ALAMO is a 1982 freight ship. The Coast Guard has recorded 52 inspections since 1984, most recently in May 2012, along with 25 deficiencies and 4 operational controls.

Records from 1984 to 2012. Most recent: inspection, 5 May 2012.

Built
1982
Last inspected
5 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8202032 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227361
Flag
HONG KONG
—
Maury page id
psix-227361

Inspections, by type

…with no type recorded31
Years with a record 25 calendar years (1984–2012)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it9049 - Convention (Subpart B), Net Ton
15274 - Convention (Subpart B), Gross Ton
25438 - Dead Weight, Ton
31624 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

5 May 2012 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4297736
1 December 2011 Deficiency Check
Physical examination · Sector North Carolina · USCG East District (CGD-E) · Activity 4199605
2 August 2011 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4098511
1 August 2011 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4098700
23 July 2011 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4091465
18 November 2010 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3890652
20 October 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3348291
26 March 2008 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3167331
25 January 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3136561
23 January 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3134605
20 January 2008 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133408
25 September 2007 MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3065511
8 March 2007 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2883972
17 August 2006 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2751081
31 May 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2666742
1 February 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2577240
3 May 2005 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2348566
4 January 2005 ISM Exam · MARPOL Annex I Examination · Loadline Exam · MARPOL Annex V Examination · ILO-147 Exam · Ballast Water Examination · PII Safety Exam · ISPS III Exam · STCW 95 Exam
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2268703
8 September 2004 PII Safety Exam · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2190028
15 December 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1964173
2 May 2003 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1784847
11 January 2003 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1730110
2 November 2002 MARPOL Annex V Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1700318
22 April 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1607402
16 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1486152
15 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1478976
14 January 2002 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1479908
23 July 2001 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 292248
19 March 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 288215
21 August 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 281406
21 March 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 276008
28 January 1999 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 424914
23 September 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 420673
7 July 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 417848
26 April 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 415166
22 January 1998 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 412043
13 August 1996 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 394134
20 April 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 377306
6 January 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 373863
29 August 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 369585
23 July 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 126756
6 January 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 363557
9 January 1993 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 355555
30 September 1990 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 339603
6 March 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328871
16 March 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 321990
3 June 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316465
25 February 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314557
8 August 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 520944
13 January 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 306403
15 October 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 304777
11 July 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 508382

