ELENE is a 1982 freight ship. The Coast Guard has recorded 27 inspections since 1984, most recently in August 2008, along with 17 deficiencies and 3 operational controls, 1 with no removal date recorded.

Records from 1984 to 2008. Most recent: inspection, 27 August 2008.

Built
1982
Last inspected
27 August 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

8106379 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227166
Flag
MALTA
—
Maury page id
psix-227166

Inspections, by type

…with no type recorded21
Years with a record 18 calendar years (1984–2008)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it14928 - Convention (Subpart B), Net Ton
24593 - Convention (Subpart B), Gross Ton
43385 - Dead Weight, Ton
53318 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 27

27 August 2008 ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3303152
9 February 2007 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2869838
25 September 2006 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2786499
14 July 2005 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2426630
6 July 2005 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2418314
4 May 2005 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2349100
28 October 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2230311
28 September 2004 ISPS II Exam · Annual Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2209372
28 September 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2230178
22 October 2003 Annual Inspection · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1933461
9 May 2000 Examination of Repairs
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1463590
5 February 2000 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 274340
31 December 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424005
26 November 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 410503
20 November 1996 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 397174
4 February 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 518758
2 February 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 351471
31 January 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 341658
22 October 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 511109
26 March 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 329124
16 April 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 322338
27 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 455620
20 January 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 320822
27 October 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 312377
1 February 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 460373
16 August 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 303705
7 August 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 297505

Deficiency record · 17

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 September 2004 Resolved
Monitor had non-factory wiring. Prove proper installation and operation of 15 ppm monitor.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2004
Resolution: OEM installed new OWS with new 15 ppm monitor
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 September 2004 Resolved
Correct wasted piping connecting primary and secondary separating tanks on OWS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 September 2004
Resolution: Replace wasted piping.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 September 2004 Resolved
After repairs, prove operation of OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2004
Resolution: Installed new OWS and tested it satisfactory.
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 28 September 2004 Resolved
Correct poor condition of firefighter ensamble self contained breathing apparatus. Must replace mask and oxygen hose due to dry rot and holes. Also, vessel needs to refill one oxygen bottle.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2004
Resolution: Vessel purchased two new SCBAs with six new oxygen bottles.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 28 September 2004 Resolved
Provide hot water and repair sinks, faucets, toilets and overhead piping leaks.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 30 September 2004
Resolution: Adjusted steam valve to lower the hot water temperature. Tightened faucets, patched piping and plumbing.
Construction/Loadline › Structures › Trunk
Issued 28 September 2004 Resolved
Repair or replace original support stantions for ships store cranes on stern near stack to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 4 October 2004
Resolution: The two stantions that were holed at the base were doubled up to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 28 September 2004 Resolved
Must have Original Equipment Manufacturer representative attest to the satisfactory operation of the OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 October 2004
Resolution: OEM was present during installation of new OWS. After installation, Marine Inspector conducted satisfactory operational test of OWS.
Engineering › Freshwater System (piston cooling)
Issued 22 October 2003 Resolved
S/W PIPE FOR PISTON COOLER WASTED AND LEAKING, REPAIR TO THE SATISFACTION OF CLASS SOCIETY LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 25 October 2003
Resolution: Received Class report attesting to the repair.
Engineering › Sea-water System (primary cooling)
Issued 22 October 2003 Resolved
S/W PIPE FOR CONDENSOR PATCHED AND WASTED, AND ISOLATION VALVE FOR SYSTEM IS LEAKING THROUGH THE VALVE BODY, REPAIR TO THE SATISFACTION OF CLASS LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 25 October 2003
Resolution: Received class report attesting to the repair.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 22 October 2003 Resolved
CLASS SOCIETY TO ATTEST TO PROPER REPAIR OF HYDRAULIC HATCH REMOVAL SYSTEM. OBSERVED COARGO HATCH NO. 3 AFT COVER SECTION BEING REMOVED BY CRANE INSTEAD OF HYDRAULIC SYTEM. ALSO HOLD NO. 5 IS SAME LEGACY COMPONENT DESC: Hatch
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 November 2003
Resolved 1 October 2004
Resolution: Received class report dated 11/18/2003. Hydraulic valve of hatch cover #3 has been overhauled. Pulling chain of hatch cover #5 has been renewed and adjusted. Both verified by class as satisfactory.
Construction/Loadline › Hull
Issued 22 October 2003 Resolved
CLASS SOCIETY SURVEYOR TO ATTEST TO THE STRUCTURAL INTEGRITY OF SIDESHELL PLATING PORT SIDE AFT OF BOLBOUS BOW, HEAVY PITTING OBSERVED LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 23 November 2003
Resolved 25 October 2003
Resolution: Received class report attesting to the repair.
Lifesaving › Launching Appliances
Issued 22 October 2003 Resolved
DURING LIFEBOAT DRILL, PNEUMATIC WINCH MALFUNCTIONED AND LIFEBOAT WAS NOT ABLE TO BE RAISED. CLASS TO ATTEST TO THE PROPER OPERATION OF LIFEBOAT INLUDING PNUEMATIC WINCH PRIOR TO DEPARTURE LEGACY COMPONENT DESC: Winch
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2003
Resolved 25 October 2003
Resolution: Received class report attesting to the repair.
Fire Fighting › Firemans Outfit
Issued 22 October 2003 Resolved
GLOVES FOR BOTH FIREMANS OUTFITS ARE TORN/WASTED. REPLACE WITH NEW SET OF FIREMANS GLOVES PRIOR TO DEPARTURE FROM PORT LEGACY COMPONENT DESC: Gloves
Action required: 17 - Rectify deficiencies prior to departure
Due 23 October 2003
Resolved 25 October 2003
Resolution: Received class report attesting to the replacement of gloves.
Construction/Loadline
Issued 9 May 2000 Resolved
PROVIDE LOCAL OCMI WITH A REPORT FROM CLASS (ABS) CONCERNING EXTENT OF THE WASTAGE LOCATED IN THE FRAMES OF CARGO HOLDS.
Condition: Unknown
Due 15 May 2000
Resolved 30 May 2000
Documentation
Issued 2 February 1992 Resolved
APHIS OFFICER OBSERVED THAT THE VESSEL CONSOLIDATES ALL GARBAGE INCLUDING PLASTIC INTO OCEAN DISPOSAL WASTE AND REPORTED THAT THE VESSEL DISCHARGES THIS WASTE AT SEA. THIS OBSERVATION WAS NOT VERIFIED BY CG BOARDING.
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Navigation
Issued 31 January 1991 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT HAVING CHARTS 12334, AND 12333 ON BOARD AS REQUIRED BY 33 CFR 164.33(A)(1)
Condition: Unknown
Due 8 February 1994
Resolved 8 February 1994
Navigation
Issued 20 January 1988 Resolved
33CFR164.30 VESSEL WAS OPERATED INTO THE PORT OF CORPUS CHRISTI,TX WITHOUT AN ARPA, WHICH IS REQUIRED BY 33CFR164.38(B),AND WITHOUT A SOLAS EXEMPTION CERTIFICATE. PANAMANIAN CONSULATE REQUESTED PERMISSION TO COMPLETE VOYAGE, VESSEL TO PROCEED TO JAPAN FOR INSTALLATION OF ARPA.
Condition: Unknown
Due 20 January 1988
Resolved 20 January 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.