Records from 1985 to 1999. Most recent: inspection, 2 February 1999.
Inspection history · 19
2 February 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 425299
12 November 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 422474
4 September 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 4772
3 June 1998
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 417119
3 January 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 411399
15 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396412
1 October 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 395916
26 June 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 337858
14 September 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 482302
28 February 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 524116
11 February 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 328819
14 November 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 528161
17 February 1988
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 321426
7 October 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 318901
13 June 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 309450
18 December 1985
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 526398
29 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 302202
13 May 1985
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 301905
6 May 1985
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 301855
Accommodation/Occupational Safety
Issued 2 February 1999
No resolution recorded
MAKE REPAIRS TO MSD, SYSTEM INOPERABLE (TYPE III ARRANGEMENT AS TEMPORARY).
Condition: Unknown
Due 10 February 1999 — due date passed with no resolution recorded
Documentation
Issued 2 February 1999
Resolved
PROVIDE VALID CARGO SHIP SAFETY RADIO CERTIFICATE.
Condition: Unknown
Due 3 February 1999
Resolved 30 April 1999
Engineering
Issued 2 February 1999
No resolution recorded
SALT WATER PIPING TO LUBE OIL COOLER FOR GENERATOR NO. 3 WASTED.
Condition: Unknown
Due 5 March 1999 — due date passed with no resolution recorded
Electrical
Issued 2 February 1999
No resolution recorded
GENERATOR NO. 1 INOPERABLE (CLASS REPORT ISSUED TO REPAIR).
Condition: Unknown
Due 15 April 1999 — due date passed with no resolution recorded
Electrical
Issued 2 February 1999
No resolution recorded
UNABLE TO SHOW PROPER OPERATION OF REVERSE POWER RELAY TO SHIP GENERATOR NO. 3.
Condition: Unknown
Due 15 April 1999 — due date passed with no resolution recorded
Accommodation/Occupational Safety
Issued 2 February 1999
Resolved
REPAIR MSD TO PROPER WORKING CONDITION, REMOVE SEWAGE FROM BILGE, CLASS TO ATTEND AND PROVE PROPER OPERATION.
Condition: Unknown
Due 3 February 1999
Resolved 30 April 1999
Electrical
Issued 2 February 1999
Resolved
CLASS TO PROVIDE REPORT ON PORTABLE GENERATOR INSTALLATION.
Condition: Unknown
Due 3 February 1999
Resolved 30 April 1999
Lifesaving
Issued 12 November 1998
Resolved
PROVE PROPER OPERATION OF ALL RING BUOY LIGHTS._x001C_ SOLAS 74(AMENDED) REG III/19.2
Condition: Unknown
Due 30 April 1999
Resolved 30 April 1999
Deck/Cargo
Issued 3 January 1998
Resolved
Vessel had no dangerous cargo manifest for it's cargo: Cotton, dry NA1365 also Fibers, vegetable UN1373. Provide dangerous cargo manifest in accordance with 49 CFR 176.30.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Deck/Cargo
Issued 3 January 1998
Resolved
Vessel's hazmat employees did not have HAZMAT training as per 49 CFR 176.13. Provide evidence of training.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Documentation
Issued 3 January 1998
Resolved
Provide copy of 49 CFR or current IMDGA manual to prepare Dangerous CArgo Manifest.
Condition: Unknown
Due 30 March 1998
Resolved 30 March 1998
Documentation
Issued 3 January 1998
Resolved
Charts (both BA and US) were more than 2 years out of correction. Cite 74 SOLAS V/20 Vessel detained for this discrepancy.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Documentation
Issued 3 January 1998
Resolved
Vessel's Light List and Coast Pilot out of correction. Cite 74 SOLAS V/20.Vessel detained this date for this descrepancy.
Condition: Unknown
Due 4 January 1998
Resolved 5 January 1998
Unknown
Issued 3 January 1998
Resolved
Lifeboat provisions found unserviceable. Port lifeboat had 33/35 provisions unserviceable. starboard lifeboat had 7/35 provisions unserviceable. Cite: 74 SOLAS III/41.8.12 Vessel detained for this discrepancy.
Condition: Unknown
Due 4 January 1998
Resolved 5 January 1998
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
REMOVE RAGS AND GREASE FROM GALLEY RANGE EXHAUST HOOD VENT. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Navigation
Issued 1 October 1996
Resolved
THIS DISCREPANCY DON'T APPLY TO THIS FREIGHT VESSEL. IT WAS ENTERED AS DEFICIENCY BY ERROR.
