MAURY USCG vessel records Sign in
← All vessels

KOSTAS N

KOSTAS N is a 1982 freight ship. The Coast Guard has recorded 52 inspections since 1985, most recently in August 2011, along with 43 deficiencies and 9 operational controls.

Records from 1985 to 2011. Most recent: inspection, 18 August 2011.

Built
1982
Last inspected
18 August 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8210077 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B3915
227420
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-227420

Inspections, by type

…with no type recorded37
Years with a record 22 calendar years (1985–2011)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it13299 - Regulatory (Subpart C or D), Net Ton
22258 - Regulatory (Subpart C or D), Gross Ton
35971 - Dead Weight, Ton
45153 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

18 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4120839
10 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4111878
10 August 2011 MARPOL Annex I Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4112002
10 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4113806
3 August 2011 PII Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4102274
3 August 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4104320
29 July 2011 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4098722
11 February 2010 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3678693
16 October 2008 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3346144
14 October 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3344641
24 July 2008 ISPS I Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3277448
24 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3277661
21 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3274883
27 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3137455
27 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3137791
26 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3135882
21 November 2007 Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3102206
1 October 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam · MARPOL Annex I Examination · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3062871
28 September 2007 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3064902
29 June 2006 PII Safety Exam · ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2694952
29 June 2006 Type not recorded
No type recorded · Maritime Safety & Security Team New York (91106) · Activity 2695175
15 June 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2680887
12 April 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2623528
17 June 2005 ISPS III Exam · PII Safety Exam
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2393208
20 October 2004 PII Safety Exam
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 2224651
14 July 2004 ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2132843
22 January 2004 MARPOL Annex I Examination · Annual Inspection · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1990484
29 December 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1970765
28 December 2003 Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1970204
16 December 2003 Re-Inspection
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1964950
16 February 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745281
24 January 2003 Passenger/Freight Vessel Examination · Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1734201
4 September 2001 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 293513
27 August 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 293162
31 January 2000 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 274129
27 December 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 274370
27 December 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 436169
20 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428821
7 October 1998 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 421215
8 September 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 407399
14 June 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 404642
6 July 1994 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 368634
25 January 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 528159
28 January 1991 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 341552
12 January 1990 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 334717
10 February 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 437443
29 June 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324220
11 March 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 314708
14 December 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 313465
26 March 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 490053
17 July 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 303137
9 January 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 507722

