MAURY USCG vessel records Sign in
← All vessels

RAVENNA

RAVENNA is a 1982 freight ship. The Coast Guard has recorded 20 inspections since 1987, most recently in July 2008, along with 10 deficiencies and 1 operational control.

Records from 1987 to 2008. Most recent: inspection, 14 July 2008.

Built
1982
Last inspected
14 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8204614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227401
Flag
PANAMA
—
Maury page id
psix-227401

Inspections, by type

…with no type recorded10
Years with a record 8 calendar years (1987–2008)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it3874 - Convention (Subpart B), Net Ton
7902 - Convention (Subpart B), Gross Ton
8824 - Dead Weight, Ton
13795 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 20

14 July 2008 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3261658
30 March 2006 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2612499
9 March 2006 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2597946
8 March 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2598882
17 November 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2536319
27 July 2005 Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2441746
27 July 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2441777
20 July 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2433733
19 May 2005 MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2362814
16 February 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2293732
3 August 2004 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2155147
11 March 2004 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2022908
23 January 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1991789
21 January 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1989167
22 January 2003 Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734029
7 July 1994 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 368319
22 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367950
22 June 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175178
17 March 1993 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 356957
5 June 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316571

Deficiency record · 10

Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 July 2008 Resolved
The vessel has not prepared or submitted a non-tank vessel response plan to the US Coast Guard in accordance with the US Federal water pollution control act as amended by section 701 and the coast guard maritime transportation act of 2004. the vessel must submit their non-tank vessel response plan to the Coast Guard.
Action required: 705 - Other - as specified
Resolved 15 July 2008
Resolution: Received fax from US COast Guard saying that the non-tank vessel response plan was submitted.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 9 March 2006 Resolved
Exhaust pipe for vessel's emergency fire pump is leaking excessively at the manifold. Violation of SOLAS 2004 Chapter II-1 Regulation 26, ILO 147. Rectify deficiency prior to next US port after sailing foreign to the satisfaction of the Coast Guard.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 9 April 2006
Resolved 30 March 2006
Resolution: observed the fire punp in good working order.
Navigation › Piloting/Steering › Gyro Compass
Issued 8 March 2006 Resolved
INOP Gyro
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 9 March 2006
Resolved 30 March 2006
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 November 2005 Resolved
Vessel's emergency fire pump was found to be leaking excessive amounts of oil. Vessel must fix leaks to the satisfaction of Class Society within (30) days. Cite SOLAS 74 unammended Ch. II-2 Reg. 33(a)(ii).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 December 2005
Resolved 7 March 2006
Resolution: Recieved class report attesting the repair of the emergency fire pump.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 17 November 2005 Resolved
Vessel's hospital wash space does not have running hot water. Vessel must provide hot running water in the hospital wash space to the satisfaction of Flag State within (30) days. Cite ILO 147.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 December 2005
Resolved 7 March 2006
Resolution: Recieved report noting the instalation of electric boiler.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 19 May 2005 Resolved
A fracture on the inbord and outboard sides of the starboard generator was noted during this inspection. The fractures are patched with putty and continue to leak oil and vapor. Fractures indicate the engine block is not mounted properly (level) on the engine bed. Provide class report accepting condition or repair prior to next U.S. port.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 July 2005
Resolution: Recieved class report attesting to repairs on starboard generator. All is satisfactory.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 January 2004 Resolved
VESSEL'S RUDDER ANGLE INDICATOR READINGS ON BRIDGE AND STEERING GEAR DID NOT CORRESPOND. INDICATORS WERE OFF 3 TO 5 DEGREES DURING STEERING TEST, A VIOLATION OF 33CFR164.25(a)(1)(iv). CORRECT PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 21 January 2004
Resolved 22 January 2004
Resolution: RECEIVED CLASS REPORT FROM BV ATTESTING TO SATISFACTORY REPAIR AND OPERATIONAL TESTING OF VESSEL''S STEERING GEAR. DEFICIENCY CLEARED.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 January 2004 Resolved
VESSEL'S BUNKER LINES WERE NOT CURRENTLY PRESSURE TESTED, A VIOLATION OF 33CFR156.170(a)(4) and 33CFR156.170(f)(3). CORRECT BEFORE ANY U.S. BUNKERING OPERATIONS.
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 21 January 2004
Resolved 21 January 2004
Resolution: RECEIVED STATEMENT FROM VESSEL''S MASTER AND [name withheld] TO A SATISFACTORY TEST OF BOTH BUNKER LINES TO A PRESSURE OF 8 BARS. DEFICIENCY CLEARED.
Engineering › Lubricating Oil Service System
Issued 21 January 2004 Resolved
OIL SOAKED PIPE LAGGING/INSULATION AROUND #3 GENERATOR IN ENGINE ROOM, A VIOLATION OF SOLAS 74/78 CH II-1 REG 26. CORRECT WITHIN 30 DAYS, PROVIDE CLASS REPORT. (NOTE: WAS ENDORSED AS A CONDITION OF CLASS TO CORRECT BY 20 FEB 04.) LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 February 2004
Resolved 11 March 2004
Resolution: RECEIVED FAX REPORT
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 January 2003 Resolved
The NO.2 generator had a cooling water leak on the NO.6 cylinder head.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 January 2003
Resolved 21 January 2004
Resolution: VERIFIED DEFICIENCY REPAIRED DURING AEF. DEFICIENCY CLEARED.

Ownership record