MAURY USCG vessel records Sign in
← All vessels

BRIGHT ZHEJIANG

BRIGHT ZHEJIANG is a 1983 freight ship. The Coast Guard has recorded 20 inspections since 1986, most recently in August 2000, along with 21 deficiencies — 4 with no resolution recorded — and 3 operational controls.

Records from 1986 to 2000. Most recent: inspection, 16 August 2000.

Built
1983
Last inspected
16 August 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8111582 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227208
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-227208

Inspections, by type

…with no type recorded20
…past their stated due date4
Years with a record 11 calendar years (1986–2000)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it21944 - Regulatory (Subpart C or D), Net Ton
37811 - Regulatory (Subpart C or D), Gross Ton
67944 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

16 August 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 638868
15 August 2000 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 280955
13 August 2000 Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 1496998
10 December 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 410653
12 November 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 409971
27 July 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 654665
13 July 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 405740
12 January 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 398966
11 March 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 388819
3 December 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 372571
3 December 1994 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 870974
7 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 357499
2 September 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 504688
22 March 1992 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 349598
7 May 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 337006
21 June 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331040
4 April 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 329799
15 May 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 323320
13 February 1987 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 314263
19 September 1986 Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 500843

Deficiency record · 21

Electrical
Issued 15 August 2000 No resolution recorded
PROVIDE COVER OR CASING FOR OILY WATER SEPARATOR THREE-WAY VALVE WIRES._x001C_ SOLAS 74 (UNAMENDED) II-1/27
Condition: Unknown
Due 15 September 2000 — due date passed with no resolution recorded
Engineering
Issued 15 August 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL LEAKING STEAM PIPE LOCATED IN ENGINE ROOM, LOWER LEVEL, PORT SIDE, FORWARD OF MAIN ENGINE BELOW DECK PLATE._x001C_ SOLAS 74 (UNAMENDED) I/11_x001C_
Condition: Unknown
Due 15 September 2000 — due date passed with no resolution recorded
Navigation
Issued 15 August 2000 Resolved
PROVIDE UP-TO-DATE CHARTS OF MOBILE BAY AND APPROACHS PRIOR TO DEPARTURE._x001C_ 33 CFR 164.33
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Documentation
Issued 15 August 2000 Resolved
PROVIDE VALID SAFE MANNING CERTIFICATE APPROVED BY ADMINISTRATION PRIOR TO DEPARTURE._x001C_ SOLAS 74 (AMENDED) V/13(B)
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Engineering
Issued 15 August 2000 No resolution recorded
REPAIR/RENEW AS ORIGINAL LEAK IN AFT END OF MAIN ENGINE LUBE OIL COOLING CYLINDER._x001C_ SOLAS 74 (unamended) I/11
Condition: Unknown
Due 15 September 2000 — due date passed with no resolution recorded
Electrical
Issued 15 August 2000 No resolution recorded
REMOVE ELECTRICAL POWER CABLE FOR FRESH WATER GENERATOR PUMP WHICH IS ATTACHED TO HANDRAIL. REPLACE WITH PROPERLY LOCATED OVERHEAD CABLE._x001C_ SOLAS 74 (UNAMENDED) II-1/27_x001C_ _x001C_
Condition: Unknown
Due 15 September 2000 — due date passed with no resolution recorded
Navigation
Issued 15 August 2000 Resolved
PROVE PROPER OPERATION OF ECHO DEPTH SOUNDER, PRIOR TO DEPARTURE._x001C_ 33 CFR 164.53
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Navigation
Issued 12 November 1997 Resolved
VESSELS ARPA RADAR INOPERATIVE._x001C_ _x001C_ 33 CFR 164.38(b)3(ii)
Condition: Unknown
Due 12 November 1997
Resolved 5 December 1997
Navigation
Issued 12 November 1997 Resolved
VESSELS SECONDARY RADAR INOP_x001C_ _x001C_ 33 CFR 164.37(a)
Condition: Unknown
Due 12 November 1997
Resolved 5 December 1997
Lifesaving
Issued 12 November 1997 Resolved
UNABLE TO COMPLETE SATISFACTORY FIRE DRILL_x001C_ _x001C_ SOLAS 74 AMENDED III/18.3.10
Condition: Unknown
Due 12 November 1997
Resolved 5 December 1997
Engineering
Issued 12 November 1997 Resolved
VESSEL'S CONTROL AIR REDUCTION UNIT INOPERATIVE._x001C_ _x001C_ SOLAS 74 AMENDED I/11
Condition: Unknown
Due 12 November 1997
Resolved 5 December 1997
Navigation
Issued 13 July 1997 Resolved
INLAND NAV RULES NOT ONBOARD
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Lifesaving
Issued 13 July 1997 Resolved
STARBOARD FOREWARD DAVIT ARM WASTED IN THE WAY OF THE FALL GUY/FALL STOP.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Electrical
Issued 13 July 1997 Resolved
EMERGENCY GENERATOR FUEL LINE WASTED. PRESSURE FUEL LINE LEAKING ON ENGINEMANIFOLD. SOLAS 74(AMENDED)REG' II-1/43. VESSEL REQUIRED TO SUPPLY CLASS REPORT BEFORE DEPARTING US PORT.
Condition: Unknown
Due 18 July 1997
Resolved 16 July 1997
Lifesaving
Issued 13 July 1997 Resolved
CREW WERE NOT FAMILIAR WITH THERE DUTIES DURING TWO FIRE DRILLS. SOLAS 74 REG.18-3/3.1. CORRECT PRIER TO DEPARTURE FROM US PORT.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Navigation
Issued 13 July 1997 Resolved
VESSEL WAS MISSING THE UPDATES FOR CHART 18751.
Condition: Unknown
Due 16 July 1997
Resolved 16 July 1997
Navigation
Issued 12 January 1997 Resolved
Steering gear in emergency arrangement was sluggish to respond upon initialtest. Crew removed copious amounts of grease and used solvent to clean mechanisms. Test completed satisfactorily.
Condition: Unknown
Due 13 January 1997
Resolved 13 January 1997
Electrical
Issued 11 March 1996 Resolved
EMERGENCY GENERATOR NOT TESTED DUE TO BUNKERING OPERATIONS.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Lifesaving
Issued 11 March 1996 Resolved
EMERGENCY DRILLS NOT CONDUCTED DUE TO NIGHTTIME BUNKERING OPERATIONS IN PROGRESS.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997
Engineering
Issued 7 May 1990 Resolved
INSTALL OR REPLACE FLAME SCREENS IN ALL FUEL OIL/LUBE OIL DECK TANK VENTS._x001C_
Condition: Unknown
Due 3 September 1992
Resolved 2 September 1992
Navigation
Issued 4 April 1989 Resolved
VESSEL FAILED TO HAVE AFFIXED ARPA LABLE.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.