MAURY USCG vessel records Sign in
← All vessels

COOL CRAIG

COOL CRAIG is a 1981 freight ship. The Coast Guard has recorded 8 inspections since 1988, most recently in August 2002, along with 53 deficiencies.

Records from 1988 to 2002. Most recent: inspection, 12 August 2002.

Built
1981
Last inspected
12 August 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8118188 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227268
Flag
PANAMA
—
Maury page id
psix-227268

Inspections, by type

…with no type recorded7
Years with a record 8 calendar years (1988–2002)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it2600 - Regulatory (Subpart C or D), Net Ton
4605 - Regulatory (Subpart C or D), Gross Ton
5554 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

12 August 2002 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1660576
23 October 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 294865
25 January 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 424711
12 November 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 397142
23 January 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 374372
8 April 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 361033
29 August 1989 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 332317
14 April 1988 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 322538

Deficiency record · 53

Engineering › Steam System (main)
Issued 12 August 2002 Resolved
Steam line patched to fuel oil tank heating system in forward bulkhead in engine room. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Temp deflector shield installed, perm repairs directed by CLASS in D/D, Oct 02
Construction/Loadline › Hull
Issued 12 August 2002 Resolved
Forward engine room lower level bulkhead. Fractures on vent stiffeners from to port # 5 & 6 and to starboard # 5 & 6. LEGACY COMPONENT DESC: Stiffener
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Received Class report indicating repairs to be made at D/D Oct 02.
Lifesaving › Lifebuoys
Issued 12 August 2002 Resolved
Light bulb on ring buoy light (portside) beneath lifeboat is inoperable. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Light repaired.
Accommodation/Occupational Safety › Messroom
Issued 12 August 2002 Resolved
Pest/Bug infestation in galley.
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 16 August 2002
Resolution: Sighted receipt from pest control company indiacting that treatment has been completed.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002 Resolved
Containment - Improper plugs for containment throughout vessel. Wood plugs and rags in use as plugs. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Mechanical plugs installed in all containment.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002 Resolved
excessive oil in bilges - fire hazard in engine room. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: All standing oil removed from bilges, discharged to vac truck.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002 Resolved
OWS - Oil visible on valve at skin of ship and on discharge side of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 August 2002
Resolution: Demonstrated proper operation of system, no oil residue visible in dischage line.
Fire Fighting › Emergency Fire Pumps
Issued 12 August 2002 Resolved
Fuel oil leak in line from tank to emergency fire pump engine fuel. Injection aslo leaking.
Action required: 705 - Other - as specified
Resolved 14 August 2002
Fire Fighting › Emergency Fire Pumps
Issued 12 August 2002 Resolved
Emergency fire pump not producing pressure. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 12 August 2002 Resolved
Broken handrail ladder to lower engine room. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 12 August 2002 Resolved
Patched line - S.W. to refer cond.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Received Class Report indicating repair to be conducted at D/D Oct 02.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 August 2002 Resolved
Patch on top of CO2 storage room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2002
Lifesaving › Launching Appliances
Issued 12 August 2002 Resolved
Starboard side lifeboat davit various shieve mounts and tricing line bitt wasted. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Permanent repairs conducted, winesed satisfactory operational tes.
Operations/Management › Drills/Instruction
Issued 12 August 2002 Resolved
Conduct Fire and Boat drills. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Witnessed satisfactory fire and boat drills.
Lifesaving › Lifeboat
Issued 12 August 2002 Resolved
PORT LIFEBOAT, STARBOARD BOW, IMPROPER HULL REPAIR, AREA REPAIRED DELAMINATING AND CAVING IN. HAVE CLASS SURVEYOR PROVIDE REPORT AND REPAIR PROCEDURE RECCOMMENDATION LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Witnessed satisfactory permanent repairs conducted by Class approved repair technician, tested by sounding with mallet and found sat.
Electrical
Issued 23 October 2001 Resolved
FIT ALL LIGHTS THROUGHOUT ENGINE ROOM AND STEERING GEAR SPACE WITH PROTECTIVE COVERS (GUARDS).
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: Sighted all fitted with covers.
Accommodation/Occupational Safety
Issued 23 October 2001 Resolved
REPAIR OR REPLACE FREEZER AND REEFER DOOR LATCHES. PROVE PROPER OPERATION FROM BOTH INSIDE AND OUTSIDE THE DOORS.
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: Tested all and found satisfactory
Fire Fighting
Issued 23 October 2001 Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN THROUGHOUT VESSEL AND PROVE PROPER FIREMAIN PRESSURE TO ATTENDING CLASS SURVEYOR AND U.S. COAST GUARD INSPECTOR PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Navigation
Issued 23 October 2001 Resolved
PROVIDE TECHNICIAN REPORT UPON COMPLETION OF REPAIRS TO GYRO COMPASS PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Navigation
