MAURY USCG vessel records Sign in
← All vessels

OSIOS DAVID II

OSIOS DAVID II is a 1982 freight ship. The Coast Guard has recorded 39 inspections since 1986, most recently in October 2007, along with 37 deficiencies — 1 with no resolution recorded — and 8 operational controls.

Records from 1986 to 2007. Most recent: inspection, 8 October 2007.

Built
1982
Last inspected
8 October 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8103195 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227118
Flag
MALTA
—
Maury page id
psix-227118

Inspections, by type

…with no type recorded28
…past their stated due date1
Years with a record 16 calendar years (1986–2007)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9474 - Convention (Subpart B), Net Ton
14330 - Convention (Subpart B), Gross Ton
29738 - Displacement, Ton
23791 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 39

8 October 2007 Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3075395
3 January 2007 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2849781
1 January 2007 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2848761
10 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2600011
3 March 2006 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2595363
18 January 2006 ISPS I Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 2568734
15 January 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2567242
13 January 2006 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2566281
20 June 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2396341
3 June 2005 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2377779
12 October 2004 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2218427
10 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2218147
9 October 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2217500
12 April 2004 Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2042843
10 February 2004 Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2003676
5 February 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2002405
30 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2002404
29 January 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1997241
15 August 2002 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1659487
4 March 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1490285
26 June 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 291331
24 May 2001 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 290358
26 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 281491
7 February 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 274829
14 January 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 273754
31 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374823
21 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 374274
9 August 1993 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 360078
6 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 360136
28 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 675007
27 July 1993 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 359858
14 June 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 344363
21 November 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 436627
21 May 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 337244
19 October 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 471474
30 March 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 329243
9 March 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 321733
27 January 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314002
3 December 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 313020

