Records from 1985 to 2012. Most recent: inspection, 7 June 2012.
Inspection history · 58
7 June 2012
Ballast Water Examination · PII Safety Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4336100
7 June 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4336678
6 June 2012
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4336091
3 December 2011
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4196744
22 August 2011
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4123950
20 August 2011
STCW 95 Exam
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 4123941
17 December 2008
Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3381401
17 November 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3364651
22 September 2008
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3330942
19 June 2008
NPV Safety Exam · Deficiency Check · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3241711
24 December 2007
PII Safety Exam · ISPS III Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3116801
15 June 2007
ISPS II Exam · PII Safety Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2962745
18 January 2007
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2857057
19 September 2006
Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2781860
18 September 2006
Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2781445
2 June 2006
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2668410
16 May 2006
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2650854
7 September 2005
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2487304
16 May 2005
ILO-147 Exam · Administrative Inspection · PII Safety Exam · ISPS II Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2359394
16 May 2005
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2359576
24 November 2004
Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2247312
16 August 2004
ILO-147 Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · STCW 95 Exam · PII Safety Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2167331
11 July 2004
ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2128933
7 March 2004
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2019902
10 February 2004
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2003550
8 February 2004
Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1998350
6 November 2003
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1943269
31 October 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1940378
25 August 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1886321
18 February 2003
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1745946
27 January 2003
Annual Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1730705
2 May 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1611749
24 April 2002
In-Service Inspection · Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1608973
27 March 2002
Ballast Water Examination · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1598067
29 January 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1482325
28 September 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 294153
29 March 2001
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288497
28 April 2000
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 277243
31 January 2000
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 274232
21 November 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 434974
7 October 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 433525
7 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 177182
7 November 1998
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 422407
3 June 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 391721
31 May 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 391714
20 October 1995
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 383898
6 October 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 383450
19 July 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 380781
18 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 361861
5 June 1992
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 351173
4 October 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 468471
28 April 1989
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 330026
6 June 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 501454
27 November 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 319863
1 December 1986
Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 313017
11 July 1986
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 310089
9 January 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 472583
25 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 303335
Fire Fighting › Fire Main › Condition
Issued 20 November 2008
Resolved
Fire main in way of centerline topside deck between cargo ramps leaking due to excessive corrosion, although adequate pressure demonstrated.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2008
Resolution: Received satisfactory class report attesting to satisfactory repairs made to the fire main.
Deck/Cargo › Holds/Tanks › Coaming
Issued 20 November 2008
Resolved
Hydraulic piping on port side above cargo ramp experienced failure. Temp repairs were made and tested SAT. Make permanent repairs.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2008
Resolution: Received class report attesting to the replacement of damaged piping with new piping.
Engineering › Generator (propulsion-electric) › Wiring
Issued 17 November 2008
Resolved
Containment around vacuum pump for starboard steam generator and cascade tank for same wasted, allowing water to drip onto electrical installations.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2008
Resolution: Received Class Survey attesting to satisfactory repairs of the containment area around the vacuum pump for the the starboard steam generator and cascade tank.
Fire Fighting › Fire Hoses › Condition
Issued 17 November 2008
Resolved
02 fire hoses wasted, no replacements. SOLAS74/II-2/5(f).
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 November 2008
Resolution: Vessel was delivered 02 new fire hose to meet requirements
Lifesaving › Lifeboat › Canopy
Issued 10 September 2008
Resolved
The Port side lifeboat's canopy is torn creating a two foot by one foot hole. SOLAS 74 CH III Reg 11 (a) (xxvi)
Rectify to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: Canopy was renewed.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2008
Resolved
The stanchion holders in the lifeboat have all rusted and broken off of the portside lifeboat. There is no way to secure the stanchions to the lifeboat to stabilize the canopy. SOLAS 74 CH III Reg 4 (a)
Rectify to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: New stanchions were affixed to the lifeboat.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2008
Resolved
The stanchions on the port side lifeboat that support the canopy have rusted completely through and are broken at the joints. (8 totoal) SOLAS 74 Ch. III Reg. 4 (a)
Rectify to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: Stanchions were renewed.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2008
Resolved
Two stanchion holders in the starboard lifeboat have rusted and broken off. There is no means of securing the stanchions to the lifeboat to stabalize the canopy. SOLAS 74 CH III Reg 4 (a)
Rectify to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: Stanchions were renewed.
