Records from 1985 to 2005. Most recent: inspection, 5 October 2005.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
5 October 2005
PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2508678
29 July 2002
Passenger/Freight Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1653694
25 October 1999
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 433804
2 September 1998
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 419800
18 August 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 406936
25 August 1996
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 394699
27 February 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 388248
22 December 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 386036
21 June 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 379754
13 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 368528
13 July 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1176039
8 January 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 537368
18 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 504861
3 January 1992
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 347908
16 December 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340885
10 October 1989
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 333001
15 October 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 312040
24 July 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 303103
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 October 2005
Resolved
Prove the proper operation of the oily water separator to the satisfaction of class. And an oil like substance was found on the OWS overboard valve. Also, both solenoid valves appear to be both open or closed at the same time when on should be open and the other closed. MARPOL 73/78 ANNEX I/16
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2005
Resolution: Fax from class society confirms proper working order.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 5 October 2005
Resolved
Prove the proper operation of the waste oil incinerator while burning waste oil to the satisfaction of class. the incinerator can only be started by placing a burning rag into the chamber. SOLAS 74/I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2005
Resolution: Fax from class society confirms proper working order.
Documentation › Certificates/Documents › IOPP Certificate
Issued 5 October 2005
No resolution recorded
Update the IOPP to include the F.O. and L.O. sludge tanks and any other tanks required to be listed on the IOPP. MARPOL 73/78 ANNEX I/17
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 5 October 2005
No resolution recorded
Immediately begin making engine room tank sounding recordings as required by STCW 95 VIII 58 AND 73.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Personnel › Training › Familiarization Training
Issued 5 October 2005
No resolution recorded
Update the new crew familiarization training IAW STCW 95 VI/I.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type 1
Issued 5 October 2005
No resolution recorded
Provide class approval for the modifications made to the MSD pumping system. SOLAS 74 I/II
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Engineering › Bilge Water Management System › Piping
Issued 5 October 2005
No resolution recorded
Provide class approval for the updated bilge piping arrangements and provide an updated bilge piping diagram. MARPOL 73/78 ANNEX I/4.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 5 October 2005
No resolution recorded
Repair the leaking reefer pipe in the meat reefer where there is a leak creating a slip hazard. SOLAS 74 I/II
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 5 October 2005
Resolved
Install a fixed fire fighting system for the cargo holds or provide an exemption certificate from the solas requirement. SOLAS 74 II-2/52
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 October 2005
Resolution: Fax of current Exemption certificate received.
Lifesaving › Inflatable Liferafts
Issued 29 July 2002
Resolved
CREW COULD NOT EASILY MOVE LIFE RAFTS FROM STOWAGE POSITION TO SIDE OF VESSEL LADDERS OBSTRUCTED PATH AND WAS TOO HEAVY. CLASS TO ADDRESS LEGACY COMPONENT DESC: Carriage Requirement
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 August 2002
Resolved 2 August 2002
Resolution: Stowage position moved to boat deck, port and stbd.
Electrical
Issued 25 October 1999
Resolved
Embarkation lights missing watertight covers and guards. Install new coversand guards prior to 25NOV99. SOLAS 74 11-1/27
Condition: Unknown
Due 25 November 1999
Resolved 28 July 2002
Resolution: CORRECTED BY PHIMS
Navigation
Issued 25 October 1999
Resolved
Aft steering ram seals leaking hydraulic fluid. Repair/renew prior to 25NOV99.SOLAS 74 11-1/29
Condition: Unknown
Due 25 November 1999
Resolved 28 July 2002
Navigation
Issued 25 October 1999
Resolved
Containments missing mechanical plugs.Provide plugs prior to 25NOV99 33CFR155
Condition: Unknown
Due 25 November 1999
Resolved 28 July 2002
Fire Fighting
Issued 25 October 1999
Resolved
No foam tank operating procedures posted. Post procedures by tank prior to 25NOV99. SOLAS 74 11-2/20
Condition: Unknown
