MAURY USCG vessel records Sign in
← All vessels

ALTARA CARRIER

ALTARA CARRIER is a 1982 freight ship. The Coast Guard has recorded 34 inspections since 1986, most recently in February 2007, along with 24 deficiencies and 3 operational controls.

Records from 1986 to 2007. Most recent: inspection, 26 February 2007.

Built
1982
Last inspected
26 February 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8130837 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227346
Flag
BAHAMAS, THE
—
Maury page id
psix-227346

Inspections, by type

…with no type recorded19
Years with a record 13 calendar years (1986–2007)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it2739 - Regulatory (Subpart C or D), Net Ton
6183 - Regulatory (Subpart C or D), Gross Ton
6404 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 34

26 February 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2877839
9 July 2005 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2424517
8 May 2005 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2352284
12 April 2005 PII Safety Exam · ISPS II Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2331835
8 February 2005 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2288795
24 August 2004 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2175152
12 August 2004 MARPOL Annex I Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2164300
20 July 2004 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2141756
19 July 2004 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2133327
14 April 2004 MARPOL Annex V Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2044306
9 February 2004 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2004101
19 December 2003 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1965433
28 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1861650
6 July 2003 Security Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1838312
12 June 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1808813
15 April 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1772805
27 January 2003 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1735681
23 September 2002 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1678908
25 June 2002 Special Interest Vessel
Type not classified · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1636549
23 February 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1488644
7 October 2001 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 294266
1 February 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 286436
23 January 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 286229
17 October 1996 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 396460
21 March 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 389049
15 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388913
10 December 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 385638
24 April 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 526682
20 March 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 539104
14 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365508
31 March 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 349734
18 July 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331500
17 July 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 317371
7 July 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 309922

