MAURY USCG vessel records Sign in
← All vessels

LIVADIA

LIVADIA is a 1983 freight ship. The Coast Guard has recorded 21 inspections since 1984, most recently in September 2010, along with 17 deficiencies — 2 with no resolution recorded —.

Records from 1984 to 2010. Most recent: inspection, 7 September 2010.

Built
1983
Last inspected
7 September 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8209078 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227415
Flag
SLOVAKIA
—
Maury page id
psix-227415

Inspections, by type

…with no type recorded17
…past their stated due date1
Years with a record 16 calendar years (1984–2010)
The 21 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it2699 - Regulatory (Subpart C or D), Net Ton
6127 - Regulatory (Subpart C or D), Gross Ton
6127 - Convention (Subpart B), Gross Ton
6324 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 21

7 September 2010 Ballast Water Examination · ISPS II Exam · Deficiency Check · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3840189
10 May 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353720
21 April 2005 ISPS III Exam · Random ISPS/MTSA/PSC
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2339496
20 April 2005 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2340429
18 April 2005 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2336673
27 June 2004 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2110366
11 July 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 291692
3 April 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 426998
5 January 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 411336
21 March 1996 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 388996
10 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 479944
5 June 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 523390
19 February 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341924
14 January 1990 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 334761
21 January 1989 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 328030
5 August 1987 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 317718
26 February 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307271
6 November 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 536335
11 April 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 301334
5 February 1985 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 300213
22 October 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 533310

Deficiency record · 17

Fire Fighting › Fire Hoses › Condition
Issued 7 September 2010 Resolved
Fire Fighting systems and appliances shall be kept in good working order and readily available for immediate use. 7 of 17 Fire Hoses were found wasted. Sprinkler system in Paint Locker was found with a soft patch and clogged nozzles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2010
Resolution: Class survey complete and confirmed temporary repairs.
Fire Fighting › Fire Hydrants › Location/Position
Issued 7 September 2010 Resolved
Fire Control Plan shall be developed outlining required general arrangements and firefighting equipment. Review of Fire Control Plan showed numerous missing fire station hose boxes, extinguishers, and lifesaving appliances.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2010
Resolution: Class Survey Attested to the repairs.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 7 September 2010 Resolved
Solas 74 (09) CH. III Reg 20. Before the ship leaves port and at all times during the voyage all Life Saving Appliances shall be in working order and ready for immediate use. STBD Lifeboat was unable to start initially due to water in fuel, Hull had delamination, and wastage of grab rail was observed on Port Lifeboat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2010
Resolution: Class Survey attested to the repairs.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 September 2010 Resolved
Solas 74 CH II-2 Reg 9. Doors installed in Class "A" boundaries shall provide resistance to fire as well as smoke passage equivalent to that of the bulkhead in which they are situated. Class "A" Door from provision room/reefer flat was missing. Bulkhead penetration was also improper.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2010
Resolution: Class Survey attested to the repairs.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 7 September 2010 Resolved
Solas 74 (09) CH II-2 Reg 9.4.2.2. Doors required to be self closing shall not be fitted with holdback hooks. Class "A" Fire door to steering gear flat was observed with holdbacks installed and in use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 September 2010
Resolution: Class Survey attested to the repairs.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 7 September 2010 Resolved
Vessel shall be provided with mechanical plugs for all bunkering fuel ventilation stations. Plugs were not provided for all fuel bunkering and ventilation stations.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 September 2010
Resolution: Class Survey attested to the repairs.
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 September 2010 No resolution recorded
Vessel shall be maintained in accordance with relevant certificates. Numerous soft patches were identified on main engine cooling water piping. Explosion lighting in paint locker is improperly installed, and life jacket donning placards were not in accordance with the onboard life jackets.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 7 September 2010 No resolution recorded
0630-Lifesaving-One or more liferafts capable of being launched on either side of the ship and such aggragate capacity as will accomodate the total number of persons onboard shall be provided. Vessel is provided with two 16 person liferafts that must be transferred across deck. Provide transfer arrangements or ensure total capacity of crew compliment in liferaft.SOLAS 74 Ch.III/31.3.1(50a/c)
Action required: 705 - Other - as specified
Due 13 October 2010 — due date passed with no resolution recorded
Lifesaving
Issued 11 July 2001 Resolved
Class society to address port & stbd lifeboat's tracing pendants, which restrict proper operation.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Lifesaving
Issued 11 July 2001 Resolved
Class society to attest to temporary repairs on discharge line for air compressor cooler.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Construction/Loadline
Issued 11 July 2001 Resolved
Class society to address the doubler fitted to the hull iwo #4 cargo hold aft stbd side above the water line.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Lifesaving
Issued 11 July 2001 Resolved
Port lifeboat chain plate which secures eyebolt associated with forward painter found in wasted condition. Vessel's class society to recommend repairs.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Accommodation/Occupational Safety
Issued 11 July 2001 Resolved
Class society to attest to temporary repairs on MSD tank.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Electrical
Issued 11 July 2001 Resolved
#2 auxiliary diesel generator cooling water supply lineto be repaired to the satisfaction of class. (soft patch before valve)_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Engineering
Issued 11 July 2001 Resolved
Class society surveyor to attest to proper operation of force draft fan. Inoperable.
Condition: Unknown
Due 11 July 2001
Resolved 17 July 2001
Lifesaving
Issued 3 April 1999 Resolved
RING BUOY WATERLIGHT INOPERATIVE. CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 April 1999
Resolved 3 April 1999
Navigation
Issued 5 February 1985 Resolved
NOS CHARTS;18720, 18740, 18746, 18751 OUTDATED EDITIONS. USCG LIGHT LIST VOL III NOB. NOS COAST PILOT VOL 7 OUTDATED.
Condition: Unknown
Due 5 February 1985
Resolved 5 February 1985

Ownership record