Deficiency record · 43

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 10 August 2011 Resolved
1730; Oil samples were taken from various pipes in the E/R, including the boiler blow down overboard valve, which leads us to believe the oily water separator has been bypassed. Examination of the system including the oil content meter must be made by a technical representative and Class, 30.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 27 January 2012
Resolution: Case closed. Recieved clas report Aug 14, 2011. Vesselhas made allapplicable corrections.
Engineering › Shafting/Propeller Arrangements › Stern Tube
Issued 10 August 2011 Resolved
1400; Sea water has entered the stern tube lube oil sump tank causing contamination of the system. Class must inspect and verify proper operation, 17.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 13 August 2011
Resolution: System was tested and no leakage was observed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 10 August 2011 Resolved
1100; Bulk carriers of 150m in length and upwards shall be fitted with a loading instrument capable of providing information on hull girder shear forces and bending moments, taking into account recommendations adopted by the organization. The ship's loading computer has failed and Captain is using personnel laptop for calculations, Class must address, 17.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 13 August 2011
Resolution: Ship''s computer had a problem. Captain put it on his laptop as a temporarily measure. Information from previous computer is now loaded onto another computer and is okay according to Class. A new computer for the loading program will be installed ASAP.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 10 August 2011 Resolved
0330; Modifications of bilge holding tank has been made for the collection of sewage and Class must inspect, 17.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 13 August 2011
Resolution: Condition of Class issued; Temporary connections are to be removed and piping systems and tanks are to be restored as original.
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 August 2011 Resolved
1400; A salt water line leading from the main pipe on the starboard side of the engine room has been added by the crew. This line connects to the boiler blow down piping located in the aft port side of the engine room, Class must address, 17, A/B.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 13 August 2011
Resolution: Line is for the cooling of the intermediate shaft bearings.
Documentation › Certificates/Documents › IOPP Certificate
Issued 10 August 2011 Resolved
0105; IOPP certificate sections 3.3 states that the volume for bilge water holding tank is 71.31m3. Capacity plan and trim correction table states capacity is 63.28m3, Class must address, 17, A/B/C.
Action required: 17 - Rectify deficiencies prior to departure
Due 12 August 2011
Resolved 13 August 2011
Resolution: Corrected to the satisfaction of Class, an additional tank was converted as a bilge holding tank and the capacity was later added making the total on the IOPP certificate correct.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 August 2011 Resolved
1730: OWS has been renewed, however old system is still in place with blank flanges for unknown use. USCG sealed with #00550,00539,00532. Classification society must inspect and verify usage of blank flanges. Class is authorized to remove seals and report findings to USCG Sector San Francisco. - MARPOL I/14 ; 17a/b/c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 10 August 2011
Resolution: Class rep examined OWS and piping system, all found to be in order, class report issued, this deficiency cleared. However, information gathered during this process led to an expanded MARPOL exam and the issuance of further deficiencies. See narrative.
Lifesaving › Launching Appliances › Davit
Issued 3 August 2011 Resolved
0613: Forward inboard sheave on port lifeboat failed to operate properly. - SOLAS (83) III/19 ; 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 10 August 2011
Resolution: Sheave was replaced and the lifeboat was lowered in the presence of USCG and class representative. Class report issued, deficiency cleared.
Fire Fighting › Fire Main › Condition
Issued 3 August 2011 Resolved
0720: Fire main needs to be pressure tested for integrity. Report findings to USCG sector San Francisco. - SOLAS (83) II-2/4 ; 17 c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 5 August 2011
Resolution: Received a report from the vessel superintendant attesting to the satisfactory testing of the fire main at 5 bars.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 3 August 2011 Resolved
2035: Accommodation spaces have been turned into storage spaces. This must be reflected in the fire control plan. Several doors are missing locking devices which are designed as A-0 boundaries. Glass in galley is broken which will allow air to support a potential fire. - SOLAS (83) II-2/20 ; 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 10 August 2011
Resolution: Fire control plans were updated to include changes to vessel layout, glass in galley replaced, and door locks were installed. Class report issued, deficiency cleared.
Engineering › Steam System (main) › Piping
Issued 3 August 2011 Resolved
1410: Steam heating lines to HFO tanks in engine room have concrete patches. M/E salt water discharge cooling line to air cooler has leak. Incinerator sight glass is missing. M/E leakage of MGO. Class must address. - SOLAS (83) II-1/26 ; 17a/c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 10 August 2011
Resolution: Condition of class issued for steam heating lines, leaking salt water line pipe section was replaced, incinerator sight glass opening was covered, and M/E leakage was cleaned up. Class report issued, deficiencies cleared.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 3 August 2011 Resolved
0950: Electrical problems exist throughout ship. Examples: 1) various grounds 2) cable passes 3) temperature sensors on M/E. Crew must go throughout vessel to address these issues. - SOLAS (83) II-1/45 ; 70a/b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 August 2011
Resolved 10 August 2011
Resolution: Attended vessel with class representative; cable passes were sealed, M/E temperature sensors were replaced, and no electrical grounding issues were found. Class issued report, deficiency cleared.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 3 August 2011 Resolved
2055: SOLAS training manual must include ship specific items. Training manuals do not include ship specific items. - SOLAS (83) III/51 ; 70a/b
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 August 2011
Resolved 10 August 2011
