Records from 1984 to 2009. Most recent: inspection, 2 July 2009.
Inspection history · 42
2 July 2009
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3521466
14 September 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3324649
9 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 3321046
17 June 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3239407
21 September 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3063045
28 January 2007
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 2862951
28 January 2007
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2862985
9 January 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2853119
8 January 2007
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2852137
15 May 2006
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2649512
22 March 2005
MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS III Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2314666
29 June 2004
NPV Safety Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2114819
25 June 2004
ISPS II Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 2110386
30 March 2004
Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2050201
12 January 2004
Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1982367
2 October 2003
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1913509
28 July 2003
Re-Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1860032
18 November 2002
Deficiency Check · Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1707191
14 November 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1706306
29 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 276344
24 March 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 9906
4 November 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 422304
27 July 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 40548
27 May 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 684884
26 May 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 416411
17 November 1997
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 454803
3 July 1997
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 405226
7 January 1997
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 398961
12 December 1995
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 385683
7 July 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 380420
5 December 1994
Control Verification
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1142630
9 November 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 340404
23 August 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 525990
13 January 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 334565
18 August 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 463066
8 May 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 330335
4 February 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 457007
10 January 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 327911
25 July 1988
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 539012
5 February 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 320862
17 September 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 311441
1 November 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 298758
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 17 June 2008
Resolved
Numerous dates for crew imbarkation were submitted incorrectly on the NOA, additionally 01 ID number and two crew names were submitted incorrectly, vessel is to submit an update to NOA prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Agent resubmitted proper NOA
Operations/Management › Ballast Water Managment › Submission of Report
Issued 17 June 2008
Resolved
Vessel failed to submit a ballast water report within the time limits given in 33CFR151.2041, vessel is to submit a ballast water report to NBIC prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Rcvd confirmation from vessel that NBIC Report was resubmitted
Engineering › Fuel Oil Service System › Piping
Issued 17 June 2008
Resolved
Fuel oil purifier fuel elbow on top of bowl is missing, part has been ordered, vessel to make repair to satisfaction of class society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 July 2008
Resolved 9 September 2008
Resolution: Part was ordered and repairs were made to satisfactory.
Engineering › Fuel Oil Service System › Piping
Issued 17 June 2008
Resolved
Fill line between strainers on end bulkhead in fuel oil purifying room for fuel oil has been leaking steadily for unknown time, vessel to make permanent repairs to satisfaction of class society.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 July 2008
Resolved 21 June 2008
Resolution: Received report from class attesting to the repair of piping on strainer.
Engineering › Fuel Oil Service System › Filter
Issued 17 June 2008
Resolved
Fuel oil filter inboard #3 generator is leaking fuel oil, excessive accumilation located in bilge below, vessel to make permanent repairs and clean fuel oil in bilge below to satisfaction of class society.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Received report from class attesting to the repair of filter and operational test of #3 generator.
Engineering › Bilge Water Management System › Not Operational
Issued 17 June 2008
Resolved
Bilge alarm on port side of engine room- fwd adjacent to transverse bulkhead is not working correctly, vessel to make repairs to satisfaction of class society.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Received report from class attesting to the repair and operational test of bilge alarm in question.
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 17 June 2008
Resolved
Smoke detector in fuel oil purifier room is not properly secured, vessel to make permanent repairs to satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 20 July 2008
Resolved 21 June 2008
Resolution: Received report from class attesting to the repair of the smoke detector in question.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 17 June 2008
Resolved
Vessel has no means of safely testing smoke/fire alarms, vessel to acquire proper testing equipment to satisfaction of class society.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Received report from class attesting to the acquisition of 02 smoke detector test spray. Additionally class has issued a condition due to the loop 3 having a re-ocurring self activation.