Due 25 November 1999
Resolved 28 July 2002
Resolution: CORRECTED BY PHIMS
Electrical
Issued 18 August 1997
Resolved
Make permanent repairs to the wasted piping about the generator cooling pump prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Engineering
Issued 18 August 1997
Resolved
Make permanent repairs to the #2 main air compressor cooling line just aft of the pump prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/28
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Deck/Cargo
Issued 18 August 1997
Resolved
Make permanent repairs to all hydraulic leaks on main deck (note the port side of #2 hold & aft side of #6 hold) prior to return to a U. S. port._x001C_ _x001C_ 33 CFR 151.10.b
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Fire Fighting
Issued 18 August 1997
Resolved
Make permanent repairs to the two holes in the firemain located between number 4 & 5 cargo holds prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/52.b
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Construction/Loadline
Issued 18 August 1997
Resolved
Make permanent repairs to the holed garbage overboard chute (stbd, LL E/R) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 I/11
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Fire Fighting
Issued 18 August 1997
Resolved
Make fire control plan, located in main deck passage, clearly legible (planis fading) prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 amd II-2/20
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Accommodation/Occupational Safety
Issued 18 August 1997
Resolved
Make permanent repairs to the holed MSD tank prior to return to a U. S. port. _x001C_ _x001C_ 33 CFR 159.7
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Electrical
Issued 18 August 1997
Resolved
Remove or properly wire the heating lamps in the steering gear space for the hydraulic deck winch motors prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27.a.vi
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Lifesaving
Issued 18 August 1997
Resolved
PROVE CURRENT EPIRB BATTERY DATE. BATTERY IS NOT MARKED WITH EXPIRATION DATE. (SOLAS 74 amd VI/7.1.6)
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Lifesaving
Issued 18 August 1997
Resolved
Post the lifeboat lowering instructions at both lifeboat stations prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 III/19 & 38
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Fire Fighting
Issued 18 August 1997
Resolved
Remove the hold backs on the fire doors to the machinery & steering gear spaces prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/20
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Fire Fighting
Issued 18 August 1997
Resolved
Make permanent repairs to the fiberglass patch on the firefighting foam tank prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-2/7
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Engineering
Issued 18 August 1997
Resolved
Make permanent repairs to the main engine air box cooling line where patched with bondo prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/28
Condition: Unknown
Due 3 September 1998
Resolved 3 September 1998
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO NEXT U.S. PORT, REPAIR RAILS ON FORECASTLE DECK STARBOARD SIDE WHERE RUSTED.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO DEPARTURE, REPLACE STARBOARD RINGBOUY ON MAIN DECK MID SECTION.
Condition: Unknown
Due 23 December 1995
Resolved 28 December 1995
Engineering
Issued 22 December 1995
Resolved
PRIOR TO THE NEXT U.S. PORT, PROVIDE PROOF THAT BUNKER (TRANSFER) PIPING HAS BEEN TESTED TO 150% MAWP.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO DEPARTURE, REPLACE LIGHT ON AFT RING BOUY MAIN DECK.
Condition: Unknown
Due 23 December 1995
Resolved 28 December 1995
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO DEPARTURE, REPLACE ROTTED HOSES TO LIFEBOAT MANUAL BILGE PUMP.
Condition: Unknown
Due 23 December 1995
Resolved 28 December 1995
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO DEPARTURE, REPLACE LIGHT TO FOREPEAK RING BOUY.
Condition: Unknown
Due 23 December 1995
Resolved 28 December 1995
Lifesaving
Issued 22 December 1995
Resolved
PRIOR TO NEXT U.S. PORT, REPAIR RAILS STARBOARD SIDE AFT MAIN DECK.
Condition: Unknown
Due 27 February 1996
Resolved 27 February 1996
Lifesaving
Issued 21 June 1995
Resolved
IMPROPPER RING BOUYS ON BRIDGE WINGS, NOT 4KG._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Engineering
Issued 21 June 1995
Resolved
THREADED METAL PLUGS/FITTINGS MISSING FROM OIL CONTAINMENT BOXES.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Accommodation/Occupational Safety
Issued 21 June 1995
Resolved
HANDRAIL MISSING ON PORT/STBD LIFERAFT/LIFEBOAT DECK.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 21 June 1995
Resolved
WEAK LINKS MISSING FROM LIFERAFTS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 13 July 1994
Resolved
VESSELS 3 LIFERAFTS WERE NOT ANNUALLY INSPECTED
Condition: Unknown
Due 21 June 1995
Resolved 21 June 1995
Navigation
Issued 15 October 1986
Resolved
VESSEL WAS OPERATED WITHOUT CHARTS REQUIRED BY 33CFR164.33(A)(1)
Condition: Unknown
Due 21 June 1995
Resolved 21 June 1995