MAURY USCG vessel records Sign in
← All vessels

SUN REEFER

SUN REEFER is a 1982 freight ship. The Coast Guard has recorded 15 inspections since 1986, most recently in February 1997, along with 49 deficiencies and 2 operational controls.

Records from 1986 to 1997. Most recent: operational control imposed, 3 February 1997.

Built
1982
Last inspected
3 February 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8204066 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227391
Flag
JAPAN
—
Maury page id
psix-227391

Inspections, by type

…with no type recorded15
Years with a record 7 calendar years (1986–1997)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1478 - Convention (Subpart B), Net Ton
3172 - Convention (Subpart B), Gross Ton
3804 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 15

3 February 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 400046
27 August 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 648998
19 August 1995 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 381881
20 January 1995 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 648676
9 January 1995 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 374165
27 April 1993 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 357842
7 December 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 648755
3 December 1992 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 354709
6 May 1992 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 648742
20 April 1992 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 648747
16 April 1992 Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 350208
17 March 1992 Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 111577
29 May 1990 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 337437
14 September 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 450127
14 August 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 310825

Deficiency record · 49

Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW THE ENGINE ROOM CONTROL SPACE A/C SALT WATER COOLING FLEXIBLE HOSE WITH METALLIC PIPING._x001C_ SOLAS 74 II-2/33(a)(viii)
Condition: Unknown
Due 10 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER COOLING PIPE FOR FRESH WATER GENERATOR IN BILGE IN WAY OF FRESH WATER COOLING PUMP FOR MAIN DIESEL ENGINE AND OUTBOARD OF #2 GENERATOR._x001C_ SEE SOLAS 74 (AMENDED)II-1/11(a)
Condition: Unknown
Due 10 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 3 February 1997 Resolved
Renew deteriorated/holed fire hoses on the 01 & 02 deck aft of the superstructure starboard side._x001C_ See SOLAS 74 (Amended) II-2/21_x001C_ _x001C_
Condition: Unknown
Due 9 February 1997
Resolved 10 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
Renew deteriorated/holed main deck fire hoses in way of the #1 & #2 deck houses._x001C_ See SOLAS 74 (Amended) II-2/21_x001C_ _x001C_
Condition: Unknown
Due 9 February 1997
Resolved 10 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
RENEW DETERIORATED/HOLED ACCOMMODATION SPACE FIRE HOSE AND REPAIR FIRE MAINSYSTEM TO PROVIDE FIRE MAIN PRESSURE TO ALL FIRE HYDRANTS WITHIN ACCOMMODATION SPACES._x001C_ SEE SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 10 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW/REPAIR DETERIORATED GOOSE NECK VENT LOCATED ON FORECASTLE STARBOARD SIDE._x001C_ SEE ILLC 66 ANNEX 1/19
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Unknown
Issued 3 February 1997 Resolved
COMPLETE OUTSTANDING CLASS ITEMS. SEE PSNS FOR CASE # PS97009970 FOR DETAILS.
Condition: Unknown
Due 1 July 1997
Resolved 21 March 1997
Fire Fighting
Issued 3 February 1997 Resolved
Renew as original the deteriorated fire main piping located in the #2 deck house in way of the lighting power panel._x001C_ See SOLAS 74 (Amended) II-2/21_x001C_ _x001C_
Condition: Unknown
Due 9 February 1997
Resolved 10 February 1997
Construction/Loadline
Issued 3 February 1997 Resolved
RENEW AS ORIGINAL THE DETERIORATED ANCHOR WASH PIPING STARBOARD SIDE IN FORECASTLE._x001C_ SEE SOLAS 74 (AMENDED) II-1/11(a)
Condition: Unknown
Due 9 February 1997
