← All vessels
JOVIALITY
JOVIALITY is a 1982 freight ship. The Coast Guard has recorded 26 inspections since 1988, most recently in April 2009, along with 30 deficiencies — 1 with no resolution recorded — and 7 operational controls.
Records from 1988 to 2009. Most recent: inspection, 5 April 2009.
- Built
- 1982
- Last inspected
- 5 April 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 30 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8106434 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRWF7
227167
Flag
LIBERIA
—
Maury page id
psix-227167
Inspections, by type
…with no type recorded21
…past their stated due date1
Years with a record
14 calendar years (1988–2009)
The 26 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it13808 - Convention (Subpart B), Net Ton
45564 - Dead Weight, Ton
55305 - Displacement, Ton
13808 - Regulatory (Subpart C or D), Net Ton
28224 - Convention (Subpart B), Gross Ton
28224 - Regulatory (Subpart C or D), Gross Ton
45564 - Dead Weight, Ton
55305 - Displacement, Ton
13808 - Regulatory (Subpart C or D), Net Ton
28224 - Convention (Subpart B), Gross Ton
28224 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 26
5 April 2009
ISPS I Exam
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3442903
4 April 2009
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3443107
16 October 2007
Random ISPS/MTSA/PSC
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3080476
11 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2885583
11 March 2007
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2885724
2 February 2006
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2578075
27 January 2006
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2574797
14 November 2005
ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2534561
7 October 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2216030
15 September 2004
NPV Safety Exam · ISPS II Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2196166
13 June 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2097309
4 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 282649
2 June 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 429269
2 June 1999
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 429441
23 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 110438
10 February 1998
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 413774
27 March 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 389447
22 August 1994
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 369650
9 June 1993
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 512113
18 August 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 352597
12 August 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 645780
29 July 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 104798
29 July 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 352277
25 July 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 459630
13 November 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 333661
1 June 1988
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 323616
Deficiency record · 30
Deck/Cargo › Mooring/Anchoring › Winch
Issued 30 March 2009
No resolution recorded
VESSEL WAS UNABLE TO RAISE THEIR PORT SIDE ANCHOR DUE TO A MALFUNCTION WITH THE PORT SIDE WINLASS.
Construction/Loadline › Markings › Load Line Mark
Issued 16 October 2007
Resolved
Load Line markings were not in contrasting color to the hull. Code 70AB
Construction/Loadline › Hull › Transverse Frame
Issued 16 October 2007
Resolved
In hold #5 broken frame found near frame #55. Captain was told no cargo may be loaded in hold 5 until Class inspects to their satisfaction. ICLL ANNEX 14 (Code 17A)
Construction/Loadline › Hull › Bracket
Issued 16 October 2007
Resolved
Patches found on Hold 3 forward ballast vent. Found broken braces for both ballast vent pipes in hold 5. Rectify to the satisfaction of class. (Code 17A)
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 October 2007
Resolved
Found wasted guardrails with 3 broken stanchions on stairwell leading down into hold 5. (Code 17A)
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 October 2007
Resolved
Found cracks on most hatch covers near center line of vessel. Hatch covers stops are also missing bolts. (Code 17A)
Documentation › Manuals/Policy Documentation › Cargo/Ballast System Instruction Manual
Issued 16 October 2007
Resolved
BWM Plan is missing list of all ballast tanks/holds and their capacities. (Code 70AB)
Operations/Management › Pollution › Control of Garbage
Issued 16 October 2007
Resolved
Garbage management plan does not list all types of receptacles or storage area for garbage. Green cans found throughout accommodation and a black and orange can found in E/R for batteries, but not listed in plan. Plan does not specify what to do with light bulbs. Plan does not specify what can be burned in the incinerator. Metal waste was found in the incinerator ash. (Code 17A)
Electrical › Lighting (service) › Lighting Fixture