Fire Fighting › Structural - Main Vertical Zones › General
Issued 17 June 2008
Resolved
Found numerous doors throughout stairwell latched open, latched doors are not I.A.W fire plan, vessel to close automatic closing doors prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 June 2008
Resolution: Received report from class attesting to the closure of doors in question, additionally tested automatic closure devices and found all to be operational.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 15 May 2006
Resolved
vessel could not bring emergency fire pump pressure up to adequet fire fighting capabilities. Request Flag State Report
Action required: 705 - Other - as specified
Due 15 May 2006
Resolved 15 May 2006
Resolution: Recieved Class Report. Valve on the emergency fire pump was partially open.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 22 March 2005
Resolved
Emergency Fire Pump could not take suction and was not ready for immediate use. Inspection of the hydraulic system indicated a low fluid level.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 March 2005
Resolved 22 March 2005
Resolution: Crew replenished system with approximately 20 liters of hydraulic oil. Emergency Fire Pump was re-energized, able to obtain suction and provide adequate pressure.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 29 June 2004
Resolved
Vessel missing required placards in engine room, especially near oily water seperator.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 30 July 2004
Resolved 8 July 2004
Resolution: Vessel placed placard in conspicuous location in engineroom.
Navigation › Collision/Grounding Avoidance
Issued 12 January 2004
Resolved
Properly repair navigation lights on ship's mast. Navigation light was damged becuase of heavy weather sustained in transit. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 13 January 2004
Resolved 14 January 2004
Deck/Cargo › Cargo Stowage
Issued 28 July 2003
Resolved
No.2 No.3 and No.5 hydraulic control valves for cargo hatch covers have minor leaks.
LEGACY COMPONENT DESC: Hatch Cover Hydraulic Control Valves
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 2 October 2003
Resolution: No. 2, No. 3, and No. 5 hydraulic control valves for cargo hatch covers were repaired to the satisfaction of the Administration. Defs cleared.
Deck/Cargo › Cargo Stowage
Issued 28 July 2003
Resolved
Main hydraulic pipe for all cargo hatch covers has a soft patch by the No.1 cargo hold, starboard side.
LEGACY COMPONENT DESC: Cargo Hatch Cover Hydraulic Supply Pipe
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 July 2003
Resolved 28 July 2003
Resolution: Welder cropped out the section with the soft patch and replaced it with new pipe.
Deck/Cargo › Mooring/Anchoring
Issued 28 July 2003
Resolved
The anchor windlass hydraulic supply pipe three-way valve has a minor leak coming from its stem seal.
LEGACY COMPONENT DESC: Anchor Windlass
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 2 October 2003
Resolution: The anchor windlass hydraulic supply pipe three-way valve was repaired to the satisfaction of the Administration. Def cleared.
Operations/Management › FireFighting
Issued 28 July 2003
Resolved
Outstanding condition of class issued for the fire detection system being inoperative. The engine room shall be manned 24 hours. Outstanding condition exist until 08 Aug 03.
LEGACY COMPONENT DESC: Fire Detection System
Condition: Unknown
Action required: 705 - Other - as specified
Due 8 August 2003
Resolved 2 October 2003
Resolution: Repaired to the satisfaction of the Administration. Def cleared.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 July 2003
Resolved
Generator No. 2 has excessive leaks coming from the body of the No. 3 fuel pump. The generator must not be used until repairs are made.
LEGACY COMPONENT DESC: Pump, High Pressure (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: No.3 fuel pump was replaced and tested to the satisfaction of class.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 July 2003
Resolved
Generator No. 3 has a noteworthy oil leak coming from the three-way valve on top of the lube oil cooler.
LEGACY COMPONENT DESC: Lube Oil Cooler
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: The gaskets were replaced and the system was tested to the satisfaction of class.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 28 July 2003
Resolved
The main engine has a noteworthy cooling water leak on the No. 5 cylinder.
LEGACY COMPONENT DESC: Cylinder Head
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: The cylinder head hold down bolts were tightened and the system was tested to the satisfaction of class.
Engineering › Lubricating Oil Service System
Issued 28 July 2003
Resolved
The main engine lube oil cooler has two temporary weld patches on the cooling water outlet piping. LEGACY COMPONENT DESC: Cooler
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: An elbow 165mm diameter by 600mm in length and a straight section of pipe 165mm diameter by 600mm in length was replaced and pressure tested to the satisfaction of class.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 July 2003
Resolved
The local RPM indicator on the No. 2 generator is not working.