Resolved 10 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVE PROPER OPERATION OF ALL ENGINE ROOM FIRE HOSES IN THE PRESENTS OF THEATTENDING CG MARINE INSPECTOR._x001C_ SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 12 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE TO THIS OFFICE A PROPOSAL BY THE FLAG ADMINISTRATION ADEQUATE MEANSFOR THE PAINT LOCKER TO BE PROTECTED BY AN APPROPIATE FIRE EXTINGUISHING ARRANGEMENT._x001C_ SEE SOLAS 74 (AMENDED) II-2/18.7
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Construction/Loadline
Issued 3 February 1997 Resolved
RENEW/REPAIR DETERIORATED OVERHEAD/DECK IN GALLEY. THE 01 DECK HAS LARGE AMOUNTS OF CEMENT COVERING WASTED DECK WHICH HAS PENETRATED THE GALLEY SPACE._x001C_ SEE ILLC 66 ANNEX 1/25
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE TO COAST GUARD FLAG STATE REQUIREMENTS ON HYDROSTATIC TESTING ENTERVALS OF FIXED FIRE SUPPRESSION SYSTEM (CO2) FOR E/R._x001C_ SEE SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Lifesaving
Issued 3 February 1997 Resolved
REMOVE OIL AND OIL RESIDUE FROM ENGINE ROOM BILGES, E/R DECK IN WAY OF PURIFIERS (FUEL OIL), #1 & 2 DECK HOUSE DECKS AND IN STEERING ROOM SPACE._x001C_ SOLAS 74 AMENDED II-1/11(a)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW DETERIORATED CATWALK/WALKWAY DECKS AND FRAMES ON THE PORT SIDE OF VSLAND TOPSIDE OF FORECASTLE._x001C_ SEE ILLC 66 ANNEX 1/25
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW AS ORIGINAL DETERIORATED SEWAGE PIPING THROUGHOUT THE ENGINE ROOM IN WAY OF STARBOARD SIDE LUBE OIL SERVICE TANK FOR REFRIGERATOR UNIT AND IN WAY OF OILY WATER SEPERATOR._x001C_ SEE SOLAS 74 (AMENDED) II-1/11(a)
Condition: Unknown
Due 10 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW/REPAIR DETERIORATED OVERHEAD AND BULKHEAD IN E/R ADJACENT TO VSL'S HEADS._x001C_ SEE ILCC 66 ANNEX 1/25
Condition: Unknown
Due 19 February 1997
Resolved 13 February 1997
Engineering
Issued 3 February 1997 Resolved
RENEW/REPAIR DETERIORATED (OWS) OILY WATER SEPERATOR TANK AND PROVE PROPER OPERATION OF ENTIRE SYSTEM INCLUDING ALARMS._x001C_ SEE MARPOL 73/78 ANNEX 1/16(7)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW/REPAIR DETERIORATED REFRIGERATION CONDENSER END CAP TO #1 UNIT IN THESTEERING SPACE._x001C_ SEE SOLAS 74 (AMENDED) II-1/11(a)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Electrical
Issued 3 February 1997 Resolved
PROPERLY BLOCK/SECURE BATTERIES IN BATTERY LOCKER._x001C_ SEE SOLAS 74 II-1/27(A)(viii)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
RENEW THE DETERIORATED VENT COVER TO THE BATTERY LOCKER SPACE ON THE 02 DECK PORT SIDE._x001C_ SEE ILLC 66 ANNEX 1/19
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
RENEW THE DETERIORATED PORTABLE CO2 FIRE EXTINGUISHER NOZZLE LOCATED IN THEE/R IN WAY OF OWS._x001C_ SEE SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Electrical
Issued 3 February 1997 Resolved
PROPERLY MOUNT ELECTRICAL JUNCTION BOXES THROUGHOUT THE VESSEL. J BOXES ONTHE BRIDGE, BRIDGE LOOKOUT AND E/R WERE NOT MOUNTED._x001C_ SEE SOLAS 74 II-1/27
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Deck/Cargo
Issued 3 February 1997 Resolved
RENEW THE DETERIORATED #2 CARGO REFRIGERATION PUMP LOCATED IN THE E/R LOWERLEVEL._x001C_ SEE SOLAS 74 (AMENDED) II-1/11(A)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Documentation
Issued 3 February 1997 Resolved
PROVIDE ON BOARD FOR REVIEW, VALID (CERTIFICATES WITH VSL'S NAME) CLASSIFICATION CERTIFICATES.
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE ONBOARD FOR REVIEW, INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE._x001C_ SEE SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 10 February 1997
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE PROPER SIZE BOOTS FOR FIRE TEAM PERSONNEL/FIREMANS OUTFIT._x001C_ SEE SOLAS 74 (AMENDED) II-2/17
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE ONBOARD FOR REVIEW, AN UP TO DATE FIRE CONTROL PLAN._x001C_ SEE SOLAS 74 (AMENDED) II-2/20
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE THROUGHOUT ENGINE ROOM MOUNTING BRACKETS FOR ALL PORTABLE FIRE EXTINGUISHERS._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Engineering
