Records from 1984 to 2008. Most recent: inspection, 28 August 2008.
Inspection history · 56
28 August 2008
MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3310495
15 July 2008
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3268770
14 July 2008
Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3268708
28 March 2008
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3173089
14 February 2008
ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · MARPOL Annex V Examination · Deficiency Check · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3147338
11 February 2008
MARPOL Annex I Examination · MARPOL Annex V Examination · Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3143643
10 February 2007
MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2868606
12 October 2006
Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2799516
23 January 2006
Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex V Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2571334
11 December 2005
ISPS I Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2549601
28 April 2005
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2344701
11 April 2005
MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS III Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2328602
21 January 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2278726
21 January 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2278875
28 September 2004
PII Safety Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2206959
16 July 2004
ISPS II Exam
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2130049
9 March 2004
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2021491
23 September 2003
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1911066
18 September 2003
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1907567
24 April 2003
Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1776104
11 March 2003
Annual Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1754794
29 September 2002
Re-Inspection · Ballast Water Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1682024
23 February 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1488746
28 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 294176
9 March 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 287663
25 October 2000
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 283263
24 February 2000
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 275022
8 March 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 426328
8 February 1999
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 425214
27 May 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 404110
24 April 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 403047
11 March 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401466
21 March 1996
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 539926
15 March 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 388895
1 February 1995
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 374568
6 January 1995
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 373934
15 November 1994
Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 538874
15 November 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1412712
23 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 367897
23 June 1994
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 496337
1 December 1993
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 362811
18 June 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 507176
1 November 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 353998
4 October 1992
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 354152
11 October 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 444056
24 April 1991
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 540185
9 July 1990
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 338580
27 June 1989
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331193
29 June 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 324198
6 January 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 484263
17 May 1987
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 316115
10 March 1987
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 484050
10 October 1986
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 495586
30 January 1986
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 306661
11 May 1985
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 450117
10 December 1984
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 299481
Navigation › Piloting/Steering › Gyro Compass
Issued 14 July 2008
Resolved
Vessel requested LOD for inoperable gyrocompass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2008
Resolution: Necessary repairs made, vsl cleared to sail.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 February 2008
Resolved
Gas-Tight, class "A" fire door from Cargo Deck 13 to accommodation space lobby/vestibule does not latch: gasket on latch side gapped at top and bottom of door.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 14 February 2008
Resolution: Received NKK Class Report. Deficiency cleared.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 11 February 2008
Resolved
Insulation blanket on exhaust gas economizer in upper engine room extensively wasted along bottom surface near vertical piping, indicating potential wastage of internal structure of economizer. SOLAS 74/78 I/11
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 14 February 2008
Resolution: Received NKK Class Report. Deficiency cleared.
Engineering › Steering Gear System › Piping
Issued 11 February 2008
Resolved
Rudder post automatic lubrication system sight-glasses on rudder pedestal cracked and temporarily repaired with tape. Sight glasses positioned in high-vibration area and thereby subject to fracture. Lubrication pressure to rudder post potentially decreased. Class to provide report attesting to satisfactory repair or advisability of removing sight glasses. SOLAS 74/78 II-1/29(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 14 February 2008
Resolution: Received NKK Class Report. Deficiency cleared.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 11 February 2008
Resolved
Flexible hose rigged from drain settling tank in fuel oil purifier room to drain pipe arrangement from fuel oil purifier. Second engineer reports hose used to drain waste oil from tank directly to sludge tank. Class NK to provide report attesting to necessity of procedure and possible implementation of permanent arrangement. SOLAS 74/78 II-2/33(a)(viii) & 51(g)
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 14 February 2008
Resolution: Received NKK Class Report. Deficiency cleared.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 11 February 2008
Resolved
Non-conformities and their possible causes not reported to Company: damage to rudder post lubrication system not reported; wastage of exhaust gas economizer not reported. Class NK to provide report attesting to proper implementation of reporting procedures for materiel non-conformities. SOLAS 74 (Amend) IX/3.1 $ ISM A/5.1.4 & 10.2.2
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2008
Resolved 18 March 2008
Resolution: Received Class NK report, see attached for further information.
Engineering › Steam Boiler (auxiliary/waste heat) › Outer Casing
Issued 23 January 2006
Resolved
Aux boiler in engine room, starboard side, steam coming off the boiler causes the fire alarm to activate. Steam escaping from cover on boiler.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 February 2006
Resolved 28 February 2006
Resolution: recieved class report.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 11 April 2005
Resolved
Two 55 gallon drums of flammable liquid found within 5 feet of main diesel engine, approximately 3/4 full with no lid.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 April 2005
Resolved 13 April 2005
Resolution: JACMS verified drums covered and moved away from main diesel engine.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 11 April 2005
Resolved
Fire screen doors leading from purifier room found tied open, with rubber hose protruding through.