Deficiency record · 25

Operations/Management › EPA Vessel General Permit (VGP) › 1.5.1-VGP Notice of Intent (NOI)
Issued 2 August 2011 Resolved
0199-Each vessel 79 feet or greater in length are required to have Vessel General Permit (VGP) on board. VGP requires owner/operator to provide training, monitoring, inspections, and reporting of discharges incidental to normal operations. Vessel has no Notice of Intent on-board and neither the Master or crew are familiar with the requirements. 40 CFR 122.2-c [email withheld] [phone withheld]
Action required: 705 - Other - as specified
Due 2 August 2011
Resolved 2 December 2011
Resolution: Master provided proof of the VGP and Notice of Intent was on board.
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 January 2008 Resolved
While operating in Sector New Orleans COTP zone, it was discovered that the vessel's radar was not operational. SECNOLA issued COTP Order M0070-08 and restricted the vessel to the lower Mississippi River above Head of Passes. See Operational Control Activity # 3134605
Action required: 17 - Rectify deficiencies prior to departure
Due 25 January 2008
Resolved 25 January 2008
Resolution: Received tech report from Radio Holland USA satisfying the requirement.
Engineering › Fuel Oil Service System › Settler Tank
Issued 25 September 2007 Resolved
The vessel has the means to drain fuel oil directly into the bilge through a flexable hose from a settling tank. Deficiency rectified on spot.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 25 September 2007
Resolution: The hose was removed
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 September 2007 Resolved
The vessel could not provide evidence of flag state approval for the reconfiguration of the OWS discharge piping. The vessel is required to provide evidence of flag state approval for the OWS piping.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 January 2008
Resolution: Received documentation from Flag State satisfying requirement.
Fire Fighting › Firemans Outfit › Lifeline
Issued 1 February 2006 Resolved
Lifelines for fire party are not fire proof. Replace with SOLAS approved type, to the satisfaction of the Coast Guard within 30 days. Violation of Fire Safety Systems Code Chapter 3 2.1.3
Action required: 705 - Other - as specified
Due 2 March 2006
Resolved 31 May 2006
Resolution: Verified that line was SOLAS approved.
Engineering › Sea-water System (primary cooling) › Piping
Issued 1 February 2006 Resolved
Several salt water leaks were found in the engine room. #1 Fire and general ballast pump suction side, and #2 Salt Water cooling pump discharge side were found to have cement patches installed and not reported to flag state. Violation of SOLAS 74/78 Chapter II-I Regulation 26 1.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 31 May 2006
Resolution: Reviewed satisfactory class report.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 1 February 2006 Resolved
Ships incinerator inoperable main transformer electrical problem. Rectify within 14 days to the satisfaction of the Administration or authorized representative. Violation of 33 CFR 151.23(b)(4).
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 31 May 2006
Resolution: Reviewed satisfactory class report.
Deck/Cargo › Holds/Tanks › Hatch
Issued 1 February 2006 Resolved
#2 Carge hatch, aft, starboard side ram is leaking hydraulic fluid. Rectify within 14 days to the satisfaction of Administration or authorized representative. Violation of SOLAS 74/78 Chapter II-II Regulation 4 1.1
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 31 May 2006
Resolution: Reviewed satisfactory class report.
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 4 January 2005 Resolved
VESSEL DOEN NOT HAVE ONBOARD
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 February 2005
Resolved 3 May 2005
Resolution: Classification report attesting to deficiency being cleared to satisfaction.
Construction/Loadline › Markings › Load Line Mark
Issued 4 January 2005 Resolved
VESSEL NEEDS TO REPAINT LOADLINE AND DRAFT MARKS
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 3 May 2005
Resolution: Classification report attesting to deficiency cleared to satisfaction.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 4 January 2005 Resolved
VESSEL NEEDS TO REPAINT IMO NUMBER ON STERN
Condition: Improper/Lack of Maintenance
Due 4 February 2005
Resolved 3 May 2005
Resolution: Classification report attesting to deficiency cleared to satisfaction.
Deck/Cargo › Cargo Stowage
Issued 15 December 2003 Resolved
HYDRAULIC SUPPLY LINE FOR HATCH COVERS WAS WASTED THROUGH AT #2 CARGO HOLD STARBOARD SIDE (JUBILEE PATCHES). VESSEL IS TO HAVE CLASS SOCIEY ATTEST TO THE REPAIRS AND SUBMIT REPORT TO USCG. LEGACY COMPONENT DESC: HATCH COVERS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 15 December 2003
Resolved 19 December 2003
Resolution: RECEIVED CLASS REPORT FROM ABS. 30 METERS OF WASTED HYDRAULIC LINE WAS CROPPED AND RENEWED. #2 CARGO HOLD HATCH COVERS WERE TESTED AND FOUND SATISFACTORY.
Fire Fighting
Issued 19 March 2001 Resolved
REPLACE MISSING GASKET IN NOZZLE AT FIRE BOX #15.
Condition: Unknown
Due 22 March 2001
Resolved 23 March 2001
Lifesaving
Issued 19 March 2001 Resolved
BOTH STARBOARD AND PORT LIFERAFTS PAINTERS NOT SECURED BY WEAK LINK
Condition: Unknown
Due 20 March 2001
Resolved 23 March 2001
Lifesaving
Issued 19 March 2001 Resolved
STARBOARD LIFERAFT MISSING HYDROSTATIC RELEASE MECHANISM.
Condition: Unknown
Due 20 March 2001
Resolved 23 March 2001
Lifesaving
Issued 19 March 2001 Resolved
REPLACE WORN RETROREFLECTIVE TAPE ON BOTH LIFEBOATS.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Fire Fighting
Issued 21 March 2000 Resolved
Vsl. must provide updated Fire Control Plan to include all portable fire extinguisher locations .
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 21 March 2000 Resolved
Vsl. must provide proof that old lifejackets meet SOLAS requirements for floatation.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 21 March 2000 Resolved
Vsl. must prove proper operation of port side embarkation lighting.
Condition: Unknown
Due 22 August 2000
Resolved 22 August 2000
Lifesaving
Issued 7 July 1998 Resolved
Hydraulic hose fittings for cargo hold hatch covers were leaking._x001C_ MARPOL ANNEX I _x001C_ _x001C_ *CORRECT PRIOR TO NEXT U.S. PORT*
Condition: Unknown
Due 23 September 1998
Resolved 23 September 1998
Lifesaving
Issued 22 January 1998 Resolved
A deficiency of SOLAS 74, Reg III/26.1 in that the starboard lifeboat did not start.
Condition: Unknown
Due 23 January 1998
Resolved 26 January 1998
Construction/Loadline
Issued 22 January 1998 Resolved
A deficiency of SOLAS 74, CH II, Reg. 2.21 in that the port general service/ballast pump was holed on the discharge side._x001C_ **To be corrected prior to returning to the U.S. after the next foreign voyage.**
Condition: Unknown
Due 26 April 1998
Resolved 26 April 1998
Lifesaving
Issued 13 August 1996 Resolved
PROVIDE OPERATIONAL LIFEBOAT MOTOR TO THE SATISFACTION OF THE CLASS SOCIETY
Condition: Unknown
Due 16 August 1996
Resolved 13 August 1996
Documentation
Issued 25 February 1987 Resolved
EACH OPERATION WAS NOT SIGNED BY PERSON IN CHARGE AS REQUIED BY 33 CFR 151.25(H)
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987
Navigation
Issued 25 February 1987 Resolved
CHARTS,COAST PILOT ADN LIGHT LIST NOT CURRENTLY CORRECTED AS REQUIRED BY 33 CFR 164.33
Condition: Unknown
Due 25 February 1987
Resolved 25 February 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.