Condition: Unknown
Due 1 October 1996
Resolved 3 October 1996
Fire Fighting
Issued 1 October 1996
Resolved
PROVIDE SUPPORT FOR PAINT LOCKER SPRINKLER SYSTEM SUPPLY LINE, SECURE LEAK IWO SCREW PIPE CONNECTION. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
OVERHAUL AFT HOOK TO #1 LIFEBOAT. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
CONDUCT LIFEBOAT DRILL TO SATISFACTION OF CLASS SOCIETY SURVEYOR. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
TEST LIFEBOAT #1 LIMIT SWITCHES. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Electrical
Issued 1 October 1996
Resolved
DEMOSTRATE SATISFACTORY OPERATION OF EMERGENCY DIESEL GENERATOR FUEL TANK REMOTE SHUT OFF VALVE. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
RENEW BROKEN HANDRAIL IWO AFT CRANE & S/S FOSCLE. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Accommodation/Occupational Safety
Issued 1 October 1996
Resolved
RENEW GASKET FOR WATER TIGHT DOOR ON MAIN DECK HOUSE P/S PASSAGE WAY ENTRANCE. ENSURE WATER TIGHT SEAL. DEFICIENCY CLEARED ON 05OCT96 PRIOR TODEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
PROVIDE DOCUMENTATION THAT SMOKE/LIGHT UNITS ON BRIDGE WING LIFE BOUYS ARE WITHIN SERVICE LIFE. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Electrical
Issued 1 October 1996
Resolved
RENEW SUPPORT FOR ELECTRICAL CONDUIT OVERHEAD IWO AFT MAIN DECK P/S ADJACENT TO GALLEY. DEFICIENCY CLEARED ON 05OCT96 PRIOR T0 DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
REPAIR LEAK IN #1 LIFEBOAT IWO S/S FORWARD OF ENGINE. POSSIBLE LEAKING FROM S/S PLUG. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Electrical
Issued 1 October 1996
Resolved
PROVIDE LIGHTS, COVERS AS NEED TO PROTECT ELECTRICAL SYSTEM THROUGH OUT THESHIP. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 16 October 1996
Electrical
Issued 1 October 1996
Resolved
PROVIDE EXPLOSIVE PROOF LIGHT, GASKET, COVERS, AND GUARDS FOR PAINT LOCKER.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 1 October 1996
Resolved
RENEW LOADLINE MARKINGS IN CONTRASTING COLOR TO HULL. CORRECT TO SATISFACTION OF THE CLASS SOCIETY SURVEYOR. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 4 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
LIFERAFT WEAK LINK IMPROPERLY ATTACHED.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Electrical
Issued 1 October 1996
Resolved
ELECTRIC PANEL BY DRY STORES MISSING DOOR.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 1 October 1996
Resolved
PROVIDE PIPING SUPPORT FOR FIRE MAIN ON DECK IWO S/S #1, 2, & 3 CARGO HOLDS.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Fire Fighting
Issued 1 October 1996
Resolved
SECURE LEAKS IN THE FIRE MAIN DRESSER COUPLING IWO #1, 2, & 3 CARGO HOLDS.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Construction/Loadline
Issued 1 October 1996
Resolved
MAKE LOADLINE CLASS SOCIETY MARKING PERMANENT. CORRECT TO SATISFACTION OF CLASSIFICATION SOCIETY SURVEYOR. PROVIDE SATISFACTORY SURVEYOR REPORT TO LOCAL U.S. COAST GUARD. DEFICIENCY CLEARED ON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 4 October 1996
Resolved 16 October 1996
Lifesaving
Issued 1 October 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 1 October 1996
Resolved 17 October 1996
Fire Fighting
Issued 1 October 1996
Resolved
REPLACED WET & FADED FIRE SAFETY PLAN ON P/S MAIN DECK. DEFICIENCY CLEAREDON 05OCT96 PRIOR TO DEPARTURE.
Condition: Unknown
Due 1 October 1996
Resolved 17 October 1996
Navigation
Issued 1 October 1996
Resolved
NEED UPDATED EDITIONS OR CORRECTIONS ON CHARTS, U.S. COAST PILOT, SAILING DIRRECTIONS, CG LIGHT LIST AND INLAND NAV. RULES FOR LOCAL AREA.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Navigation
Issued 1 October 1996
Resolved
DAYLIGHT SIGNALLING LAMP INOPERABLE.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Lifesaving
Issued 1 October 1996
Resolved
EPIRB INOPERABLE. FAILED TO TEST.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Lifesaving
Issued 1 October 1996
Resolved
THE HYDROSTATIC RELEASE FOR THE EPIRB IS BROKEN. EPIRB ISN'T IN THE FREE FLOW ARRANGEMENT.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Unknown
Issued 26 June 1990
Resolved
33CFR156.120(T)(1) THE PERSON IN CHARGE WAS NOT AT THE OIL TRANSFER SITE AND IMMEDIATELY AVAILABLE._x001C_ _x001C_ AUTH:33USC1321 PENALTY:33USC1321
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Documentation
Issued 13 June 1986
Resolved
THE VESSEL DID NOT HAVE THE DATE AND RESULTS OF THE TEST REQUIRED BY 33 CFR156.170
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 June 1986
Resolved
THE VESSEL DID NOT HAVE A COPY OR EXTRACT OF THE ATLANTIC COAST TIDAL CURRENT TABLES OR A FORIEGN EQUIVALENT ON BOARD
Condition: Unknown
Due 13 June 1986
Resolved 13 June 1986
Navigation
Issued 13 May 1985
Resolved
THE VESSEL DID NOT HAVE A CURRENTLY CORRECTED COPY OF OR EXTRACT FROM THE U.S. COAST PILOT OR A FOREIGN EQUIVALENT ON BOARD
Condition: Unknown
Due 13 May 1985
Resolved 13 May 1985
Documentation
Issued 13 May 1985
Resolved
THE VESSEL DID NOT HAVE A RECORD OF THE DATE AND RESULTS OF THE TESTS REQUIRED BY 33CFR156.170
Condition: Unknown
Due 13 May 1985
Resolved 13 May 1985
Navigation
Issued 6 May 1985
Resolved
CHARTS 12326,12327,12349 NOT CORRECTED UP TO DATE THROUGH NTM 85/17
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985
Navigation
Issued 6 May 1985
Resolved
CHART 12334 NOT ON BOARD AND CORRECTED THROUGH NTM 85/17. NO FOREIGN EQUIVALENT ON BOARD.
Condition: Unknown
Due 6 May 1985
Resolved 6 May 1985