MAURY USCG vessel records Sign in
← All vessels

TROPIC MIST

TROPIC MIST is a 1983 freight ship. The Coast Guard has recorded 109 inspections since 1984, most recently in March 2026, along with 35 deficiencies and 9 operational controls.

Records from 1984 to 2026. Most recent: inspection, 9 March 2026.

Built
1983
Last inspected
9 March 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8204183 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227396
Flag
PANAMA
—
Maury page id
psix-227396

Inspections, by type

…with no type recorded62
Years with a record 39 calendar years (1984–2026)
The 109 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it1827 - Simplified, Gross Ton
1535 - Convention (Subpart B), Gross Ton
548 - Convention (Subpart B), Net Ton
2523 - Dead Weight, Ton
4200 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 109

9 March 2026 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8322836
25 August 2025 PSC B
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8215647
28 February 2025 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8085083
26 August 2024 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7985330
22 February 2024 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7868762
15 August 2023 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7768672
31 March 2023 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7660240
13 September 2022 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7553022
31 August 2022 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7547861
3 January 2022 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7374883
25 June 2021 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7186230
2 December 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7104821
17 November 2020 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7096747
13 October 2020 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 7064930
4 September 2020 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7067817
30 March 2020 PSC A
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6933566
24 September 2019 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6818470
29 March 2019 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6651804
16 October 2018 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6562110
23 April 2018 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6397428
2 November 2017 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6299525
9 May 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6141245
7 November 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6036597
23 June 2016 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5916205
23 May 2016 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5884527
8 December 2015 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5777323
23 November 2015 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 5768483
13 May 2014 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4856501
10 December 2011 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 4206429
23 November 2010 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3896513
11 September 2010 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 3847326
8 December 2009 ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex VI Survey · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3643861
5 May 2009 MARPOL Annex V Examination · PI Safety Exam · MARPOL Annex I Examination · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3467659
21 October 2008 MARPOL Annex V Examination · ISPS III Exam · PII Safety Exam · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3350694
3 October 2008 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3337238
24 June 2008 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 3250245
1 May 2008 Ballast Water Examination · PI Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3196279
10 October 2007 ISPS II Exam · PI Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3076932
19 June 2007 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2966689
18 June 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2965802
19 May 2007 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2934579
14 May 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2930248
24 April 2007 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2914436
23 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2913849
28 September 2006 MARPOL Annex I Examination · Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2789728
26 September 2006 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2787462
25 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2786728
14 September 2006 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2778125
13 September 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2777689
19 February 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2588060
28 January 2006 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2575107
27 January 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2574793
23 November 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2540225
13 May 2005 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2356560
15 April 2005 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2334630
12 March 2005 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 2308672
27 January 2005 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2281753
21 July 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2140359
23 June 2004 ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2107907
7 May 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2061828
23 March 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2029717
26 February 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2014233
11 October 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1926044
7 October 2003 Re-Inspection · Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1926083
24 March 2003 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1761834
29 October 2002 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1697840
8 October 2002 Periodic Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1687095
11 June 2002 Type not recorded
No type recorded · Station Lake Worth Inlet · USCG Southeast District (CGD-SE) · Activity 1629847
6 June 2002 Administrative Inspection
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1627162
20 April 2002 Re-Inspection · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 1604671
7 November 2001 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 648293
27 July 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 292644
7 July 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 179980
15 May 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 290073
1 February 2001 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3213453
1 February 2001 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 4093586
19 July 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 280141
17 December 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 435884
24 July 1999 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 431021
18 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 429877
18 June 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 430035
13 May 1999 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 428531
29 January 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 425082
26 October 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 538717
15 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 416965
27 May 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 416516
7 April 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 402422
31 March 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 402032
16 January 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 399704
20 November 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 398108
1 November 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 397198
22 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 509278
3 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 389974
23 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 387265
21 March 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 377551
16 February 1995 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 375580
11 January 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 374176
19 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 366937
22 July 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 359968
22 October 1992 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 357052
20 October 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347380
29 May 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 344139
23 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 337379
21 October 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 319216
28 January 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 314020
22 October 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 312232
14 December 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305999
26 March 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 463572
21 August 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 297561