LEGACY COMPONENT DESC: Local RPM Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: Local RPM indicator was replaced and tested to the satisfaction of class.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 28 July 2003
Resolved
The local RPM indicator on the No. 3 generator is not working.
LEGACY COMPONENT DESC: Local RPM Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: Local RPM indicator was replaced and tested to the satisfaction of class.
Engineering › Compressed Air System (start air)
Issued 28 July 2003
Resolved
The No. 2 start air compressor has a cooling water leak on the outlet piping.
LEGACY COMPONENT DESC: Cooling Water Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: Cooling water leak was repaired to the satisaction of class.
Engineering › Steam Boiler (auxiliary/waste heat)
Issued 28 July 2003
Resolved
The auxiliary boiler's door closed safety switch is disconnected.
LEGACY COMPONENT DESC: Access Door Safety Switch
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: The door cover was replaced and checked to the satisfaction of class.
Engineering › Fuel Oil Storage/Transfer System
Issued 28 July 2003
Resolved
The housekeeping in the separator room needs attention. Fuel oil has accumulated under the flat from a prior leak.
LEGACY COMPONENT DESC: Seperator Room
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 August 2003
Resolved 29 July 2003
Resolution: Separator room was cleaned to the satisfaction of class.
Electrical › Electrical Distribution System (service)
Issued 18 November 2002
Resolved
The 220 volt system has a 1.6 ohm ground. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 1 generator has a rubber hose and hose clamps being used for a 3.5 bar pressure fuel oil supply line to the injection pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 1 generator has a noteworthy oil leak from governor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 1 generator's #6 cylinder has a noteworthy jacket water leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 2 generator has an excessive jacket water leak from the # 4 cylinder and a noteworthy jacket water leak on the # 5 cylinder.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 2 generator has a noteworthy oil leak from the governor.
LEGACY COMPONENT DESC: Governor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No. 2 generator has a notable fuel oil leak from valve on main feed line to injection pump from filter housing.
LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Diesel Engine (auxiliary)
Issued 18 November 2002
Resolved
The No 2 generator's #4, #5, and # 6 f/o lines to the injection pumps have leaks.
LEGACY COMPONENT DESC: Injector (fuel injection)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Engineering › Freshwater System (intermediary cooling)
Issued 18 November 2002
Resolved
The feed water line for the boiler has a hole and 5 soft patches consisting of a band clamp and rubber.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2002
Resolved 20 November 2002
Resolution: Cleared by Bureau Veritas class report dated 20 Nov 02.
Fire Fighting
Issued 29 March 2000
Resolved
FIRE PUMP HAS CEMENT PATCH AND WASTED WELD ON GAUGE LINE. LEAKING WATER.
Condition: Unknown
Due 29 April 2000
Resolved 2 October 2003
Resolution: Repaired to the satisfaction of the Administration. Def cleared.
Fire Fighting
Issued 4 November 1998
Resolved
The firemain piping in the engineroom, between the sea chest and main fire pump, was cracked. About 1/2 of the pipes circumference was cracked. During a test of the firemain it leaked approx. 100 gallons a minute. _x001C_ (SOLAS 74 Ch.I Reg.11)
Condition: Unknown
Due 6 November 1998
Resolved 5 November 1998
Lifesaving
Issued 4 November 1998
Resolved
The cooling units in the refrigerator/freezers had uncovered/exposed fans with no guards. (SOLAS 74 Ch.II Reg.26)_x001C_
Condition: Unknown
Due 6 November 1998
Resolved 5 November 1998
Electrical
Issued 4 November 1998
Resolved
The emergency light for the starboard lifeboat was improperly wired. Wiring was exposed and had temporary connections. (SOLAS 74 Ch.II Reg.45)
Condition: Unknown
Due 6 November 1998
Resolved 5 November 1998
Deck/Cargo
Issued 4 November 1998
Resolved
The hydraulic oil piping for the cargo hatch covers and deck winches was leaking. (SOLAS Ch.I Reg.11)
Condition: Unknown
Due 6 November 1998
Resolved 5 November 1998
Documentation
Issued 4 November 1998
Resolved
Safety Equipment certificate was improperly dated. The certificate was issued on 10Oct98 and expired on 09Mar98. (SOLAS 74 Ch.I Reg.12)
Condition: Unknown
Due 30 March 2000
Resolved 30 March 2000
Navigation
Issued 26 May 1998
Resolved
The vessel operator, Ocean Bulk Maritime S.A., failed to provide the_x001C_ vessel with a NOAA 11370 or foreign equivalent chart, required for the areatransited. The vessel transited from MM105 to MM170 of the Lower Mississippi River without a chart for the area.
