MAURY USCG vessel records Sign in
← All vessels

BIRCHGLEN

BIRCHGLEN is a 1983 freight ship. The Coast Guard has recorded 78 inspections since 1984, most recently in May 2012, along with 48 deficiencies and 2 operational controls.

Records from 1984 to 2012. Most recent: inspection, 24 May 2012.

Built
1983
Last inspected
24 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8119273 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227282
Flag
CANADA
—
Maury page id
psix-227282

Inspections, by type

…with no type recorded54
Years with a record 25 calendar years (1984–2012)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11648 - Regulatory (Subpart C or D), Net Ton
22388 - Regulatory (Subpart C or D), Gross Ton
36248 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 78

24 May 2012 ISPS II Exam · Canadian Vsl Safety Exam (D9 only)
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 4320419
10 February 2010 Spot Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3678198
8 January 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3660769
7 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3339976
13 August 2008 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 3296208
19 May 2008 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3211246
3 March 2008 MARPOL Annex V Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3157353
13 February 2008 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3146734
6 January 2008 Random ISPS/MTSA/PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3124844
17 November 2007 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3100873
17 November 2007 Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3104522
22 July 2007 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3003144
2 April 2007 Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 3041166
13 January 2007 PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2854590
17 October 2005 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 2515876
23 April 2005 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2336563
23 April 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2336570
19 October 2004 NPV Safety Exam
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 2223990
25 July 2004 ISPS I Exam · ISPS II Exam
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2143947
8 June 2004 Deficiency Check
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2092511
26 May 2004 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2078908
20 December 2003 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 1968725
10 November 2003 MARPOL Annex I Examination · Administrative Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1945049
3 November 2003 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1941357
25 October 2003 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1936688
22 September 2003 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1910186
18 September 2003 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1908678
17 September 2003 MARPOL Annex V Examination · Examination of Repairs · Annual Inspection · MARPOL Annex I Examination · Security Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1906874
3 December 2002 Deficiency Check
Physical examination · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 1713880
14 May 2002 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1616479
9 May 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1614327
22 March 2002 Annual Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1597128
22 June 2001 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 291144
3 May 2001 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 475623
24 July 2000 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 280253
31 May 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 278388
12 April 1999 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 427244
5 April 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 427219
30 March 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 426941
16 October 1998 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 421597
11 May 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 415743
16 March 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 413767
8 December 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 410749
17 April 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 205253
17 April 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 402696
17 April 1997 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 752754
11 April 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 402383
30 September 1996 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 395981
20 April 1996 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 390374
16 October 1995 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 383848
27 April 1995 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 377670
29 July 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 492104
20 July 1994 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 368612
25 May 1994 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 701407
24 May 1994 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 366936
22 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 461462
13 June 1993 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 165128
28 May 1993 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 358425
25 September 1992 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 493295
23 September 1992 Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1257129
3 June 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 351064
17 April 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 528209
6 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1266731
4 February 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 348651
29 January 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 348391
13 December 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 655239
3 December 1991 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 347343
5 September 1991 Type not recorded
No type recorded · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 345688
15 April 1991 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 343204
30 November 1990 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 340637
11 December 1989 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 333994
4 March 1989 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 539868
11 October 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 326164
18 February 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 321491
15 February 1988 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 514077
27 April 1987 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 315717
5 May 1986 Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 308550
27 November 1984 Type not recorded
No type recorded · MSO MILWAUKEE · USCG Great Lakes District (CGD-GL) · Activity 299099