Deficiency record · 35

02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 March 2026 Resolved
Electrical installations shall be such that the safety of passengers, crew and ship from electrical hazards will be ensured. During PSC B exam, PSCO discovered multiple wirinings exposed on lighting.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 March 2026
Resolved 9 March 2026
Resolution: Received report from Class, verifying deficiencies were rectified.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 March 2023 Resolved
The liferaft shall be so stowed as to be readily available in case of emergancy. It shall be stowed in such a manner as to permit it to float free from its stowage, inflate and break fre from the vessel in the event of sinking. Painter line on sole lliferaft onboard was tied directly to ship and not float free. 74 SOLAS III/15(p)(i)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 March 2023
Resolved 31 March 2023
Resolution: Corrected on spot
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 13 October 2020 Resolved
There shall be permanently exhibited in all existing ships for the guidance of the ships officers general arrangement plans showing clearly for each deck the control stations, the various fire sections enclosed by "A" class divisions and the sections enclosed by "B" class divisions. Current approved fire control plan onboard does not indicate "A" or "B" class divisions - 74 SOLAS II-2/Reg 4 - 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 November 2020
Resolved 2 December 2020
Resolution: Received class report consisting of new approved fire control plan (see attached documents). Def Cleared.
Communications › Visual Communication › Signalling Lamp
Issued 23 May 2016 Resolved
All ships shall be fitted with a daylight signalling lamp with an energy source of electrical power not solely dependent upon the ship's power supply. Signalling lamp currently does not have an independent means of power. 74SOLAS(09 CONS) V/19.2.2.2 50AC
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2016
Resolved 23 June 2016
Resolution: Vessel purchased independent source of power for Daylight Signaling lamp.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 November 2015 Resolved
Oil filtering equipment referred in paragraph 1 of this regulation shall be of a design approved by the administration and shall be such as will ensure that any oily mixture discharge into the sea after passing through the system has an oil content not exceeding 15ppm. Vessel's OWS unit was tested using samples but unit could not read sample past 8ppm.
Action required: 705 - Other - as specified
Due 7 December 2015
Resolved 8 December 2015
Resolution: Class BV report attested to proper working order.
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 23 November 2015 Resolved
The alarm shall operate both audible and visible signals at the main stations (bridge and control station). E/R fire alarm sounded but was not clearly audible.
Action required: 705 - Other - as specified
Due 7 December 2015
Resolved 8 December 2015
Resolution: Class report attested to proper working order.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 October 2008 Resolved
The OWS failed to operate properly. OWS oil content meter solenoid valve which regulates the flow of discharge to overboard or bilge retention piping is not operating properly. The flow of water continues to be directed overboard after the oil content meter alarms at levels above 15 ppm. Make proper repairs and test system in the presence of class surveyor prior to next operation of the OWS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 December 2008
Resolved 30 October 2008
Resolution: Coast Guard inspectors witnessed satisfactory shut down of sludge pump during 15 ppm test. Obtained class report dated 28 OCT 08 attesting to the satisfactory operation of OWS.
Electrical › Lighting (service) › Lighting Fixture
Issued 27 January 2005 Resolved
Repair loose wires for lights in paint locker. Replace light fixture or dead end wires in an approved junction box. Repair to the satisfaction issuing authority and provide report to U.S. Coast Guard prior to January 31, 2005, as per SOLAS 74 Amended II-I reg 40.
Due 31 January 2005
Resolved 15 April 2005
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 26 February 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 March 2004
Resolved 23 June 2004
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 26 February 2004 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Due 10 March 2004
Resolved 23 June 2004
Fire Fighting › Means of Escape
Issued 24 March 2003 Resolved
Provide and post hydraulic door instructions on both sides of doors. LEGACY COMPONENT DESC: Doorways
Action required: 705 - Other - as specified
Due 7 April 2003
Resolved 27 March 2003
Resolution: Cleared