Resolution: SOLAS training manuals were updated to include vessel specific items and information.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 3 August 2011 Resolved
1550: STBD navigation light lens is cracked. Port navigation light lamp was not properly secured. ARPA collision alarm was not engaged. Ensure lights are corrected and training for ARPA conducted. - 33CFR84.15 ; 17c
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2011
Resolved 10 August 2011
Resolution: Navigation lights were repaired/replaced, and ARPA training was conducted for all Deck Officers.
Fire Fighting › Firemans Outfit › Gloves
Issued 24 July 2008 Resolved
Firefighting gloves protective outside shell worn off
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 July 2008
Resolution: Master called MSD Lewes to say firefighting gloves were purchased.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 24 July 2008 Resolved
Entry port on Incinerator is cracked at the base connecting both loading tube and main incinerator. Repairs from past maintenance have failed to keep incinerator sealed.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 16 October 2008
Resolution: Received class report from Lloyd''s Register satisfying requirement.
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 24 July 2008 Resolved
Emergency fire pump unable to take suction and pressurize firemain due to current draft.
Action required: 705 - Other - as specified
Resolved 24 July 2008
Resolution: Emergency Fire pump working properly. Ballast was shifted aft to get a deeper draft for pump to take suction
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 27 January 2008 Resolved
The notice of arrival provided by the Master of SPAR TWO listed crewmember PAWAN KUMAR SINGH's passport number as E8840723. A review by Sector Jacksonville boarding team determined that the actual passport number was E8440723; therefore, the SPAR TWO violated 33CFR160.206.
Due 27 January 2008
Resolved 27 January 2008
Resolution: Boarding team verified the passport information through local CBP. After determining there was no security threat to the port, the boarding team allowed the vessel in port with the understanding that the notice of arrival would be corrected.
Navigation › Piloting/Steering › Gyro Compass
Issued 21 November 2007 Resolved
Vessel experienced operational failure of gyrocompass during outbound transit from Provport in Providence, RI. Vessel must have an FCC licensed technician or Class Society surveyor attend to ensure repairs have been effected and proper operation of gyrocompass can be demonstrated.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2007
Resolved 22 November 2007
Resolution: Received satisfactory report from FCC licensed technician. Technician replaced sphere and conducted annual servicing. Tests sat.
Lifesaving › Lifebuoys
Issued 22 January 2004 Resolved
VLS TO REPLACE ONE INOPERATIVE BUOY LIGHT. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Resolution: DEFICIENCY CORRECTED DURING EXAM.
Fire Fighting › Combustible Materials
Issued 22 January 2004 Resolved
VSL TO REMOVE PAINT CANS FROM ABOVE SPRINKLER SYSTEM IN PAINT LOCKER. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Resolution: DEFICIENCY CORRECTED DURING EXAM.
Fire Fighting › Fire Hoses
Issued 22 January 2004 Resolved
VSL TO REPLACE ONE FIRE HOSE. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 22 January 2004
Resolved 22 January 2004
Resolution: DEFICIENCY CORRECTED DURING EXAM.
Navigation › Collision/Grounding Avoidance
Issued 16 February 2003 Resolved
Inoperable primary radar (33 CFR 164.37[a]): Repair radar and provide servicing report to [name withheld]: Radar
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2003
Resolution: Rec''d tech rpt from [name withheld] attesting to sat repair & test.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 24 January 2003 Resolved
Replace missing bulbs and repair emergency lighting fixtures near lifeboat embarkation areas.
Due 24 January 2003
Resolved 24 January 2003
Resolution: Corrected prior to departure.
Fire Fighting › Emergency Fire Pumps
Issued 24 January 2003 Resolved
Replace broken valve handle on air cylinder for emergency fire pump. Prove proper operation of emergency fire pump.
Condition: Improper/Lack of Maintenance
Due 24 January 2003
Resolved 24 January 2003
Resolution: Corrected prior to departure.
Lifesaving
Issued 27 August 2001 Resolved
Remove all meal ration pack that lost there vacuum seal from lifeboats. Corrected on-the-spot.
Condition: Unknown
Due 27 August 2001
Resolved 28 August 2001
Lifesaving
Issued 27 August 2001 Resolved
Provide new retro tape on lifeboat prior to 04SEP01.
Condition: Unknown
Due 4 September 2001
Resolved 4 September 2001
Fire Fighting
Issued 27 December 1999 Resolved
PROPER FIREMANS BOOTS, SOLAS 74/AM III53.5.2
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Fire Fighting
Issued 14 June 1997 Resolved
vessel's suba had inoperable regulator.
Condition: Unknown
Due 15 June 1997
Resolved 19 June 1997
Fire Fighting
Issued 14 June 1997 Resolved
ONE OF THE VESSELS SCBA MASK IS MISSING AN EXHALATION VALVE RENDERING IT INOPERABLE.
Condition: Unknown
Due 15 June 1997
Resolved 17 June 1997
Navigation
Issued 29 June 1988 Resolved
VESSEL'S LORAN-C UNIT DID NOT HAVE THE REQUIRED LABEL.
Condition: Unknown
Due 16 September 1997
Resolved 16 September 1997
Navigation
Issued 29 June 1988 Resolved
VESSEL'S CHART 18521 HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL'S CHART 18523 HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL DID NOT HAVE ONBOARD A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL DID NOT HAVE ONBOARD A CURRENT COPY OF THE TIDE TABLES.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL DID NOT HAVE ONBOARD A CURRENT COPY OF THE TIDAL CURRENT TABLES.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL;S CHART 18524 HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL'S CHART 18526 HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL'S COAST PILOT HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 29 June 1988 Resolved
VESSEL'S LIGHT LIST HAD NO CORRECTIONS.
Condition: Unknown
Due 2 July 1988
Resolved 29 June 1988
Navigation
Issued 14 December 1986 Resolved
VESSELS US COAST PILOT #7 AND CG LIGHT LIST VOL III NOT CURRENTLY CORECTED AS PER 33 CFR 164.33(A)(2)(I)AND (II)
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Engineering
Issued 14 December 1986 Resolved
DURRING OPERATIONAL TEST OF 15PPM SEPERATOR, ALARM FAILED TO WORK, SEPERATOR DID FUNCTION PROPERLY EXCEPT FOR ALARM.
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986
Documentation
Issued 14 December 1986 Resolved
VESSEL REQUIRES CARGO INFORMATON CARDS AS PER 33 CFR 155.750(A)(1)(I)(II)
Condition: Unknown
Due 14 December 1986
Resolved 14 December 1986

Ownership record