Lifesaving › Lifeboat › Seating
Issued 10 September 2008
Resolved
The aft seat in the starboard lifeboat was found completely rotted through and seperated from the lifeboat. The wood was dry rotted next to the securing bolts. SOLAS 74 Ch III Reg 4 (c)
Rectify to the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2008
Resolution: The aft seat was removed from the lifeboat and a new seat was fabricated along with new bolts for securing.
Lifesaving › Lifeboat › Seating
Issued 10 September 2008
Resolved
The seat where the fuel tank is attached on the starboard lifeboat is cracked and dry rotted next to the securing bolt. SOLAS 74 Ch III Reg 4 (a) Rectify to the sat of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2008
Resolution: The crew fabricated a new seat and attached it securely to the lifeboat with the fuel tank underneath as intended.
Lifesaving › Lifeboat › Canopy
Issued 10 September 2008
Resolved
All of the stanchions used for the canopy on the starboard side lifeboat have rusted completely through. One stanchion was so rusted it was found in three seperate pieces. SOLAS 74 Ch III Reg 4 (a)
Rectify to the sat of Class.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: Stanchions were renewed.
Lifesaving › Lifeboat › Propulsion Starting System
Issued 10 September 2008
Resolved
The battery connection to the starboard lifeboat engine is broken in half and hanging by two wires. If the lifeboat was placed in the water, the movement would disconnect the battery. SOLAS 74 Ch III Reg 9 (a) (i)
Rectify to the sat of the Coast Guard.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2008
Resolution: The electrician reassembled the battery wire to the engine with new wires and connections.
Lifesaving › Lifeboat › Propulsion Casing/Protection
Issued 10 September 2008
Resolved
The battery box casing on the starboard side lifeboat is rusted through allowing outside elements to enter through the rust holes to the battery. SOLAS 74 Ch III Reg 9 (a) (ii)
Rectify to the sat of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2008
Resolution: The crew fabricated a new weathertight metal box to support the battery for the engine in the starboard lifeboat.
Lifesaving › Lifeboat Equipment › Boat Hook
Issued 10 September 2008
Resolved
One boat hook on the starboard side lifeboat is cracked half way down from the top and dry rotting from the inside out. SOLAS 74 Ch III Reg 11 (c)
Rectify to the sat of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2008
Resolution: Vessel was provided with a new boat hook for the starboard lifeboat.
Deck/Cargo › Holds/Tanks › Coaming
Issued 24 December 2007
Resolved
Hydraulic piping from accumulator to center ram on weather deck leaks excessively. Leak may impair performance of ramp.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 November 2008
Resolution: Piping was renewed and verified to be leak free.
Communications › Radio Communications › EPIRB
Issued 15 June 2007
Resolved
EPIRB Battery Expired
Action required: 17 - Rectify deficiencies prior to departure
Due 15 June 2007
Resolved 15 June 2007
Resolution: ACR electronics technician attended vessel, replaced EPIRB battery and submitted report to this office.
Navigation › Collision/Grounding Avoidance › Radar
Issued 18 September 2006
Resolved
Inoperable secondary marine radar.
Action required: 17 - Rectify deficiencies prior to departure
Due 18 September 2006
Resolved 18 September 2006
Resolution: received tech report of repairs conducted operational test of radar.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 16 May 2006
Resolved
Fire Control Plan does not indicate any class "A" divisions. To the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 May 2006
Resolved 29 May 2006
Resolution: Recieved Class report attesting to Class "A" Divisions being placed on Fire Control Plan.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 16 May 2006
Resolved
Steel door to space #145 A/C room is not gas tight as indicated on Fire Control Plan. Door framing is warped at both top & bottom right corners. To the satisfaction of class.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 16 May 2006
Resolved 29 May 2006
Resolution: Recieved Class report attesting to realignment of door frame. Door now has a tight seal.
Construction/Loadline › Hull › Side Shell
Issued 16 May 2005
Resolved
Vessel has damage to port side shell plating in the area of frame #7 at hawser pipe. Doubler on plating is leaking/weeping at the top of the weld.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 26 May 2005
Resolution: Received class report attesting to proper repair.
