Records from 1988 to 2002. Most recent: inspection, 12 August 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering › Steam System (main)
Issued 12 August 2002
Resolved
Steam line patched to fuel oil tank heating system in forward bulkhead in engine room. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Temp deflector shield installed, perm repairs directed by CLASS in D/D, Oct 02
Construction/Loadline › Hull
Issued 12 August 2002
Resolved
Forward engine room lower level bulkhead. Fractures on vent stiffeners from to port # 5 & 6 and to starboard # 5 & 6. LEGACY COMPONENT DESC: Stiffener
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Received Class report indicating repairs to be made at D/D Oct 02.
Lifesaving › Lifebuoys
Issued 12 August 2002
Resolved
Light bulb on ring buoy light (portside) beneath lifeboat is inoperable. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Light repaired.
Accommodation/Occupational Safety › Messroom
Issued 12 August 2002
Resolved
Pest/Bug infestation in galley.
Condition: Improper/Lack of Maintenance
Due 12 September 2002
Resolved 16 August 2002
Resolution: Sighted receipt from pest control company indiacting that treatment has been completed.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002
Resolved
Containment - Improper plugs for containment throughout vessel. Wood plugs and rags in use as plugs. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Mechanical plugs installed in all containment.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002
Resolved
excessive oil in bilges - fire hazard in engine room. LEGACY COMPONENT DESC: Bilge Monitor
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: All standing oil removed from bilges, discharged to vac truck.
Pollution Prevention/Response › Prevention Equipment
Issued 12 August 2002
Resolved
OWS - Oil visible on valve at skin of ship and on discharge side of OWS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 15 August 2002
Resolution: Demonstrated proper operation of system, no oil residue visible in dischage line.
Fire Fighting › Emergency Fire Pumps
Issued 12 August 2002
Resolved
Fuel oil leak in line from tank to emergency fire pump engine fuel. Injection aslo leaking.
Action required: 705 - Other - as specified
Resolved 14 August 2002
Fire Fighting › Emergency Fire Pumps
Issued 12 August 2002
Resolved
Emergency fire pump not producing pressure. LEGACY COMPONENT DESC: Pressure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 12 August 2002
Resolved
Broken handrail ladder to lower engine room. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 12 August 2002
Resolved
Patched line - S.W. to refer cond.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Received Class Report indicating repair to be conducted at D/D Oct 02.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 12 August 2002
Resolved
Patch on top of CO2 storage room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 August 2002
Lifesaving › Launching Appliances
Issued 12 August 2002
Resolved
Starboard side lifeboat davit various shieve mounts and tricing line bitt wasted. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Permanent repairs conducted, winesed satisfactory operational tes.
Operations/Management › Drills/Instruction
Issued 12 August 2002
Resolved
Conduct Fire and Boat drills. LEGACY COMPONENT DESC: Fire
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Witnessed satisfactory fire and boat drills.
Lifesaving › Lifeboat
Issued 12 August 2002
Resolved
PORT LIFEBOAT, STARBOARD BOW, IMPROPER HULL REPAIR, AREA REPAIRED DELAMINATING AND CAVING IN. HAVE CLASS SURVEYOR PROVIDE REPORT AND REPAIR PROCEDURE RECCOMMENDATION LEGACY COMPONENT DESC: Hull
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2002
Resolution: Witnessed satisfactory permanent repairs conducted by Class approved repair technician, tested by sounding with mallet and found sat.
Electrical
Issued 23 October 2001
Resolved
FIT ALL LIGHTS THROUGHOUT ENGINE ROOM AND STEERING GEAR SPACE WITH PROTECTIVE COVERS (GUARDS).
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: Sighted all fitted with covers.
Accommodation/Occupational Safety
Issued 23 October 2001
Resolved
REPAIR OR REPLACE FREEZER AND REEFER DOOR LATCHES. PROVE PROPER OPERATION FROM BOTH INSIDE AND OUTSIDE THE DOORS.
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: Tested all and found satisfactory
Fire Fighting
Issued 23 October 2001
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN THROUGHOUT VESSEL AND PROVE PROPER FIREMAIN PRESSURE TO ATTENDING CLASS SURVEYOR AND U.S. COAST GUARD INSPECTOR PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Navigation
Issued 23 October 2001
Resolved
PROVIDE TECHNICIAN REPORT UPON COMPLETION OF REPAIRS TO GYRO COMPASS PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Navigation
Issued 23 October 2001
Resolved
PROVIDE CORRECTED CHART OF PENSACOLA, FLORIDA PRIOR TO DEPARTURE FROM PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 23 October 2001
Resolved
REMOVE WELD FROM STEERING GEAR COMPARTMENT EMERGENCY ESCAPE HATCH AND ENSURE PROPER HATCH OPERATION PRIOR TO DEPARTURE FROM THE PORT OF PENSACOLA.
Condition: Unknown
Due 23 October 2001
Resolved 29 October 2001
Construction/Loadline
Issued 23 October 2001
Resolved
REPAIR OR RENEW AS ORIGINAL, WASTED STEP ON PORT SIDE MAIN DECK LEADING TO FOCSLE.
Condition: Unknown
Due 23 November 2001
Resolved 16 August 2002
Resolution: New step installed.
Documentation
Issued 25 January 1999
Resolved
Provide flag state letter accepting officers licences from non flag state. STCW 78 II/2 III/2._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Documentation
Issued 25 January 1999
Resolved
Provide training manual in languauge understood by the crew specific._x001C_ SOLAS 74 (amended) III/18.2.51.
