PENALTY CITE: 33USC1232(A)(1)
Condition: Unknown
Due 26 June 1989
Resolved 26 June 1989
Engineering
Issued 9 September 1984
Resolved
THE VESSEL DID NOT HAVE A RECORD OF THE DATE AND RESULTS OF THE TESTS REQUIRED BY 33CFR156.170
Condition: Unknown
Due 9 September 1984
Resolved 9 September 1984