Records from 1984 to 2007. Most recent: operational control imposed, 24 May 2007.
Inspection history · 32
21 May 2007
MARPOL Annex I Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2936473
8 May 2007
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2925452
26 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2862295
17 January 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2857143
12 January 2007
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2854933
23 September 2004
Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2199523
29 June 2004
Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2114931
26 February 2004
Re-Inspection · Deficiency Check · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2013956
26 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2015401
24 March 2003
Annual Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1761849
5 March 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1491964
26 February 2002
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1489636
30 March 2001
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 288467
12 July 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 430400
17 December 1997
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 410923
26 July 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393623
8 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 371147
7 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172055
7 October 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172686
25 August 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 681307
23 August 1993
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 360361
3 December 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 354927
5 February 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 681301
30 January 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 348618
8 August 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 533315
9 November 1990
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 340164
14 December 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 524034
10 October 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 332997
6 August 1987
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 440918
16 December 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 313287
10 June 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 302495
18 December 1984
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 458316
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 21 May 2007
Resolved
The OWS had blank flanges on the 3-way valve. MARPOL exam was expanded. Piping assembly was found that bypasses the OWS and discharges directly overboard. Vessel was detained and required to make piping IAW approved plans and to class satisfaction. MISLE cites for MARPOL 73/78 are not up-to-date. MARPOL Annex I/reg 6.4.1 & 4.2 are the correct cites. Refer to the scanned CG-5437B form.
Action required: 705 - Other - as specified
Resolved 29 May 2007
Resolution: Vessel installed correct piping system for the OWS to the satisfaction of class and the CG. Detention lifted.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 12 January 2007
Resolved
Echo-Sounding Device Recorder inoperable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 January 2007
Resolution: Received Class Report attesting to repairs made by certified technician.
Fire Fighting › Fire Hoses › Connections
Issued 12 January 2007
Resolved
Fire hose in Engine room leaks at hose to fitting coupling.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 January 2007
Resolved 16 January 2007
Resolution: Fire hoses replaced.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 January 2007
Resolved
Light fixture above medicine cabinet in cabin 27 is missing with exposed wires.
Condition: Improper/Lack of Maintenance
Due 12 February 2007
Resolved 16 January 2007
Resolution: Light fixture wiring now is a safe manner.
Construction/Loadline › Structures › Door
Issued 12 January 2007
Resolved
Door leading from galley to weather deck is out of adjustment and does not close properly.
Condition: Improper/Lack of Maintenance
Due 12 February 2007
Resolved 16 January 2007
Resolution: Combing on door renewed and weathertight integrity restored.
Construction/Loadline › Structures › Scupper
Issued 12 January 2007
Resolved
Condition: Placed in Improper Service
Due 12 February 2007
Resolved 16 January 2007
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 12 January 2007
Resolved
Refer escape devices were loose to the point where they did not contact the handles.
Condition: Improper/Lack of Maintenance
Due 12 February 2007
Resolved 16 January 2007
Resolution: Refer escape devices renewed.
Navigation › Collision/Grounding Avoidance
Issued 26 February 2004
Resolved
The vessel's secondary radar is inoperative. Provide technician's report for repairs to the satisfaction of the U.S. Coast Guard. LEGACY COMPONENT DESC: Radar
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 1 March 2004
Resolution: Received radar tech report satisfying requirement.
Lifesaving › Lifebuoys
Issued 24 March 2003
Resolved
PROVIDE WATERLIGHT BRACKETS THAT PROPERLY FIT EXISTING WATERLIGHTS ON BOTH PORT AND STBD SIDE OF BOAT DECK. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 26 February 2004
Resolution: Witnessed satisfactory repairs during PSC Boarding.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2003
Resolved
PROVIDE PROPER CONTAINMENT FOR DISCHARGE SLUDGE TRANSFER POINT ON PORT AND STBD SIDE, MAIN DECK. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 26 February 2004
Resolution: Witnessed satisfactory repairs during PSC Boarding.
Pollution Prevention/Response › Prevention Equipment
Issued 24 March 2003
Resolved
PROVIDE PROPER CONTAINMENT FOR CYL. OIL AND M.E. GEN. OIL VENTS AND TRANSFER POINTS ON PORT AND STBD SIDE, MAIN DECK. LEGACY COMPONENT DESC: Fixed Containment
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 April 2003
Resolved 26 February 2004
Resolution: Witnessed satisfactory repairs during PSC Boarding.