Deficiency record · 48

Navigation › Collision/Grounding Avoidance › Radar
Issued 10 February 2010 Resolved
Vessel issued LOD 07-10 for an inoperable secondary radar. Radar required to be operational prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 February 2010
Resolution: Received tech report attesting to proper repair of the secondary radar.
Personnel › Certificates/Documents/Licenses › License, Assistant Engineer
Issued 13 August 2008 Resolved
Found the 4th assistant engineers license expired. Subject is not filling a required spot on the safe manning document. Issued a requirement prohibiting 4th engineer form performing any duties requiring a licensed mariner. Subject must renew his Canadian License to the satisfaction on the issuing administration.
Action required: 705 - Other - as specified
Resolved 7 October 2008
Resolution: Rcvd temp Certificate from Transport Canada.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 3 March 2008 Resolved
Logs not being maintained per MARPOL or ships policy. RO to attest to proper implementation of Garbage Management Plan and record keeping.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2008
Resolution: Received satisfactory class report attesting to the proper implementation of GMP and record keeping.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 6 January 2008 Resolved
Vessel did not have receipts for several entries in garbage log where it was recorded that garbage was discharged ashore.
Action required: 705 - Other - as specified
Resolved 6 January 2008
Resolution: Port state control inspectors educated second mate along with the vessels master.
Construction/Loadline › Structures › Door
Issued 6 January 2008 Resolved
Standing water found in paint locker and paint stores. Gaskets on the three doors to these spaces are deteriorated and do not provide a weather tight seal. Gaskets must be replaced to the satisfaction of class.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 14 February 2008
Resolution: Received satisfactory class report attesting to the proper operation of the above deficiency.
Personnel › Certificates/Documents/Licenses › License, GMDSS Radio Operator
Issued 22 July 2007 Resolved
Safe manning document endorsed by flag state requires two licensed GMDSS operators. Only one licensed GMDSS operator is on board. The First Mate's GMDSS license is expired. The Third Mate's GMDSS license is restricted to near coastal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2007
Resolution: Company sent a qualified GMDSS operator to meet vsl prior to departure. CG received fax confirming same.
Engineering › Steering Gear System
Issued 26 May 2004 Resolved
Steering Gear compartment to be cleaned of excessive hydraulic oil.
Due 1 July 2004
Resolved 30 July 2004
Lifesaving › Lifeboat
Issued 17 September 2003 Resolved
Provide proper operation of starboard lifeboat motor and conduct underway operation in presence of USCG inspector. SOLAS 74, Chapter III, Regulation 09. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Replaced parts on engine. Starboard lifeboat motor operational. Conducted test of engine for 15 minutes underway test was satisfactory.
Operations/Management › Drills/Instruction
Issued 17 September 2003 Resolved
Conduct satisfactory fire and abandon ship drills in presence of USCG inspector. SOLAS 74, Chapter XI, Regulation 04; ISM Code 8. LEGACY COMPONENT DESC: Abandon Ship
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Conducted satisfactory fire fighting drill i9n presence of USCG inspector.
Lifesaving › Lifeboat
Issued 17 September 2003 Resolved
Repair and prove proper operation of starboard motor lifeboat limit switches to satisfaction of attending class surveyor. SOLAS 74, Chapter III, Regulation 19. LEGACY COMPONENT DESC: Embarkation/Disembarkation Capabilities
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Both limit switches replaced and tested. Class and USCG attended test. Reference LLoyd''s Interim Certificate Provisional Issue.
Electrical › Lighting (emergency)
Issued 17 September 2003 Resolved
Repair emergency lighting and prove proper operation at lifeboat and life raft embarkation stations and EDG room to satisfaction of attending class surveyor. SOLAS 74, Chapter II-1, Regulation 26. LEGACY COMPONENT DESC: Lighting Feeder
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Repair completed on emergency lighting. Tested satisfactory for LLoyd''s Surveyor and USCG attendee''s. Initial acceptance noted in Interim Certificate by Class. Complete details will be listed in later surveyor''s report.
Electrical › Electric Generation Source (emergency)
Issued 17 September 2003 Resolved
Repair wasted fuel supply tank and return lines to EDG fuel supply tank to satisfaction of attending class surveyor. SOLAS 74, Chapter II-1, Regulation 26. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Approved class shipyard personnel conducted repair. All replaced components tested for leaks and EDG checked for proper operation. Class surveyor and USCG attended test.
Lifesaving › Lifeboat Equipment
Issued 17 September 2003 Resolved
Renew expired pyrotechnics in both lifeboats. SOLAS 74, Chapter III, Regulation 30. LEGACY COMPONENT DESC: Hand Flare