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 11 April 2005
Resolved 13 April 2005
Resolution: JACMS verified doors no longer tied open; capable of closing without interference.
Construction/Loadline › Structures › Door
Issued 11 April 2005
Resolved
Starboard sideshell cargo door/ramp questionable: Standing water found ondeck at base of door. When opened, door does not raise sufficiently to engage locking pins to prevent catastrophic release.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 13 April 2005
Resolution: Received Class Survey report from NKK stating door watertight and requiring repair of handrails above door, which were damaged while trying to hold door open with cargo straps.
Engineering
Issued 18 September 2003
Resolved
BOWTHRUSTER INOPERABLE MASTER HAD NOT NOTIFIED CLASS.
ISSUED DEFICIENCY TO HAVE CLASS MAKE RECOMMENDATION.
LEGACY COMPONENT DESC: BOWTHRUSTER
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2003
Resolved 18 September 2003
Resolution: A CONDITION OF CLASS HAS BEEN ISSUED.
VESSEL MUST REPAIR BOW-THRUSTER AT NEXT DRY DOCK OR NO LATER THEN 24JAN 2005
Lifesaving › Inflatable Liferafts
Issued 11 March 2003
Resolved
Approve arrangement where the inflatable life raft painters and actuator lines are extended from cannister and stowed in a bag rigged under bracket. SOLAS 74 I/11. LEGACY COMPONENT DESC: Painter
Action required: 15 - Rectify deficiencies by next port
Resolved 14 March 2003
Resolution: Received copy of class report approving arrangement of inflatable life raft painters and actuator lines.
Lifesaving › Launching Appliances
Issued 11 March 2003
Resolved
Perform maintenance on the port lifeboat falls where on the first attempt to lower away davit was stuck, and limit switch adjustment required for both port and stbd davits. SOLAS 74 I/11. LEGACY COMPONENT DESC: Davit
Action required: 15 - Rectify deficiencies by next port
Resolved 14 March 2003
Resolution: Received copy of class report indicating that the required maintenance and adjustments were made to the satisfaction of class.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 11 March 2003
Resolved
Develop and implement plan for CO2 to engine room actuator box padlock key. SOLAS 74 I/11. LEGACY COMPONENT DESC: Operating Controls
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2003
Resolution: Key is in Master''s stateroom.
Fire Fighting › Fixed Fire Detection System
Issued 11 March 2003
Resolved
Prove proper operation of heat detectors in steering gear room and engine room. Detectors have been tested using open flame and have melted portions of detectors. SOLAS 74 I/11 LEGACY COMPONENT DESC: Heat Detectors
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2003
Resolution: Tested heat detectors in both engine room and steering gear room using smoke.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 March 2003
Resolved
Guard around hand cranked starting chain has been removed. Replace guard as originally provided. (Emergency fire pump) ILO 147 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2003
Resolution: Visually inspected new guard.
Fire Fighting › Combustible Materials
Issued 11 March 2003
Resolved
Remove excess combustible and flammable liquids stored in engine room behind generators. 46 CFR 147.45
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2003
Resolution: No excess liquids found stored in engine room behind generators.
Accommodation/Occupational Safety › Occupational Safety
Issued 11 March 2003
Resolved
Replace lagging on emergency fire pump exhaust manifold. Lagging was removed due to smoking after running pump for approx. 10 minutes. ILO 147 LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 24 April 2003
Resolution: All lagging on emergency fire pump has been replaced.
Navigation
Issued 8 February 1999
Resolved
Repair telephone in steering room where bell doesn't work. SOLAS 74 I/11. Complete prior to next U.S. Port after sailing foreign.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Engineering
Issued 8 February 1999
Resolved
Install anti-siphon device on Oilywater Separating equipment where over 15ppm stops the bilge pump and sounds alarm. MARPOL 73/78 I/16. Correct prior to next U.S. Port after sailing foreign.
Condition: Unknown
Due 8 March 1999
Resolved 8 March 1999
Fire Fighting
Issued 11 March 1997
Resolved
Remove hold back hooks on all engineroom fire doors and maintain in a closed position. Complete prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-2/51
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Engineering
Issued 11 March 1997
Resolved
Secure the loose wiring and junction boxes to oil stop valves on the auxiliary boiler burner assembly prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 74 II-1/27
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997
Engineering
Issued 11 March 1997
Resolved
Provide a class report on repairs made to the M/E J/W pumps. Pumps are experiencing excessive vibrations and are secured with tie down straps. Complete prior to return to a U. S. port._x001C_ SOLAS 74 II-1/28
Condition: Unknown
Due 25 April 1997
Resolved 25 April 1997