← All vessels
RAVENNA
Freight Ship · Refrigerated Cargo Ship class · Built 1980s · USCG Arctic District (CGD-A) · Other hulls named RAVENNA
RAVENNA is a 1982 freight ship. The Coast Guard has recorded 20 inspections since 1987, most recently in July 2008, along with 10 deficiencies and 1 operational control.
Records from 1987 to 2008. Most recent: inspection, 14 July 2008.
- Built
- 1982
- Last inspected
- 14 July 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 10 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8204614 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EGY
227401
Flag
PANAMA
—
Maury page id
psix-227401
Inspections, by type
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.
Documentation record
Tonnage as PSIX records it3874 - Convention (Subpart B), Net Ton
7902 - Convention (Subpart B), Gross Ton
8824 - Dead Weight, Ton
13795 - Displacement, Ton
7902 - Convention (Subpart B), Gross Ton
8824 - Dead Weight, Ton
13795 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
14 July 2008
Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 3261658
30 March 2006
Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2612499
9 March 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2597946
8 March 2006
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2598882
17 November 2005
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2536319
27 July 2005
Random ISPS/MTSA/PSC
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2441746
27 July 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2441777
20 July 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2433733
19 May 2005
MARPOL Annex I Examination · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2362814
16 February 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2293732
3 August 2004
ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2155147
11 March 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2022908
23 January 2004
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1991789
21 January 2004
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1989167
22 January 2003
Annual Inspection · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1734029
7 July 1994
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 368319
22 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 367950
22 June 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1175178
17 March 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 356957
5 June 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 316571
Deficiency record · 10
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 14 July 2008
Resolved
The vessel has not prepared or submitted a non-tank vessel response plan to the US Coast Guard in accordance with the US Federal water pollution control act as amended by section 701 and the coast guard maritime transportation act of 2004.
the vessel must submit their non-tank vessel response plan to the Coast Guard.
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 9 March 2006
Resolved
Exhaust pipe for vessel's emergency fire pump is leaking excessively at the manifold. Violation of SOLAS 2004 Chapter II-1 Regulation 26, ILO 147. Rectify deficiency prior to next US port after sailing foreign to the satisfaction of the Coast Guard.
Navigation › Piloting/Steering › Gyro Compass
Issued 8 March 2006
Resolved
INOP Gyro
Fire Fighting › Emergency Fire Pumps › Arrangement
Issued 17 November 2005
Resolved
Vessel's emergency fire pump was found to be leaking excessive amounts of oil. Vessel must fix leaks to the satisfaction of Class Society within (30) days. Cite SOLAS 74 unammended Ch. II-2 Reg. 33(a)(ii).
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 17 November 2005
Resolved
Vessel's hospital wash space does not have running hot water. Vessel must provide hot running water in the hospital wash space to the satisfaction of Flag State within (30) days. Cite ILO 147.
Engineering › Gasoline Engine (propulsion) › Engine Block (4 cycle)
Issued 19 May 2005
Resolved
A fracture on the inbord and outboard sides of the starboard generator was noted during this inspection. The fractures are patched with putty and continue to leak oil and vapor. Fractures indicate the engine block is not mounted properly (level) on the engine bed. Provide class report accepting condition or repair prior to next U.S. port.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 21 January 2004
Resolved
VESSEL'S RUDDER ANGLE INDICATOR READINGS ON BRIDGE AND STEERING GEAR DID NOT CORRESPOND. INDICATORS WERE OFF 3 TO 5 DEGREES DURING STEERING TEST, A VIOLATION OF 33CFR164.25(a)(1)(iv). CORRECT PRIOR TO DEPARTURE TO SATISFACTION OF CLASS.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 January 2004
Resolved
VESSEL'S BUNKER LINES WERE NOT CURRENTLY PRESSURE TESTED, A VIOLATION OF 33CFR156.170(a)(4) and 33CFR156.170(f)(3). CORRECT BEFORE ANY U.S. BUNKERING OPERATIONS.
Engineering › Lubricating Oil Service System
Issued 21 January 2004
Resolved
OIL SOAKED PIPE LAGGING/INSULATION AROUND #3 GENERATOR IN ENGINE ROOM, A VIOLATION OF SOLAS 74/78 CH II-1 REG 26. CORRECT WITHIN 30 DAYS, PROVIDE CLASS REPORT. (NOTE: WAS ENDORSED AS A CONDITION OF CLASS TO CORRECT BY 20 FEB 04.) LEGACY COMPONENT DESC: Piping
Engineering › Generator (propulsion/auxiliary-electric)
Issued 22 January 2003
Resolved
The NO.2 generator had a cooling water leak on the NO.6 cylinder head.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National