Deficiency record · 24

Fire Fighting › Fire Hoses › Condition
Issued 6 March 2007 Resolved
Focsle deck fire hose found to have a pinhole leak.
Condition: Unknown
Due 6 March 2007
Resolved 6 March 2007
Resolution: Hose replaced during course of the exam.
Electrical › Lighting (service) › Lighting Fixture
Issued 6 March 2007 Resolved
Engine space light fixture missing cover.
Condition: Unknown
Due 6 March 2007
Resolved 6 March 2007
Resolution: Fixture replaced during course of the exam.
Electrical › Lighting (service) › Switch
Issued 6 March 2007 Resolved
Found broken electric fixture at bottom of ladder in the #3 reffer hold A-Deck.
Condition: Unknown
Due 6 March 2007
Resolved 9 March 2007
Resolution: Electric fixture was replaced.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 6 March 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 March 2007
Resolved 9 March 2007
Resolution: Representative from the flag state verified that an application for new chief officer''s license is processing. An interim extension has been granted and an approval letter from flag state will be kept on board with chief officer''s other credentials.
Deck/Cargo › Cargo Refrigeration › General
Issued 6 March 2007 Resolved
Deck pipe for reefer coolant line missing bracket neer # 3 Reefer hold.
Condition: Improper/Lack of Maintenance
Due 6 March 2007
Resolved 9 March 2007
Resolution: Bracket was replaced.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 12 April 2005 Resolved
HAVE CLASS/FLAG ATTEST TO THE STRUCTURAL FIRE INTEGRITY OF THE GALLEY MORE SPECIFIC IS THE OPEN SPACE (USED TO STORE DISHES) IN THE CLASS A BULKHEAD
Action required: 705 - Other - as specified
Due 12 May 2005
Resolved 6 March 2007
Resolution: Dish storage space in Galley has been closed using welded steel cover. Class A Bulkhead has been restored.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 August 2004 Resolved
Vessels #4 port fuel tank was found to be a source of an oil discharge in Dutch Harbor by oil sample analysis. Integrity of this tank is suspect and class must initiate an investigation into the cause and corrective actions necessary and provide a report to the cognizant Captain of the Port prior to returning to U.S. waters.
Action required: 15 - Rectify deficiencies by next port
Due 12 August 2004
Resolved 8 February 2005
Resolution: Received fax report from NKK clearing deficiency.
Engineering › Diesel Engine (propulsion-reduction gear) › Charge Air Cooling
Issued 19 July 2004 Resolved
Vessel must provide a report from a recognized class society attesting to the proper operation of the main engines prior to departure from Dutch Harbor, AK.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 July 2004
Resolved 31 August 2004
Resolution: Witnessed proper operation of the main engine during sea trials in lieu of a class report.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 April 2004 Resolved
Fire Control Plan does not show Class A & B boundaries as required by Solas II-2, Regulation #4. Modify current plan to meet this requirement.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 31 August 2004
Resolved 8 February 2005
Resolution: Received fax report from NKK clearing deficiency.
Personnel › Certificates/Documents/Licenses
Issued 14 April 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2004
Resolution: Received FAX from Flag State granting dispensation for vessel to sail with [name withheld] on board as the Chief Engineer.
Fire Fighting › Fire Main
Issued 19 December 2003 Resolved
Hole in ships firemain, starboard side, aft of catwalk starboard anchor windlass. SOLAS 74 (unamen) ch II-1, Part B, Reg 15. Correct prior to departure. Vessel to fax signed statement attesting to satisfactory repair and operational test. Statement to be signed by vessel master. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 19 December 2003
Resolved 19 December 2003
Resolution: CAPTAIN AND P&I CLUB REP, FAXED A SIGNED STATEMENT THAT PERMANENT REPAIRS WERE CARRIED OUT TO THE SECTION OF LEAKING FIRE MAIN. THE REPAIR HAS BEEN TESTED UNDER WORKING PRESSURE WITHOUT FURTHER LEAKAGE.
Navigation › Piloting/Steering
Issued 15 April 2003 Resolved
VESSEL'S CHARTS USED FOR NAVIGATION WERE FOUND NOT TO BE CORRECTED UP TO DATE. AS REQUIRED BY 33 CFR 164.33 (a) (1) (ii). CURRENT NOTICE TO MARINERS REQUIRED TO BE ONBOARD PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2003
Resolution: RCVD FAX RECEIPT OF PURCHASE FROM THE VSL''S AGENT FOR THE REQUIRED NTM''S, WITH THE MASTER''S SIGNATURE & SHIP''S STAMP. DEF. CLEARED.