Deficiency record · 37

Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 8 October 2007 Resolved
The vessel does not have a record of hydrostatic testing of the fuel oil and lube oil transfer system as required by 33 CFR 156.170. Provide proof of hydrostatic testing to the satisfaction of the attending Coast Guard Marine Inspector prior to conducting bunkering operations in United States waters.
Action required: 703 - Prior to bunkering operations
Due 9 October 2007
Resolved 10 October 2007
Resolution: Received certification of fuel/lube oil hydrostatic testing.
Construction/Loadline › Structures › Deck Plating
Issued 3 June 2005 Resolved
Bulwark brackets located by Hatches #3 and #4 wasted and cracked. Structural deficiency. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Engineering › Freshwater System (air cooling) › Piping
Issued 3 June 2005 Resolved
Patches on two Air Conditioning cooling lines in AC Room. Patches can fail resulting in a flooded space. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Construction/Loadline › Penetrations › Valve Flange
Issued 3 June 2005 Resolved
Concrete around deck valve by #1 top side tank, port side. Class needs to address the existence and need of the concrete for the valve. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Fire Fighting › Fire Main › Condition
Issued 3 June 2005 Resolved
Fire main leak on deck by hold #4. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Deck/Cargo › Ballast › Piping
Issued 3 June 2005 Resolved
Patch on overboard ballast line in engine room. Patch can fail resulting in a flooded space. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 3 June 2005 No resolution recorded
Bulkhead between engine room and crew wash space wasted. Bulkhead is a fire boundary for engine room (machinery spaces of category A). SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005 — due date passed with no resolution recorded
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 3 June 2005 Resolved
One of two fire suits is in poor condition. The outer silver reflective material has peeled away in significant spots. Crew will apply temporary fix on fire suit until a new one is obtained.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired all of the cracks under the Masters direction. Inspection of the repairs was made and accepted by Class.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 3 June 2005 Resolved
Automatic door self-closing arm devices for the galley and engine room doors are not closing the doors. This deficiency prevents maintaining a fire-resisting boundary.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 17 June 2005
Resolved 16 June 2005
Resolution: The Crew repaired to the doors under the Masters direction. Inspection of the repairs was made and accepted by Class.
Documentation › Logs/Records › Oil Record Book
Issued 3 June 2005 Resolved
Oil record book missing date and responsible person's signature. Such entries are required for proper record keeping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Resolution: Master and chief engineer added missing dates and signatures to the oil record book. They were educated on the proper record keeping while they hold responsibility for the oil record book.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 3 June 2005 Resolved
Oil on deck in hatchcover pump room and steering flat. Oily conditions, along with poor general housekeeping, creates a hazardous condition. SOLAS, Ch. I, Reg. 11: Maintenance of conditions after survey.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Resolution: Crew performed housekeeping and cleaning of hatchcover pump room and steering flat.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 3 June 2005 Resolved
Garbage management and record keeping were not maintained properly. Recording of oily rags incineration was not in garbage log. Master's signature was not on garbage plan. Garbage not properly segregated according to garbage plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Resolution: Garbage management and record keeping maintained properly. Recording of oily rags incineration in garbage log. Master signed garbage plan. Garbage segregated acccording to garbage plan.
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 3 June 2005 Resolved
Ballast Water Reporting Form was not properly completed, signed, and submitted to the authorities.
Condition: Unknown
Action required: 705 - Other - as specified
Due 3 June 2005
Resolved 3 June 2005
Resolution: Master and [name withheld] properly completed, signed, and submitted Ballast Water Reporting Form.
Pollution Prevention/Response › Prevention Equipment
Issued 10 February 2004 Resolved
OWS has multiple leaks around it's front and back hatches LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Due 10 February 2004
Resolved 10 February 2004
Resolution: Tightened bolts on hatches
Engineering › Fuel Oil Service System
Issued 10 February 2004 Resolved
Main engine is leaking at the fuel oil filter of the service tank LEGACY COMPONENT DESC: Filter
Condition: Improper/Lack of Maintenance
Due 10 February 2004
Resolved 10 February 2004
Resolution: replaced filter
Electrical › Electric Generation Source (service)
Issued 10 February 2004 Resolved
Service generators #1,2,3 have multiple leaks on their cooling water pipes LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 10 February 2004
Resolved 10 February 2004
Resolution: tightened hose connected to the cooling water pipes
Engineering
Issued 10 February 2004 Resolved
The softpatch on the seawater service pump needs permanent repairs LEGACY COMPONENT DESC: Pump
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2004
Resolution: Verified no soft patches found.
Electrical › Electric Generation Source (service)
Issued 10 February 2004 Resolved
#1 and #3 service generator's rpm gauges need repaired/ replaced LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 April 2004
Resolution: No.1 and No.2 service generator rpm gauges were replaced.
Lifesaving › Inflatable Liferafts
Issued 4 March 2002 Resolved
Reconfigure liferaft stowage, where one painter was not permanently attatched to the ship. SOLAS 74 amd III-29 LEGACY COMPONENT DESC: Painter
Action required: 705 - Other - as specified
Due 4 March 2002
Resolved 4 March 2002
Resolution: Master ensured proper liferaft stowage by permanently attatching liferaft painter to the ship.
Documentation › Safety/Response Plans/Programs
Issued 28 February 2002 Resolved
Update the fire control plan symbols. SOLAS 74 amd II-2/20, IMO Res. A.654 (16). Complete the above item prior to next U.S. port after sailing foreign, to the satisfaction of class. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 August 2002
Resolution: Fire control symbols updated.
Accommodation/Occupational Safety
Issued 24 May 2001 Resolved
TOILET IN HOSPITAL RESTROOM WAS NOT WORKING DUE TO A MISSING WATER SUPPLY LINE.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Deck/Cargo
Issued 26 August 2000 Resolved
The starboard aft gooseneck diesel oil fitting was partially worn away.
Condition: Unknown
Due 25 May 2001
Resolved 25 May 2001
Engineering
Issued 26 August 2000 Resolved
Flame screen missing on number two starboard diesel oil gooseneck.
Condition: Unknown
Due 27 June 2001
Resolved 27 June 2001
Documentation
Issued 14 January 1999 Resolved
PROVIDE LIGHTLIST ONBOARD AND FAX RECEIPT TO NEXT USCG OFFICE.
Condition: Unknown
Due 15 February 2000
Resolved 15 February 2000
Fire Fighting
Issued 21 January 1995 Resolved
Remove hold back on door from engineroom to steering room. SOLAS II-2 47(2). Correct prior to departure.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 21 January 1995 Resolved
Properly attach painters from life rafts to ship. SOLAS III/29. Correct prior to departure.
Condition: Unknown
Due 21 January 1995
Resolved 24 January 1995
Fire Fighting
Issued 21 January 1995 Resolved
Provide adequate fixed firefighting system for paint locker. SOLAS II- 2/18(7). Correct prior to returning to a U.S. port.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 21 January 1995 Resolved
Replace retro reflective tape on lifefloats (liferings). SOLAS III/7.1 Correct prior to departure.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Fire Fighting
Issued 21 January 1995 Resolved
Replace automatic closure on door to steering gear room. SOLAS II-2/46(1). Correct prior to departure.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Lifesaving
Issued 21 January 1995 Resolved
Provide retro reflective tape on life jackets in engineroom. SOLAS III/7. Correct prior to departure.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Fire Fighting
Issued 21 January 1995 Resolved
Replace automatic closure device on door to engineroom from accomodations. SOLAS II-2/46(1). Correct prior to departure.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Navigation
Issued 21 January 1995 Resolved
Provide current copy of U.S. Coast Pilot. 33 CFR 164.33. Correct prior todeparture.
Condition: Unknown
Due 31 January 1995
Resolved 31 January 1995
Unknown
Issued 27 July 1993 Resolved
CREW DISCHARGED GARBAGE MIXED WITH PLASTICS INTO THE SEA OR INTO THE U.S. WATERS.
Condition: Unknown
Due 24 January 1995
Resolved 24 January 1995
Navigation
Issued 21 May 1990 Resolved
CHART NO. 18523 NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Accommodation/Occupational Safety
Issued 21 May 1990 Resolved
MARINE SANITATION DEVICE OPERATING IMPROPERLY-BYPASSING SYSTEM.
Condition: Unknown
Due 21 May 1990
Resolved 21 May 1990
Documentation
Issued 3 December 1986 Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE MISSING CARGO INFORMATION, PROCEDURESFOR EMPTYING CONTAINMENT, DUTIES FOR TENDING MOORING LINES, AND PROCEDURES FOR TOPPING OFF.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986
Navigation
Issued 3 December 1986 Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ONBOARD.
Condition: Unknown
Due 3 December 1986
Resolved 3 December 1986

Ownership record