← All vessels
PANTANASA
PANTANASA is a 1983 freight ship. The Coast Guard has recorded 13 inspections since 1984, most recently in May 2000, along with 45 deficiencies and 2 operational controls.
Records from 1984 to 2000. Most recent: inspection, 29 May 2000.
- Built
- 1983
- Last inspected
- 29 May 2000
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 45 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
8216758 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B2033
227440
Flag
LIBERIA
—
Maury page id
psix-227440
Inspections, by type
…with no type recorded13
Years with a record
9 calendar years (1984–2000)
The 13 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it9976 - Regulatory (Subpart C or D), Net Ton
18641 - Regulatory (Subpart C or D), Gross Ton
31774 - Dead Weight, Ton
18641 - Regulatory (Subpart C or D), Gross Ton
31774 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 13
29 May 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278386
26 May 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 278387
21 March 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 401690
2 July 1996
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 392775
10 April 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389620
31 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 379109
9 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 689065
1 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 375694
30 August 1993
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 360416
15 October 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 353782
19 January 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320809
19 December 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 306032
24 November 1984
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 299066
Deficiency record · 45
Fire Fighting
Issued 29 May 2000
Resolved
MAKE PERMANENT REPAIR TO G/S PUMP STRAINER IN WAY OF FIRE PUMP.
Fire Fighting
Issued 10 April 1996
Resolved
RENEW MISSING VENTILATION CLOSURE FOR BATTERY STORAGE ROOM LOCATED AFT OF THE PILOT HOUSE. SOLAS 74 (UNAMENDED) II-2/25(c)
Lifesaving
Issued 10 April 1996
Resolved
RENEW DEFECTIVE WATERLIGHTS TO RING LIFE BOUYS. PROVIDE FOUR WATERLIGHTS ATTACHED TO RING LIFE BOUYS IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE. SOLAS 74 (AMENDED) III/19.2
Lifesaving
Issued 10 April 1996
Resolved
PROVIDE AT LEAST TWO RING LIFEBOUYS WITH SELF-IGNITING LIGHTS AND A SELF ACTIVATION SMOKE SIGNAL THAT ARE CAPABLE OF QUICK RELEASE FROM THE NAVIGATING BRIDGE. SOLAS 74(UNAMENDED)III/21(g)
Lifesaving
Issued 10 April 1996
Resolved
PROVIDE AND POST AN EMERGENCY MUSTER LIST AND EMERGENCY INSTRUCTIONS IN A CONSPICUOUS PLACE IN THE ENGINE ROOM. SOLAS 74 (AMENDED) III/8.3
Lifesaving
Issued 10 April 1996
Resolved
PROVIDE LIGHTS FOR LLIFEJACKETS LOCATED IN THE ENGINE CONTROL ROOM. SOLAS 74(AMENDED)III/27.2
Lifesaving
Issued 10 April 1996
Resolved
RENEW DETERIORATED KEEL GRAB RAILS TO PORT AND STARBOARD LIFEBOATS. SOLAS 74 (UNAMENDED) III/11(a)(xvi)
Electrical
Issued 10 April 1996
Resolved
RENEW/REPAIR INOPERABLE LIFEBOAT EMBARKATION LIGHTS FOR PORT AND STARBOARD LIFEBOATS. SOLAS 74 (UNAMENDED II-1/26(a)(ii)(1)
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED/HOLED SEA WATER COOLING SUPPLY PIPE TO THE MAIN SHAFT BEARING. (PORT SIDE)
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPE (6") LOCATED ENGINE ROOM LOWER LEVEL PORT SIDE. PIPE FROM AUXILLIARY SEA WATER COOLING PUMP.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED OVERBOARD DISCHARGE PIPE LOCATED ENGINE ROOMLOWER LEVEL STARBOARD SIDE AFT OVERHEAD.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEWAGE PIPE LOCATED ENGINE ROOM LOWER STARBOARD SIDE AFT OVERHEAD.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED/HOLED SEA WATER COOLING DISCHARGE PIPE FOR THE MAIN SHAFT BEARING, STARBOARD SIDE.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW/REPAIR BROKEN VALVE STEM FOR THE SHAFT BEARING COOLING WATER DISCHARGE ISOLATION VALVE. (STARBOARD SIDE OF BEARING)
Lifesaving
Issued 10 April 1996
Resolved
PROVIDE ON BOARD VESSEL TRAINING MANUALS FOR LIFESAVING APPLIANCES THAT COMPLY WITH THE REQUIREMENTS OF SOLAS 74(AMENDED)II/51. THESE TRAINING MANUALS ARE TO BE IN A LANGUAGE OR LANGUAGES UNDERSTOOD BY THE CREW. SOLAS74(AMENDED)III/18.2/51
Lifesaving
Issued 10 April 1996
Resolved
PROVIDE WHISTLES FOR EACH LIFEJACKET LOCATED IN THE ENGINE CONTROL ROOM. SOLAS 74 III/22(c)
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED PIPING TO THE SEA WATER PRESSURE TANK PUMP LOCATED IN THE ENGINE ROOM LOWER LEVEL STARBOARD SIDE AFT BENEATH DECK PLATES.