Issued 3 February 1997 Resolved
POST A PERMANENT MUSTER LIST IN THE ENGINE CONTROL ROOM._x001C_ SOLAS 74 (AMENDED) III/8.3
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Fire Fighting
Issued 3 February 1997 Resolved
PROVIDE EVIDENCE THAT THE VESSEL'S PORTABLE CO2 FIRE EXTINGUISHERS HAVE BEEN HYDROSTATICALLY TESTED TO THE ADMINISTRATIONS STANDARDS._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Accommodation/Occupational Safety
Issued 3 February 1997 Resolved
REPAIR/RENEW DETERIORATED SECTION OF THE SEWAGE HOLDING TANK AFTER SECTION.SOLAS 74 I/11(a)
Condition: Unknown
Due 9 February 1997
Resolved 13 February 1997
Documentation
Issued 19 August 1995 Resolved
Manning not in accordance with minimum manning certificate; 1/E's license not endorsed for vessel's power (SOLAS 74, V/13; STCW 78).
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 19 August 1995 Resolved
Provide means acceptable to classification society to connect foam system required by SOLAS 74, II-2/7.1.2 to fire main.
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Documentation
Issued 19 August 1995 Resolved
Oil transfer procedures not complete, bunkering prohibited in U.S. waters until procedures which meet requirements of 33 CFR 155.750 are provided.
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 19 August 1995 Resolved
Fire equipment not stowed per fire control plan (SOLAS 74, II-2/20).
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Lifesaving
Issued 19 August 1995 Resolved
Two lifebuoys not permanently rigged for quick release; are fitted with self activating smokes (SOLAS 74, III/7.1.3).
Condition: Unknown
Due 22 August 1995
Resolved 22 August 1995
Fire Fighting
Issued 19 August 1995 Resolved
1 x 3 foot opening in bulkhead between air conditioning room and corridor does not meet the fire integrity requirements of SOLAS 74, II-2/44.
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Electrical
Issued 19 August 1995 Resolved
Space with emergency electircal switchboard used as storage locker; space must be kept clear.
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Fire Fighting
Issued 19 August 1995 Resolved
Doors to engine room are not self-closing as required by SOLAS 74, _x001C_ II-2/47.1. Doors are modified six dog watertight doors; door on starboard side is kept closed, door on port side is held back with a wooden door usedfor access to space from passageway.
Condition: Unknown
Due 7 February 1997
Resolved 7 February 1997
Lifesaving
Issued 19 August 1995 Resolved
Remove flammable gas bottles from steering gear room.
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Engineering
Issued 19 August 1995 Resolved
The oil water separator not operating properly; the sample drawn off while testing the unit had visible indications of oil, including a sheen (MARPOL 73/78, Annex I).
Condition: Unknown
Due 22 August 1995
Resolved 23 August 1995
Navigation
Issued 9 January 1995 Resolved
THE VESSEL SKYLARK WITH A GROSS TONNAGE OF 3,172; ENTERED PAGO PAGO HARBOR,AMERICAN SAMOA, WITHOUT A COAST PILOT PUBLICATION, COVERING THIS AREA.
Condition: Unknown
Due 27 August 1995
Resolved 27 August 1995
Documentation
Issued 9 January 1995 Resolved
THE VESSEL SKYLARK WHO COULD HOLD OVER 250 BARRELS OF FUEL OIL ENTERED PAGOPAGO HARBOR WITH IMCOMPLETE WRITTEN OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 27 August 1995
Resolved 27 August 1995
Navigation
Issued 3 December 1992 Resolved
Charts of the area not currently corrected.
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Navigation
Issued 3 December 1992 Resolved
Light list not currently corrected.
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Navigation
Issued 3 December 1992 Resolved
Coast pilot not currently corrected.
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Fire Fighting
Issued 16 April 1992 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Documentation
Issued 16 April 1992 Resolved
UPON CONDUCTING ANNUAL FRIEGHT VSL EXAM BOARDING OFFICERS NOTED VSL DID NOTHAVE ANY OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.