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Pyrotechnices in both lifeboats replaced. Verified by USCG inspector.
Fire Fighting › Fire Hydrants
Issued 17 September 2003 Resolved
Provide proper fire hose and hydrant connections on main deck stations. SOLAS 74, Chapter II-2, Regulation 32. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: All Fire hose and hydrant connections are in proper working order. Tested and checked after fire drill while fire fighting system charged.
Pollution Prevention/Response › Prevention Equipment
Issued 17 September 2003 Resolved
Ensure OWS alarm is operational and prove proper operation to attending class surveyor. MARPOL 73/78, ANNEX 1, Regulation 16. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Class is requiring that the OWS not be used until tech representative at next port call can fix the problem and give the crew training on the system. Alarm is working on OWS. Error code flashes & system alarm sounds after running diagnostic test.
Lifesaving › Lifeboat
Issued 17 September 2003 Resolved
Provide enough fuel for motor lifeboat for 24 hours continuous operation. SOLAS 74, Chapter III, Regulation 09. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Tank filled to 95% capacity. Verified by USCG inspector.
Lifesaving › Lifeboat Equipment
Issued 17 September 2003 Resolved
Provide proper amount of drinking water per person in port lifeboat. SOLAS 74, Chapter III. LEGACY COMPONENT DESC: Water/Water Receptacles
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2003
Resolution: Lifeboat tank cleaned and flushed tank filled with water. Two additional five gallon wter containers onboard lifeboat.
Deck/Cargo › Holds/Tanks
Issued 17 September 2003 Resolved
Class surveyor to address distorted stiffener brackets in cargo hold #4 Starboard side within next 60 days. ILLC 66 Annex 1 LEGACY COMPONENT DESC: Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 10 November 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 17 September 2003 Resolved
Renew forward ladder rungs where broken in cargo hold #4 and renew handrails at top aft landing where missing and wasted within 60 days. ILLC 66 Annex 1/15. LEGACY COMPONENT DESC: Hand Grab
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 10 November 2003
Resolution: Ladder rungs replaced with new ones.
Deck/Cargo › Ballast
Issued 17 September 2003 Resolved
Throughout main deck renew ballast vent and fuel oil vent covers where wasted and holed. Replace within next 60 days. ILLC 66 1/15 LEGACY COMPONENT DESC: Vents
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 29 June 2004
Accommodation/Occupational Safety › Ventilation
Issued 17 September 2003 Resolved
Ensure battery room and emergency generator room vent closures seal and close properly within the next 30 days. ILLC 66 Annex 1/15 LEGACY COMPONENT DESC: Vent Closures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Resolution: Vent Closures operate freely
Deck/Cargo › Holds/Tanks
Issued 17 September 2003 Resolved
Class surveyor address fracture in aft-port coaming radius to cargo hold #6 within next 60 days. ILLC Annex 1/1 LEGACY COMPONENT DESC: Coaming
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 29 June 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 17 September 2003 Resolved
Renew Busted/ broken deck handrails within next 60 days. ILLC 66 Annex 1/15 LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 29 May 2004
Engineering › Fuel Oil Service System
Issued 17 September 2003 Resolved
Clean excessive fuel oil leakage and repair pump seal to bow thruster prime mover within next 30 days. SOLAS 74/II-2/33 LEGACY COMPONENT DESC: Pump
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Fire Fighting › Means of Escape
Issued 17 September 2003 Resolved
Remove hawser line from forward escape ladder hatch on bow within next 2 days. SOLAS 74/II-2/53 LEGACY COMPONENT DESC: Stairways
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 18 September 2003
Resolution: Hawser line removed and signs posted that no line is to be stowed there. USCG inspector attended.
Accommodation/Occupational Safety › Ventilation
Issued 17 September 2003 Resolved
Free up paint locker vent closure device within next 2 days. SOLAS 74/ II-2/ 51 LEGACY COMPONENT DESC: paint locker vent closure
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 18 September 2003
Resolution: Paint locker vent closure device is working properly making a complete seal. witnessed by USCG inspector.
Construction/Loadline › Structures
Issued 17 September 2003 Resolved
Remove improper deck drain line in forward paint locker and replace with hard pipe within next 30 days. SOLAS 74/ II-2/ 51 LEGACY COMPONENT DESC: Scupper
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Lifesaving › Lifebuoys
Issued 17 September 2003 Resolved
Provide proper placement of retro-reflective tape on ring buoys as needed within next 30 days. SOLAS 74/ III/ 30 LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 29 May 2004
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 17 September 2003 Resolved