Navigation › Piloting/Steering
Issued 15 April 2003 Resolved
THE VESSEL'S MAGNETIC COMPASS LOCATED AT THE MAIN STEERING STAND WAS FOUND TO BE READING 30 DEGREE ABOVE WHAT WAS BEING READ ON THE GYROCOMPASS. AS REQUIRED BY 33 CFR 164.35 (b) and (c). PRIOR TO DEPARTURE FROM PORT. LEGACY COMPONENT DESC: Magnetic Compass
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 April 2003
Resolution: RCVD A FAX COPY OF THE TEC H. RPT FROM THE VSL''S AGENT, W/ THE MASTER''S SIGNATURE & SHIP''S STAMP; STATING THE MAG COMPASS WAS CALIBRATED SATISFACTORY. DEF. CLEARED.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 April 2003 Resolved
LOOSE HAND RAIL (BROKEN) LOCATED IN ENGINE ROOM JUST AFT OF THE CONTROL ROOM, WHERE BOTTLES ARE ATTACHED. ILO 147 VIOLATION. TO BE CORRECTED PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN OR WITHIN 30 DAYS. LEGACY COMPONENT DESC: Deck Rail
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 May 2003
Resolved 12 June 2003
Resolution: HANDRAIL HAS BEEN WELDED AND IS NOW SECURE.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 April 2003 Resolved
NON-CONDUCTIVE MATS ARE MISSING FROM IN FRONT OF THE MAINTANCE SWITCHBOARD FOR CARGO REFRIGERATION, LOCATED IN THE ENGINE ROOM. AS REQUIRED BYSOLAS 74 (UNAMENDED) CH.II/REG.27(a) (ii) TO BE CORRECTED PRIOR TO NEXT U.S. PORT, AFTER SAILING FOREIGN OR WITHIN 30 DAYS. LEGACY COMPONENT DESC: NON-CONDUCTIVE MATS
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 May 2003
Resolved 12 June 2003
Resolution: NON-CONDUCTIVE MATS ARE NOW IN FRONT OF THE SWITCHBOARD.
Fire Fighting › Combustible Materials
Issued 15 April 2003 Resolved
OIL SOAKED LAGGING ON PIPES NEAR FUEL OIL TRANSFER PUMP AND NO.1 MAIN ENGINE FUEL OIL BOOSTER PUMP. LAGGING PRESENTS A FIRE HAZARD AND MUST BE REPLACED WITH NEW MATERIAL. SOLAS 74 UNAMENDED, CH.II-2, REG.51(g) TO BE CORRECTED PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN OR WITHIN 30 DAYS. LEGACY COMPONENT DESC: PIPE LAGGING
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 May 2003
Resolved 12 June 2003
Resolution: OLD OIL SOAKED LAGGING WS TAKEN OUT AND NEW LAGGING WAS IN PLACE.
Engineering › Sea-water System (primary cooling)
Issued 23 September 2002 Resolved
SOFT PATCH ON SEAWATER PIPE TO MAIN REFRIGERATOR CONDENSOR, A VIOLATION OF SOLAS 74/78 II-1/ 26-1. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. *NOTE: VESSEL SCHEDULED FOR DRYDOCK AFTER LEAVING PHILADELPHIA--DEFICIENCY TO BE ADDRESSED AT DRYDOCK. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 October 2002
Resolved 27 January 2003
Resolution: Replaced seawater pipe with new at last drydock.
Engineering › Steam System (main)
Issued 23 September 2002 Resolved
LEAKING STEAM RETURN LINE FROM MAIN ENGINE HEATER TO CONDENSOR FOR BOILERS, A VIOLATION OF SOLAS 74/78 II-1/26-1. CORRECT PRIOR TO NEXT U.S. PORT AFTER SAILING FOREIGN. *NOTE: VESSEL SCHEDULED FOR DRYDOCK AFTER LEAVING PHILADELPHIA--DEFICIENCY TO BE ADDRESSED AT DRYDOCK. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 31 October 2002
Resolved 27 January 2003
Resolution: Replaced steam return line with new pipe at last drydock. System no longer leaking.
Lifesaving
Issued 23 January 2001 Resolved
IMMERSION SUIT ZIPPERS IN BAD CONDITION, IN VIOLATION OF SOLAS 74/78 III/19.2.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Fire Fighting
Issued 23 January 2001 Resolved
FORWARD STARBOARD SIDE FIRE HYDRANT HAS BROKEN VALVE, IN VIOLATION OF SOLAS74/78 II-2/4.
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Accommodation/Occupational Safety
Issued 23 January 2001 Resolved
OVERBOARD DISCHARGE VALVE FOR MARINE SANITATION DEVICE NOT PROPERLY SECURED, IN VIOLATION OF 33 CFR 159.7(b).
Condition: Unknown
Due 1 February 2001
Resolved 1 February 2001
Lifesaving
Issued 21 March 1996 Resolved
SEA PAINTERS IN BOTH LIFE BOATS WERE SECURED BY MEANS OF A SHACKLE WHICH WOULD PREVENT QUICK RELEASE WHEN NEEDED. _x001C_ _x001C_ SOLAS 74 CH-III/REG-11(a)
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Construction/Loadline
Issued 21 March 1996 Resolved
REPAINT LOADLINE UNREADABLE _x001C_
Condition: Unknown
Due 25 March 1996
Resolved 25 March 1996
Navigation
Issued 18 July 1989 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE MOST RECENT ED. OF U.S. TIDAL CURRENT TABLES,OR IT'S FOREIGN EQUIVALENT,AS REQ BY 33 CFR 164.33(A)(3)(II) WAS NOTO/B THE VSL: VSL DID NOT HAVE ANY U.S. TIDAL CURRENT TABLES OR FOREIGN EQUIVALENT O/B. THE MOST CURRENT ED OR U.S. TIDAL TABLES IS DTD 1988
Condition: Unknown
Due 18 July 1989
Resolved 18 July 1989

Ownership record