Construction/Loadline › Hull › Side Shell
Issued 16 May 2005
Resolved
Vessel has damage to starboard side shell plating in the area of frame #6 to #7 at hawser pipe. Multiple indentations to shell plating.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 26 May 2005
Resolution: Received class report attesting to proper repair.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 16 May 2005
Resolved
Port and Starboard lifeboats have damaged/missing rations. Replace 06 food rations prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 May 2005
Resolved 20 May 2005
Resolution: Vessel purchased 06 food rations prior to departure and faxed receipt to Sector Baltimore.
Construction/Loadline › Structures › Door
Issued 16 May 2005
Resolved
Starboard bunker station Port access door leaking at watertight gasket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 26 May 2005
Resolution: Received class report attesting to proper repair.
Engineering › Steam System (auxiliary) › Piping
Issued 16 May 2005
Resolved
Steam return pipe in lower level of main engine room has one soft patch and weeping in numerous areas.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 26 May 2005
Resolution: Received class report attesting to proper repair.
Lifesaving › Lifeboat
Issued 7 February 2004
Resolved
Permanently address inability of motor lifeboat to start in cold weather in accordance with SOLAS/LSA Code (-15 degrees C in 2 minutes). Repair to satisfaction of class by 15 February 2004 or prior to return to U.S., whichever occurs first. LEGACY COMPONENT DESC: Propulsion Engine
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 February 2004
Resolved 10 February 2004
Resolution: Witnessed MLB promptly starting in cold weather.
Lifesaving › Lifeboat Equipment
Issued 25 August 2003
Resolved
VESSEL NEEDS TO REPLACE 30 LIFEBOAT RATIONS. RATIONS WERE NOT AIR TIGHT. SOLAS 74/78 REG.41.1.2 CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Food Ration
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 August 2003
Resolution: RECIEVED FAX FROM SHIP SHOWING RECEIPT FOR THE PURCHASE OF FOOD RATIONS FOR THEIR LIFE BOATS.
Navigation › Collision/Grounding Avoidance
Issued 18 February 2003
Resolved
Vsl requested inbound deviation for 2nd radar, request was granted. Vsl is detained. LEGACY COMPONENT DESC: Radar
Action required: 17 - Rectify deficiencies prior to departure
Due 18 February 2003
Resolved 24 February 2003
Resolution: Recieved technician report attesting to satisfactory repairs and operation.
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2002
Resolved
VESSELS MSD TRANSFER PUMP SEAL WASTED, TRANSFER PUMP LEAKING RAW SEWAGE INTO COMPARTMENT. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 27 March 2002
Resolved 24 April 2002
Resolution: Repaired.
Fire Fighting
Issued 7 October 1999
Resolved
REPAIR SECONDARY CO2 STORAGE TANK RELIEF VALVE TO THE SATISFACTION OF THE CERTIFICATE ISSUING AUTHORITY PER SOLAS 74 UNAMENDED II-2/8._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 January 2000
Resolved 31 January 2000
Lifesaving
Issued 31 May 1996
Resolved
CRACKED COVER OVER LADDER LEADING TO BASE OF STEERING GEAR. ILO 147. CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Navigation
Issued 31 May 1996
Resolved
Inoperative echo depth sounder. Vessel planning to depart soon, allowed vessel to depart, but must repair at sea or failing that prior to departurefrom next U.S. port.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Unknown
Issued 19 July 1995
Resolved
VESSEL'S MAIN DECK WATER-TIGHT HATCHES WERE FOUND TO BE WASTED ALONG KNIFE EDGE. SHIP INSTRUCTED TO REPAIR AT NEXT SCHEDULED DRY-DOCK IN OCTOBER.
Condition: Unknown
Due 5 November 1995
Resolved 5 November 1995
Documentation
Issued 11 July 1986
Resolved
EACH OPERATION IN OIL RECORD BOOK WAS NOT SIGNED BY PERSON IN CHARGE OF OPERATION
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986
Documentation
Issued 11 July 1986
Resolved
PROCEDURES FOR TENDING VESSEL MOORING AND REPORTING OIL DISCHARGES INTO WATER NOT LISTED ON OIL TRANSFER PROCEDURES
Condition: Unknown
Due 11 July 1986
Resolved 11 July 1986