Provide up to date and detailed Fire Control Plan within next 60 days to satisfaction of class society. SOLAS 74/ II-2/20 LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 17 November 2003
Resolved 15 July 2004
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 17 September 2003 Resolved
Properly secure overhead light fixture wiring in staterooms to prevent electrical injury. Fix within next 30 days. SOLAS 74/II-1/27 LEGACY COMPONENT DESC: Berth
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Navigation › Piloting/Steering
Issued 17 September 2003 Resolved
Repair port gyro repeater and prove proper operation to satisfaction of class within next 30 days. SOLAS 74/ V/ 12 LEGACY COMPONENT DESC: Gryo Compass Repeater
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Resolution: Gyro repeater within 1 degree of primary gyro.
Pollution Prevention/Response › Prevention Equipment
Issued 17 September 2003 Resolved
Provide oil containment plugs where missing and plugs that mechanically fit to prevent discharge of oil. MARPOL 73/78 Annex 1/9 LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 18 September 2003
Resolution: Plugs provided and installed properly. attending USCG inspector verified.
Lifesaving › Lifejacket/PFD (General)
Issued 17 September 2003 Resolved
Stencil life jackets with vessel's name throughout as needed with the next 30 days. SOLAS 74/ III/ 19 LEGACY COMPONENT DESC: Marking
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Lifesaving › Lifeboat
Issued 17 September 2003 Resolved
Replace leaking and deteriorated lifeboat storm oil containers within the next 30 days. SOLAS 74/ III/ II LEGACY COMPONENT DESC: Carriage Requirement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Construction/Loadline › Structures
Issued 17 September 2003 Resolved
Crop and renew motor lifeboat aft platform where wasted to satisfaction of class within next 30 days. SOLAS 74/1/19 LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Resolution: Platform replaced.
Fire Fighting › Combustible Materials
Issued 17 September 2003 Resolved
Remove combustible meterials from behind emergency generator switchboard within next 2 days. SOLAS 74/II-1/ 27 LEGACY COMPONENT DESC: Facings/Mouldings/Decorations/Veneers
Action required: 705 - Other - as specified
Due 19 September 2003
Resolved 18 September 2003
Resolution: All combustible materials were removed from behind emergency generator switchboard. USCG inspector verified.
Documentation › Safety/Response Plans/Programs
Issued 17 September 2003 Resolved
Provide Fire Plan and weather tight container outside deckhouse to satisfaction of class. Fix within next 30 days SOLAS 74/II-20 LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 10 November 2003
Resolution: Container replaced.
Deck/Cargo › Holds/Tanks
Issued 17 September 2003 Resolved
Replace steel cover on main deck to #3 port ballast tank to satisfaction of class within next 30 days. ILLC Annex 1/ 15 LEGACY COMPONENT DESC: Hatch
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 October 2003
Resolved 29 May 2004
Fire Fighting › Combustible Materials
Issued 17 September 2003 Resolved
Clean out paint locker and arrange/stow flammables properly. SOLAS 74/VII/6 LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 18 September 2003
Resolution: Paint locker was cleaned and organized. USCG attended
Engineering › Shafting/Propeller Arrangements
Issued 9 May 2002 Resolved
CPP mechanism damaged, limiting engine power to 75%. Vessel operating as fixed pitch. Directional control fin on Kort Nozzle was missing and has since been replaced. LEGACY COMPONENT DESC: Propeller (controllable pitch)
Action required: 705 - Other - as specified
Due 31 August 2002
Resolved 3 December 2002
Resolution: CPP repaired and tested sat by class on 01OCT02.
Fire Fighting
Issued 4 February 1992 Resolved
All of the vessels extinguishers had not been inspected in over 15 months.
Condition: Unknown
Due 14 September 1992
Resolved 14 September 1992
Navigation
Issued 3 December 1991 Resolved
VESSEL MISSING CURRENT EDITION OF U.S. COAST PILOT.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Navigation
Issued 3 December 1991 Resolved
MISSING CURRENT EDITIONS OF CHARTS #14882,14883,14963,14968,14975.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Engineering
Issued 11 December 1989 Resolved
NO LINE DIAGRAM OF TRANSFER PIPING, AS REQUIRED UNDER 33 CFR 155.750(A)(2)(I)
Condition: Unknown
Due 28 June 1990
Resolved 11 December 1989
Navigation
Issued 11 October 1988 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE USCG LIGHT LISTS (VOL.1&2) USED BYTHE VSL WERE NOT CURRENTLY CORRECTED UP THRU NTMS 28/88.
Condition: Unknown
Due 28 May 1993
Resolved 28 May 1993
Navigation
Issued 11 October 1988 Resolved
A VIOLATION OF 33 CFR 164.30 IN THAT THE U.S. CHARTS 12274, 12277, 12278, USED BY THE VSL WERE NOT CORRECTED UP THRU NTMS 29/88.
Condition: Unknown
Due 29 January 1996
Resolved 29 January 1996
Navigation
Issued 27 April 1987 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Navigation
Issued 27 April 1987 Resolved
DURING AN ANNUAL EXAM OF THE VSL IT WAS FOUND THAT IMPROPER LOGGING OF THE PREARRIVAL TEST HAD BEEN MADE AS REQUIRED BY 33 CFR 164.11(Q).
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.