Lifesaving › Inflatable Liferafts
Issued 24 March 2003
Resolved
PROVIDE 04 HYDROSTATIC RELEASES FOR LIFERAFTS THAT MEET THE REQUIREMENTS OF
SOLAS 74 AMD CH 3 LSA CODE REG 4.1.6.3. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 25 March 2003
Resolved 24 March 2003
Resolution: RECEIVED RECEIPT OF PURCHASE OF PROPER HYDROSTATIC RELEASES.
Engineering
Issued 12 July 1999
Resolved
VESSEL'S BUNKER LINE IS NOT PRESSURE TESTED OR RECORDED AS REQUIRED BY 33 CFR 156.170(a)(4). CORRECT PRIOR TO NEXT U.S. BUNKERING.
Condition: Unknown
Due 19 July 1999
Resolved 20 July 1999
Lifesaving
Issued 12 July 1999
Resolved
PORT LIFEBOAT SEATING POSITIONS NOT MARKED AS REQUIRED BY SOLAS 74 CHAPTER III REG 41/2.3. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 1 August 1999
Resolved 20 July 1999
Lifesaving
Issued 17 December 1997
Resolved
PROVIDE SOLAS APPROVED 6 MAN LIFERAFT AS PER SOLAS CH III REG 35(C).
Condition: Unknown
Due 18 December 1997
Resolved 19 December 1997
Engineering
Issued 26 July 1996
Resolved
Oil containment for the F.O. vents on deck have wood plugs, vice mechanicalfittings and plugs as required in MARPOL 73/78 annex 1/9 and CFR 155.310.
Condition: Unknown
Due 19 December 1997
Resolved 19 December 1997
Navigation
Issued 23 August 1993
Resolved
33 CFR 164.11(r) The ARPA required by 33 CFR 164.38(b)(3)(ii) was not maintained in operable condition.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Accommodation/Occupational Safety
Issued 23 August 1993
Resolved
33 CFR 151.57 The vessel did not have a waste management plan. Vessel's master agreed to create plan._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Navigation
Issued 23 August 1993
Resolved
33 CFR 164.53(b) The person directing the movement of the vessel failed toreport or cause to report to the USCG that the vessel's ARPA was not operating properly. During the boarding, the USCG boarding officers found that the equipment was not operating properly .
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Documentation
Issued 23 August 1993
Resolved
33 CFR 155.820(b) The vessel did not have record of the hydrostatic test for the transfer pipe system that is required to be conducted by 33 CFR 156.170(c)(4). Vessel to conduct test and provide proof to USCG that it_x001C_ was conducted prior to receiving bunkers in the United States._x001C_
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Documentation
Issued 30 January 1992
Resolved
WHILE CONDUCTING AN ANNUAL EXAM THE BOARDING OFFICERS NOTED THAT THE VESSELDID NOT HAVE OIL TRANSFER PROCEDURES._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 February 1992
Resolved 4 February 1992
Navigation
Issued 10 October 1989
Resolved
VESSEL FAILED TO NOTIFY THE COTP OF INOPERABLE ECHO DEPTH SOUNDING DEVICE AS REQUIRED BY 33 CFR 164.53(B).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989
Resolved
VESSEL TRANSITED PUGET SOUND WITH ECHO DEPTH SOUNDER CONTINOUS RECORDER INOPERABLE AS REQUIRED BY 33 CFR 164.35(I).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989
Resolved
VESSEL TRANSITED PUGET SOUND WATERS UTILIZING CHARTS NOT CURRENLTY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(1)(II) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IN ACCORDANCE WITH 33 CFR 164.33(B).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH U.S. COAST PILOT 7 NOT CURRENTLY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(2)(I) OR EQUIVALENT FOREIGN GOVERNMENT CHARTS IN ACCORDANCE WITH 33 CFR 164.33(B).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 October 1989
Resolved
VESSEL TRANSITED PUGET SOUND WATERS WITH COAST GUARD LIGHT LIST NOT CURRENLTY CORRECTED WITH CHANGES CONTAINED IN NOTICE TO MARINERS AS REQUIRED BY 33 CFR 164.33(A)(2)(II) OR AN EQUIVALENT GOVERNMENT PUBLICATION IN ACCORDANCE WITH 33 CFR 164.33(B).
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Documentation
Issued 10 October 1989
Resolved
VESSEL'S OIL TRANSFER PROCEDURES WERE NOT IN ACCORDANCE WITH 33 CFR 155.750.
Condition: Unknown
Due 10 October 1989
Resolved 10 October 1989
Navigation
Issued 10 June 1985
Resolved
VESSEL COAST PILOT VOL.7 (1984 ED) WAS NOT CURRENTLY CORRECTED.
Condition: Unknown
Due 10 June 1985
Resolved 10 June 1985