Condition: Unknown
Due 2 February 1999
Resolved 2 February 1999
Lifesaving
Issued 25 January 1999
Resolved
Service starboard liferaft a provide report._x001C_ SOLAS 74 (unamended) III/8.35
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999
Resolved
Repair leak on MSD - Marine Sanitation device_x001C_ MARPOL IV Reg 4.5.6.7.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Engineering
Issued 25 January 1999
Resolved
Repair or replace sea water pump in engine room._x001C_ SOLAS 74 (amended) II-2/21._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999
Resolved
Clean oil residue from entire engine room, main engine, generators, & all piping throughout engine room. Pump to approved reception facility and provide receipt._x001C_ MARPOL 73/78 Annex 1/17.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999
Resolved
Demonstrate proper fire drill._x001C_ SOLAS 74 (amended) III/18.3 10-3.13_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Accommodation/Occupational Safety
Issued 25 January 1999
Resolved
Provide proper lighting & handrail leading to boatswain storage._x001C_ ILLO 16711.12_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999
Resolved
Provide complete International Shore connection including washers._x001C_ SOLAS 74 (unamended) II-2/5.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Engineering
Issued 25 January 1999
Resolved
Demonstrate proper operation of OWS and provide replacement filters on board._x001C_ MARPOL 73/78 Annex I/16.
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Fire Fighting
Issued 25 January 1999
Resolved
Repair exhaust leak on emergency fire pump._x001C_ SOLAS 74 (unamended) II-2/52._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Navigation
Issued 25 January 1999
Resolved
Provide class report attesting to proper operation hard port to hard starboard steering in required 28 seconds._x001C_ SOLAS 74 (unamended) II/29.30._x001C_ _x001C_
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Documentation
Issued 25 January 1999
Resolved
Provide watchlist on bridge posted._x001C_ STCW VIII/I
Condition: Unknown
Due 9 February 1999
Resolved 2 February 1999
Lifesaving
Issued 25 January 1999
Resolved
Demonstrate proper abandon ship drill._x001C_ Solas 74 (amended) III 18.3 4-3.9
Condition: Unknown
Due 25 January 1999
Resolved 2 February 1999
Navigation
Issued 23 January 1995
Resolved
A VIO 33CFR 164.33 IN THAT THE VESSEL DID NOT HAVE O/B U.S.COAST PILOT VOL.3
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995
Resolved
PORT LIFE BOAT SEAT BROKEN
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Fire Fighting
Issued 23 January 1995
Resolved
A VIO SOLAS CHAP II-2 VESSEL NEEDS TO REPLACE 3 FIRE HOSES
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995
Resolved
LINE THROWING APPLIANCE
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Lifesaving
Issued 23 January 1995
Resolved
LIFE BOATS MISSING CAPACITY LABEL
Condition: Unknown
Due 24 January 1995
Resolved 10 February 1995
Documentation
Issued 8 April 1992
Resolved
OIL TRANSFER PROCEDURES INCOMPLETE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992
Resolved
CHARTS WERE NOT CURRENTLY CORRECTED AS REQUIRED BY 33 C.F.R. 164.33(a)(1)(ii).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992
Resolved
CORRECTIONS IN U.S. COAST PILOT NOT CURRENT AS REQUIRED BY 33 C.F.R. 164.33(a)(2)(i).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Unknown
Issued 8 April 1992
Resolved
NO MARPOL PLACARDS WERE DISPLAYED AS REQUIRED BY 33 C.F.R. 151.9.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992
Resolved
NO CURRENT TIDAL CURRENT TABLES ON BOARD AS REQUIRED BY 33 C.F.R. 164.33(a)(3)(ii).
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 8 April 1992
Resolved
CORRECTIONS IN LIGHTLIST NOT CURRENT AS REQUIRED BY 33 C.F.R. 164.33(a)(3)(ii)
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 29 August 1989
Resolved
N.O.S. CHARTS 18720,18740,18746,18749 & 18751 NOT CORRECTED TO DATE. CORRECTED CHARTS ARE A REQUIREMENT OF 33CFR164.33(A)(1)(II).
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Navigation
Issued 29 August 1989
Resolved
U.S. COAST PILOT 1988 ED. & COAST GUARD LIGHT LIST VOL 6. 1988 ED. NOT CORRECTED TO DATE. A CORRECTED COAST PILOT & LIGHT LIST ARE REQUIREMENTS OF33CFR164.33(A)(2)(I) & (II).
Condition: Unknown
Due 29 August 1989
Resolved 29 August 1989
Navigation
Issued 14 April 1988
Resolved
A VIO OF 33CFR164.30 IN THAT U.S. CHARTS 12214 & 12311 USED BY THE VSL WERENOT CORRECTED TO NTM 48/87 WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO WILMINGTON,DE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 14 April 1988
Resolved
A VIO OF 33CFR164.30 IN THAT THE USCG LIGHT LIST,VOL.1 USED BY THE VSL WAS NOT CORRECTED TO NTM 52/87 WHICH WAS REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM CAPE HENLOPEN TO WILMINGTON,DE.
Condition: Unknown
Due 18 January 1995
Resolved 18 January 1995
Navigation
Issued 14 April 1988
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Navigation
Issued 14 April 1988
Resolved
A VIO OF 33CFR164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. COAST PILOT,VOL.3 OR ITS FOREIGN EQUIV WHICH WAS REQ FOR THE VSL'S ROUTE FROM CAPE HENLOPENTO WILMINGTON,DE.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988