Records from 1984 to 2000. Most recent: inspection, 14 September 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 21
14 September 2000
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1054599
10 September 2000
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 282264
10 September 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 822583
15 December 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410864
15 December 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 783138
14 November 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 410259
11 April 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 402381
11 April 1997
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1107360
12 November 1995
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 880737
11 October 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 383755
11 October 1995
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1192966
5 October 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 867668
18 November 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 362494
10 November 1993
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 362362
8 November 1993
Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1460665
23 March 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 905488
11 January 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1198599
29 November 1988
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 327102
29 November 1988
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1206463
21 August 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 444262
26 December 1984
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 517208
Electrical
Issued 15 December 1997
Resolved
PROVIDE NON-CONDUCTIVE HAND RAILS TO POWER DISTRIBUTION PANEL IN EMERGENCY GENERATOR ROOM TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYORS REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Deck/Cargo
Issued 15 December 1997
Resolved
CROP & RENEW CARGO PIPE SECTION PORT SIDE BY 3P TANK ABOVE DISCHARGE BOOSTER PUMP, ABOVE BELTED FLANGE, TEMPORARY REPAIR PATCH NOTED. (MARKED WITH 362). CORRECT TO SATISFACTION OF CLASS. PROVIDE LOCAL U.S. COAST GUARDWITH SATISFACTORY CLASS SURVEYOR'S REPORT.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Navigation
Issued 15 December 1997
Resolved
REPAIR LEAK IN STEERING GEAR ROOM LOCAL CONTROL SELINIOD VALVE ON STARBOARDPUMP. CORRECT TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Fire Fighting
Issued 15 December 1997
Resolved
REPAIR NO.1 FIRE PUMP TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Fire Fighting
Issued 15 December 1997
Resolved
ADJUST OR REPLACE PACKING GLAND TO NO.3 FIRE PUMP TO SATISFACTION OF CLASS.PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Lifesaving
Issued 15 December 1997
Resolved
LABEL ALL LIFEJACKETS WITH VESSELS NAME TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYORS REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 15 December 1997
Resolved
CONDUCT REPAIRS & MAKE WEATHERTIGHT STARBOARD SIDE DOOR TO COMPRESSOR ROOM.CORRECT TO SATISFACTION OF CLASS. PROVIDE LOCAL U.S. COAST GUARD WITH SATISFACTORY CLASS SURVEYOR'S REPORT._x001C_
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 15 December 1997
Resolved
ADJUST WATER TIGHT DOOR PORT SIDE TO ELECTRIC MOTOR ROOM. CORRECT TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 15 December 1997
Resolved
REPLACE/REPAIR SENCOND DOOR (STEEL) PORT SIDE TO ELECTRIC MOTOR ROOM. (DOESNOT SEAL & MISSING DOOR KNOB & LOCKING MECHANISM). CORRECT TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Electrical
Issued 15 December 1997
Resolved
PROPERLY INSTALL & SECURE POWER PANEL GUAGES IN ELECTRIC MOTOR ROOM. CORRECT TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Navigation
Issued 15 December 1997
Resolved
ADJUST/REPAIR STEERING GEAR RUDDER ANGLE INDICATOR. OFF BY 5 DEGREES. CORRECT TO SATISFACTION OF CLASS. PROVIDE SATISFACTORY CLASS SURVEYOR'S REPORT TO LOCAL U.S. COAST GUARD.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Unknown
Issued 11 April 1997
Resolved
RELABEL INERT GAS SYSTEM ALARM PANEL AS REQUIRED BY SOALS 74 REG 62 19.1. CORRECT BY 30 APR 97 TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Unknown
Issued 11 April 1997
Resolved
PROOF PROPER OPERATION OF GAS DETECTION SYSTEM AS REQUIRED BY GAS CARRIER CODE 83.3.6. CORRECT PRIOR BY 30 APR 97 TO SATISFACTION OF CLASS SOCIETY.
Condition: Unknown
Due 21 November 1997
Resolved 21 November 1997
Documentation
Issued 11 October 1995
Resolved
Ensure MARPOL plan has preamble and introduction iaw 33CFR151.
Condition: Unknown
Due 11 November 1995
Resolved 27 November 1995
Documentation
Issued 8 November 1993
Resolved
Provide on board a copy of 46 Code of Federal Regulations Parts 34, 35, 153and 154 as required by 46 CFR Part 153.905.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Electrical
Issued 8 November 1993
Resolved
Provide electrical grade mat or grating in accordance with SOLAS 74 ChapterII-1 Reg. 45.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Lifesaving
Issued 8 November 1993
Resolved
Provide detection tubes for portable toxic gas detectors required by the Gas Carrier Code for Existing Ships Regulation 13.6.12. To be completed to the satifaction of the class society prior to cargo operations at the next U.S. Port. Provide copy of class society report to the cognizant OCMI.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Deck/Cargo
Issued 8 November 1993
Resolved
Test portable cargo hoses and mark in accordance with 46 CFR Part 153.940. To be completed prior to use of hoses for cargo operations at next U.S. Port.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Electrical
Issued 8 November 1993
Resolved
Place emergency starting batteries in proper battery boxes.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Documentation
Issued 8 November 1993
Resolved
Apply load line markings to vessel in accordance with loadline certificate.To be completed to the satisfaction of the classification society prior to cargo operations at next U.S. Port. Provide copy of classification society report to the cognizant Officer in Charge Marine Inspection.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993
Lifesaving
Issued 8 November 1993
Resolved
Prior to carrying anhydrous ammonia provide three sets of safety equipment required by the Gas Carrier Code for Existing Ships Regulation 17.2.3.
Condition: Unknown
Due 8 November 1993
Resolved 8 November 1993