Records from 1985 to 2004. Most recent: inspection, 29 July 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 16
29 July 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 2139824
22 August 2002
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1664966
27 June 2002
Re-Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1635097
17 December 2001
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1477118
25 May 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 278068
3 November 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 434248
23 March 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 426597
9 July 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 418806
25 June 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 416645
8 December 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 385581
9 April 1994
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 365929
15 February 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 341961
25 March 1989
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 329220
26 April 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 315650
14 August 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 303679
19 February 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 513834
Lifesaving › Lifeboat › Propulsion Engine
Issued 29 July 2004
Resolved
Vessel's starboard motor lifeboat was not maintained in a ready condition for sea as required by SOLAS 74 (unammended), Chapter III, Regulation 4(c), in that during operation of the boat the motor failed. Proper operation is to be demonstrated prior to departure from Port.
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 6 August 2004
Resolution: Received class report attesting to repairs and proper operation of the starboard motor lifeboat.
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 29 July 2004
No resolution recorded
Vessel had 3 discharged EEBD's in the engineroom. EEBD's in the engineroom are required by SOLAS 74 (2000 amendments), Chapter II-2, Regulation 13.4.3. EEBD's are required to be recharged prior to departure from port. 06AUG04 - Vessel allowed to sail 1 EEBD short, provided they are all recharged at the next port.
Action required: 705 - Other - as specified
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 29 July 2004
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 6 August 2004
Resolution: Received documentation from the Panama Maritime Authority that the 2nd engineer Phillipino license is equivelant to a 1st engineer Panamanian license. Requirement cleared based on this information.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 29 July 2004
Resolved
Vessel is to provide covers for the naked lights in the engine control room (ILO-147).
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 6 August 2004
Resolution: Light covers were placed on lights in engine control room.
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 29 July 2004
Resolved
Vessel is to provide a MARPOL standard discharge connection meeting the requirements of MARPOL 73/78, Annex I, Regulation 19.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 6 August 2004
Resolution: SDC was provided onboard.
Documentation › Safety/Response Plans/Programs
Issued 23 June 2002
Resolved
Fire Control Plans are inaccurate. They fail to identify proper fire boundries. LEGACY COMPONENT DESC: Fire Control Plans
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 June 2002
Resolved 29 August 2002
Resolution: Fire plan approve by class society.
Pollution Prevention/Response › Prevention Equipment
Issued 23 June 2002
Resolved
There is no fixed containment around the lube oil sludge tank and fuel oil tank vents. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 June 2002
Resolved 29 August 2002
Resolution: Fixed containment is now provided around all vents.
Construction/Loadline
Issued 23 March 1999
Resolved
Modify existing standard discharge connection as outlined in MARPOL 73/78, Reg 19 or replace with approved connection._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Electrical
Issued 23 March 1999
Resolved
Install ventilation in battery room IAW SOLAS II-1,Reg 45,9.1._x001C_
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Construction/Loadline
Issued 23 March 1999
Resolved
Make fitting located in bulkhead above forward Bosun hold watertight door watertight._x001C_ _x001C_
Condition: Unknown
Due 4 November 1999
Resolved 4 November 1999
Fire Fighting
Issued 25 June 1998
Resolved
PROVIDE A SECOND FIREMAN'S OUTFIT TO REPLACE INOPERATIVE FIREMAN'S OUTFIT. OUTFIT'S REGULATOR WAS NOT WORKING PROPERLY.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Navigation
Issued 15 February 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Documentation
Issued 26 April 1987
Resolved
33CFR155.750(A)(1)(I) THE VSL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THEGENERIC OR CHEMICAL NAME OF THE OIL WHICH IS TRANSFERRED BY THE VSL.
Condition: Unknown
Due 26 April 1987
Resolved 26 April 1987
Documentation
Issued 26 April 1987
Resolved
33CFR155.750(A)(1)(II) THE VSL'S OIL TRANSFER PROCEDURES DID NOT CONTAIN THE REQUIRED CARGO INFORMATION AS DESCRIBED IN 33CFR154.310(A)(5)(II).
Condition: Unknown
Due 26 April 1987
Resolved 26 April 1987