Issued 16 October 2007
Resolved
Crew installed secondary lighting system by splicing in the forward boatswains store and in the engine room weld shop. (Code 17A)
Fire Fighting › Structural - A Class Divisions › Doors
Issued 16 October 2007
Resolved
The following (but not limited too) self-closing doors were found inoperable: Both A/C rooms, Galley, laundry room, engine room entry, and exterior upp deck doors. Storage 'A' space on bridge is missing a door. Class must check/determine if all doors meet ship's fire plan. (Code 17A)
Construction/Loadline › Structures › Door
Issued 16 October 2007
Resolved
Hospital exterior door is not weather tight. Class must check all exterior doors for weather tightness. ICLL Article 14 (Code 17A)
Lifesaving › Lifeboat › Canopy
Issued 16 October 2007
Resolved
The port lifeboat is missing the canopy. The starboard lifeboat canopy is not marked with ship identification.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 16 October 2007
Resolved
Length of starboard rescue boat embarkation ladder is not adequate. Class must inspect both ladders. (Code 17A)
Fire Fighting › Fire Hoses › Condition
Issued 16 October 2007
Resolved
Each fire hose station requires at least the hose and nozzle. Crew removed all nozzles on deck forward of superstructure in fear of theft. Nozzles were locked in ship's main fire station on upp deck. Two 65mm hoses at boxes 11 & 19 had damaged rubber lining. Records indicate all hoses in good condition. Fire extinguishers # 18 & 19 in ECR and #38 in steering gear flat had cracked rubber hoses.17A
Fire Fighting › Ventilation Systems › Exhaust Ducts (Galley Ranges)
Issued 16 October 2007
Resolved
Ventilation duct above galley range is leaking grease from the seams and patched. Ventilation duct in ship's main fire station is wasted. (Code 17A)
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 16 October 2007
Resolved
Engine room supply hatch was not bolted down. Activation of fixed CO2 fire suppression system may not have worked properly. (Code 17A)
Electrical › Electrical Distribution System (service) › Junction Box
Issued 16 October 2007
Resolved
Electrical junction box covers on both provisions cranes are missing, and have been replaced with plastic cups and tape. The limit switches on both cranes have wasted and appear inoperable. ILO 152 (Code 17A)
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 16 October 2007
Resolved
Marine Sanitation Device is not being used IAW manufactures instructions. No test kit on board. Chemicals used in system don't appear to be the required type. The tablet chamber is wasted. There is a pinhole leak on the overboard discharge line. Two patches found in sewage pipes above MSD. (Code 17A)
Engineering › Feedwater/Condensate Water System › Piping
Issued 16 October 2007
Resolved
Patches found in the following locations: steam condensate line with two leaks, and the ballast water line to eductor pump. Master and company were unaware of patches. (Code17A)
Deck/Cargo › Mooring/Anchoring › Winch
Issued 16 October 2007
Resolved
Crew added vent from forward mooring winches up through deck. Class must check the arrangement. (Code 17A)
Documentation › Logs/Records › Oil Record Book
Issued 16 October 2007
Resolved
Use of the incinerator was logged in the oil record book and a second separate garbage record book. The incinerator entries for sludge in the second garbage record book were not in the oil record book. Garbage has also been burned in the incinerator and not logged. The plan does not detail use of incinerator for garbage. (Code 17A)
Engineering › Sea-water System (primary cooling) › Piping
Issued 11 March 2007
Resolved
The vessel's seawater intake lines had a soft patch on the elbow. The vessel is to make permanent repairs to the piping to the satisfaction of class.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 11 March 2007
Resolved
The insulating bricks in the incinerator are wasted/worn to the extent that the paint is melting off the exterior of the incinerator, creating a hazardous condition. The insulating bricks are to be replaced or repaired to the satisfaction of class.
Navigation
Issued 4 October 2000
Resolved
PROVIDE TECHNECIAN'S REPORT ATTESTING TO THE PROPER OPERATION AND CALIBRATION OF THE GYRO AND MAGNETIC COMPASSES.
Navigation
Issued 22 August 1994
Resolved
PROVIDE A CURRENT AND CORRECTED UP TO DATE U.S. COAST PILOT.
Navigation
Issued 22 August 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF VESSEL'S (ARPA) AUTOMATIC RADAR PLOTTING AID.
Engineering
Issued 22 August 1994
Resolved
WIRING ON THE 15PPM OILY WATER SEPARATOR'S OIL CONTENT ALARM WAS NOT PERMANENT.
Documentation
Issued 18 August 1992
Resolved
GARBAGE NOT SEGREGATED IN PREPARATION FOR PROPER DISPOSAL. EMPHASIS ON PLASTICS.
Documentation
Issued 18 August 1992
Resolved
WASTE MANAGEMENT PLAN NOT ON BOARD
Navigation
Issued 1 June 1988
Resolved
SATNAV. WAS NOT WORKING AND WAS IN THE PROCESS OF BEING REPLACED.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.