Issued 23 October 2001 Resolved
PROVIDE CORRECTED CHART OF PENSACOLA, FLORIDA PRIOR TO DEPARTURE FROM PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 23 October 2001 Resolved
REMOVE WELD FROM STEERING GEAR COMPARTMENT EMERGENCY ESCAPE HATCH AND ENSURE PROPER HATCH OPERATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 23 October 2001 Resolved
REPAIR OR RENEW AS ORIGINAL, WASTED STEP ON PORT SIDE MAIN DECK LEADING TO FOCSLE.
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: New step installed.
Documentation
Issued 25 January 1999 Resolved
Provide flag state letter accepting officers licences from non flag state. STCW 78 II/2 III/2._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Documentation
Issued 25 January 1999 Resolved
Provide training manual in languauge understood by the crew specific._x001C_ SOLAS 74 (amended) III/18.2.51.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 25 January 1999 Resolved
Service starboard liferaft a provide report._x001C_ SOLAS 74 (unamended) III/8.35
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999 Resolved
Repair leak on MSD - Marine Sanitation device_x001C_ MARPOL IV Reg 4.5.6.7.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Engineering
Issued 25 January 1999 Resolved
Repair or replace sea water pump in engine room._x001C_ SOLAS 74 (amended) II-2/21._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999 Resolved
Clean oil residue from entire engine room, main engine, generators, & all piping throughout engine room. Pump to approved reception facility and provide receipt._x001C_ MARPOL 73/78 Annex 1/17.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999 Resolved
Demonstrate proper fire drill._x001C_ SOLAS 74 (amended) III/18.3 10-3.13_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999 Resolved
Provide proper lighting & handrail leading to boatswain storage._x001C_ ILLO 16711.12_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999 Resolved
Provide complete International Shore connection including washers._x001C_ SOLAS 74 (unamended) II-2/5.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Engineering
Issued 25 January 1999 Resolved
Demonstrate proper operation of OWS and provide replacement filters on board._x001C_ MARPOL 73/78 Annex I/16.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999 Resolved
Repair exhaust leak on emergency fire pump._x001C_ SOLAS 74 (unamended) II-2/52._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Navigation
Issued 25 January 1999 Resolved
Provide class report attesting to proper operation hard port to hard starboard steering in required 28 seconds._x001C_ SOLAS 74 (unamended) II/29.30._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Documentation
Issued 25 January 1999 Resolved
Provide watchlist on bridge posted._x001C_ STCW VIII/I
Condition: Unknown
Due 9 February 1999
Resolved 2 February 1999
Lifesaving
Issued 25 January 1999 Resolved
Demonstrate proper abandon ship drill._x001C_ Solas 74 (amended) III 18.3 4-3.9
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Navigation
Issued 23 January 1995 Resolved
A VIO 33CFR 164.33 IN THAT THE VESSEL DID NOT HAVE O/B U.S.COAST PILOT VOL.3
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995 Resolved
PORT LIFE BOAT SEAT BROKEN
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Fire Fighting
Issued 23 January 1995 Resolved
A VIO SOLAS CHAP II-2 VESSEL NEEDS TO REPLACE 3 FIRE HOSES
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995 Resolved
LINE THROWING APPLIANCE
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995 Resolved
LIFE BOATS MISSING CAPACITY LABEL
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Documentation
Issued 8 April 1992 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992 Resolved
CHARTS WERE NOT CURRENTLY CORRECTED AS REQUIRED BY 33 C.F.R. 164.33(a)(1)(ii).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992 Resolved
CORRECTIONS IN U.S. COAST PILOT NOT CURRENT AS REQUIRED BY 33 C.F.R. 164.33(a)(2)(i).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Unknown
Issued 8 April 1992 Resolved
NO MARPOL PLACARDS WERE DISPLAYED AS REQUIRED BY 33 C.F.R. 151.9.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992 Resolved
NO CURRENT TIDAL CURRENT TABLES ON BOARD AS REQUIRED BY 33 C.F.R. 164.33(a)(3)(ii).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992 Resolved
CORRECTIONS IN LIGHTLIST NOT CURRENT AS REQUIRED BY 33 C.F.R. 164.33(a)(3)(ii)
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 29 August 1989 Resolved
N.O.S. CHARTS 18720,18740,18746,18749 & 18751 NOT CORRECTED TO DATE. CORRECTED CHARTS ARE A REQUIREMENT OF 33CFR164.33(A)(1)(II).
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Navigation
Issued 29 August 1989 Resolved
U.S. COAST PILOT 1988 ED. & COAST GUARD LIGHT LIST VOL 6. 1988 ED. NOT CORRECTED TO DATE. A CORRECTED COAST PILOT & LIGHT LIST ARE REQUIREMENTS OF33CFR164.33(A)(2)(I) & (II).
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Navigation
Issued 14 April 1988 Resolved
A VIO OF 33CFR164.30 IN THAT U.S. CHARTS 12214 & 12311 USED BY THE VSL WERENOT CORRECTED TO NTM 48/87 WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO WILMINGTON,DE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 14 April 1988 Resolved
A VIO OF 33CFR164.30 IN THAT THE USCG LIGHT LIST,VOL.1 USED BY THE VSL WAS NOT CORRECTED TO NTM 52/87 WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO WILMINGTON,DE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 14 April 1988 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988 Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. COAST PILOT,VOL.3 OR ITS FOREIGN EQUIV WHICH WAS REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPENTO WILMINGTON,DE.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.