Condition: Unknown
Due 27 May 1998
Resolved 27 May 1998
Accommodation/Occupational Safety
Issued 12 December 1995
Resolved
MISSING U.S. COAST GUARD APPROVAL NUMBER FOR THE MARINE SANITATION DEVICE. (SEWAGE TREATMENT) 33 CFR 159.7
Condition: Unknown
Due 12 January 1996
Resolved 18 December 1995
Electrical
Issued 5 December 1994
Resolved
REPLACE MISSING LIGHT COVER INSIDE PAINT LOCKER.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Engineering
Issued 5 December 1994
Resolved
CLEAN FUEL VENT FLAME SCREENS.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Fire Fighting
Issued 5 December 1994
Resolved
REPLACE THE 2 HOLED FIRE HOSES.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Navigation
Issued 5 December 1994
Resolved
REPLACE DIM LIGHT BULB IN ALDIS.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Deck/Cargo
Issued 5 December 1994
Resolved
TIGHTEN CONNECTION ON LEAKING HATCH COVER HYDRAULIC LINE IN WAY OF CARGO HOLD #3 STBD SIDE.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Navigation
Issued 9 November 1990
Resolved
33 CFR 164.11(r) VESSEL ENTERED THE PORT OF CORPUS CHRISTI TX. WITH AN INOPERATIVE PRIMARY RADAR WHICH IS REQUIRED ON THIS VESSEL BY 33 CFR 164.35(a). EQUIPMENT WAS REPORTED TO BE INOPERATIVE BY MASTER, VESSEL WAS ISSUED LTR OF DEV. TO ENTER PORT, CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 November 1990
Resolved 9 November 1990
Navigation
Issued 8 May 1989
Resolved
33CFR164.35(A) THE VESSEL ENTERED THE PORT OF CORPUS CHRISTI, TX WITH AN INOPERATIVE SECONDARY RADAR 33CFR164.11(R). LETTER OF DEVIATION REQUESTED AND RECEIVED. SECONDARY RADAR WAS REPAIRED PRIOR TO DEPARTURE.
Condition: Unknown
Due 8 May 1989
Resolved 8 May 1989
Navigation
Issued 17 September 1986
Resolved
THE VESSEL WAS OPERATED WITHOUT THE CHARTS REQUIRED BY 33CFR164.33(A)(I)
Condition: Unknown
Due 17 September 1986
Resolved 17 September 1986
Documentation
Issued 17 September 1986
Resolved
THE DATE AND RESULTS OF THE OIL TRANSFER PIPING TESTS AS REQUIRED BY 33CFR156.170 WERE NOT LOGGED
Condition: Unknown
Due 17 September 1986
Resolved 17 September 1986
Navigation
Issued 17 September 1986
Resolved
THE "PRIOR TO ENTRY" TESTS REQUIRED BY 33CFR164.25 WERE NOT LOGGED
Condition: Unknown
Due 17 September 1986
Resolved 17 September 1986
Navigation
Issued 17 September 1986
Resolved
THE VESSEL WAS OPERATED WITHOUT THE CHARTS REQUIRED BY 33CFR164.33(A)(1) (II)
Condition: Unknown
Due 17 September 1986
Resolved 17 September 1986
Navigation
Issued 17 September 1986
Resolved
VESSEL WAS OPERATED WITHOUT THE CURRENTLY CORRECTED COAST PILOT REQUIRED BY 33CFR164.33(A)(2)(I)
Condition: Unknown
Due 17 September 1986