Engineering › Diesel Engine (auxiliary)
Issued 24 March 2003 Resolved
Install protective guards around rotating machinery for all sewage pumps, ac pumps and salt water cooling pumps. LEGACY COMPONENT DESC: Crankshaft
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 May 2003
Resolved 27 March 2003
Resolution: Cleared
Engineering › Fuel Oil Storage/Transfer System
Issued 24 March 2003 Resolved
Install protective guards for hydraulic tank sight glasses. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 April 2003
Resolved 27 March 2003
Resolution: Cleared
Electrical › Lighting (emergency)
Issued 8 October 2002 Resolved
EMERGENCY LIGHTING NOT PROVIDED AT EMERGENCY ESCAPE STBD ENGINE ROOM. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 8 October 2002 Resolved
GUARD NOT PROVIDED FOR AROUND BOW THRUSTER ROTATING MACHINERY. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Electrical › Lighting (service)
Issued 8 October 2002 Resolved
LIGHTING FIXTURE AT STBD ENGINE ROOM ESCAPE NOT WIRED WITH APPROVED MARINE CABLE. LEGACY COMPONENT DESC: Lighting Fixture
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Documentation › Safety/Response Plans/Programs
Issued 8 October 2002 Resolved
FIRE SAFETY PLAN NOT APPROVED BY CLASS. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 8 October 2002 Resolved
OPERATING INSTRUCTIONS NOT POSTED FOR PAINT LOCKER FIXED FIREFIGHTING SYSTEM. LEGACY COMPONENT DESC: OPERATING INSTRUCTIONS
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Documentation › Manuals/Policy Documentation
Issued 8 October 2002 Resolved
STATION BILL DOES NOT REFLECT CORRECT MANNING. LEGACY COMPONENT DESC: Vessel Specific Watch Policy/Procedures
Action required: 705 - Other - as specified
Due 22 October 2002
Resolved 29 October 2002
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 8 October 2002 Resolved
ONE SCBA CYLINDER FOR FIREMANS OUTFIT EMPTY.
Action required: 17 - Rectify deficiencies prior to departure
Due 8 October 2002
Resolved 8 October 2002
Engineering › Compressed Air System (control)
Issued 20 April 2002 Resolved
Replace as orignal safety relief valve to the #1 control air unfired pressure vessel LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2002
Resolved 6 June 2002
Resolution: RECEIVED FAX FROM AGENT ABOUT CERTIFICATION OF TECHNICIAN AS OF TO REPAIR PERFORMED ON VALVE.
Lifesaving
Issued 18 June 1999 Resolved
PROVIDE NETTING FOR VESSEL STARBOARD SIDE GANGWAY.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Construction/Loadline
Issued 18 June 1999 Resolved
PROVIDE ALL REFERENCE MARKS FOR PORT AND STARBOARD SIDE LOADLINES.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Engineering
Issued 18 June 1999 Resolved
PROVIDE SUITABLE PIPING DIAGRAM FOR VESSEL FUEL/TANK SYSTEM AS PART OF THE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Fire Fighting
Issued 18 June 1999 Resolved
PROPERLY LABEL PAINT LOCKER SPRINKLER VALVE.
Condition: Unknown
Due 27 July 1999
Resolved 27 July 1999
Navigation
Issued 29 January 1999 Resolved
PROVIDE AT EMERGENCY STEERING CONNING POSITION DIRECTION FOR PORT/STBDSIDE.POST INSTRUCTION FOR EMERGENCY STEERING AT A PLACE READABLE/LEGIBLE TO OPERATOR.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Lifesaving
Issued 29 January 1999 Resolved
REPLACE 01 WATERLIGHT LOCATED AT PORT SIDE NEXT TO LIFEBOAT. CORRECT PRIOR TO 28FEB99.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Electrical
Issued 29 January 1999 Resolved
PROVIDE ELECTRICAL INSULATION MAT FOR AFT SECTION OF MAIN SWITCHBOARD LOCATED IN ENGINE ROOM. CORRECT PRIOR TO 28FEB99.
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Documentation
Issued 27 May 1998 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 May 1998
Resolved 29 May 1998
Documentation
Issued 27 May 1998 Resolved
PROVIDE CONSISTENT GROSS/NET TONNAGE ON BV ISSUED CERTIFICATES. ITC MUST REFLECT ACCEPTANCE OF NATIONAL TONNAGE IN REMARKS.
Condition: Unknown
Due 23 June 1998
Resolved 23 June 1998
Fire Fighting
Issued 1 November 1996 Resolved
PROVIDE SOLAS APPROVED FIRE HOSE NOZZLES.(CURRENT NOZZLES ARE PLASTIC)
Condition: Unknown
Due 16 March 1997
Resolved 1 April 1997
Construction/Loadline
Issued 1 November 1996 Resolved
OILY WATER SEPERATOR NOT OPERABLE.
Condition: Unknown
Due 20 November 1996
Resolved 29 November 1996
Fire Fighting
Issued 23 January 1996 Resolved
Service fixed co2 systems as per manufacturer recommendations; provide proof of service to USCG
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Accommodation/Occupational Safety
Issued 16 February 1995 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995
Engineering
Issued 11 January 1995 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPERATOR 15 PPM ALARM AND AUTOMATIC RECIRCULATION VALVE.
Condition: Unknown
Due 20 April 1995
Resolved 20 April 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.