Engineering
Issued 10 April 1996
Resolved
TENEW LEAKING PACKING TO SEA WATER PRESSURE TANK PUMP LOCATED IN THE ENGINEROOM LOWER LEVEL STARBOARD SIDE AFT.
Engineering
Issued 10 April 1996
Resolved
PROVIDE ON BOARD VESSEL OIL TRANSFER PROCEDURES THAT COMPLY WITH THE REQUIREMENTS OF 33 CFR 155.750
Lifesaving
Issued 10 April 1996
Resolved
RENEW ALL DEFECTIVE RING LIFEBOUYS. PROVIDE EIGHT RING LIFEBOUYS ON STATION IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMMEDIATE USE. SOLAS 74 (AMENDED) II/19.2
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
TENEW AS ORIGINAL DETERIORATED SEA WATER DISCHARGE PIPE LOCATED STARBOARD SIDE OUTBOARD #1 GENERATOR.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SANITARY PIPING LOCATED STARBOARD SIDE ON THE GENERATOR DECK OVERHEAD IN WAY OF FRAME 22(MARKED)
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORLIGINAL DETERIORATED SEA WATER COOLING PIPE LOCATED IN THE STEERING GEAR ROOM OVERHEAD.
Lifesaving
Issued 10 April 1996
Resolved
REMOVE ALL PAINT AND PAINT THINNERS STORED IN THE ENGINE ROOM.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED 10 INCH SEWAGE DRAIN PIPE LOCATEDSTARBOARD SIDE UPPER LEVEL ENGINE ROOM OUTBOARD.
Fire Fighting
Issued 10 April 1996
Resolved
PROVIDE ON BOARD VESSEL INSTRUCTIONS FOR THE MAINTENANCE AND OPERATION OF ALL INSTALLATIONS AND EQUIPMENT ON BOARD FOR THE FIGHTING AND CONTAINMENT OF FIRE. THESE INSTRUCTIONS ARE TO BE READILY ACCESIBLE AND IN A LANGUAGE/LANGUAGES UNDERSTOOD BY THE CREW. SOLAS 74(AMENDED)II-2/20
Lifesaving
Issued 10 April 1996
Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FFROM WINCH PUMP ROOM DECK LOCATED IN THEFORWARD BOS'N HOLD.
Fire Fighting
Issued 10 April 1996
Resolved
TENEW AS ORIGINAL HOLED FIREMAIN PIPING LOCATED ON THE MAIN DECK SARBOARD SIDE OF #4 CARGO HOLD. SOLAS 74 (AMENDED) II-2/21
Fire Fighting
Issued 10 April 1996
Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT VESSEL. NOTED OVER 50% OF THOSE CHECKED WERE DETERIORATED AND HOLED. ALL FIRE HOSES THROUGHO0UT THE VESSELSHALL BE RENEWED AND/OR PRESSURE TESTED IN THE PRESENCE OF THE ATTENDING U.S. COAST GUARD MARINE INSPECTOR. SOLAS 74 (AMENDED) II-2/21
Electrical
Issued 10 April 1996
Resolved
RENEW/REPAIR BROKEN EMERGENCY LIGHT LOCATED ON THE POOP DECK.
Electrical
Issued 10 April 1996
Resolved
RENEW/REPAIR ALL BROKEN/INOPERABLE DECK LIGHTING THROUGHOUT THE VESSEL.
Lifesaving
Issued 10 April 1996
Resolved
RENEW DETERIORATED LIFEBOAT GRABLINES (LIFELINE) TO PORT AND STARBOARD LIFEBOATS. SOLAS 74 III/11(a)(viii)_x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER DISCHARGE PIPE LOCATED PORT SIDE OUTBOARD #3 GENERATOR.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE TO #2 GENERATOR. PIPE IS LOCATED BENEATH DECK PLATES FORWARD OF #2 GENERATOR.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPLY PIPE (3" PIPE) LOCATED BENEATH DECK PLATES FORWARD OF #3 GENERATOR.
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER COOLING SUPPL PIPE (5" PIPE) LOCATED BENEATH DECK PLATES FORWARD OF F#3 GENERATOR._x001C_
Accommodation/Occupational Safety
Issued 10 April 1996
Resolved
RENEW AS ORIGINAL DETERIORATED SEWAGE PIPE LOCATED PORT SIDE AFT OUTBOARD OF #3 GENERATOR.
Documentation
Issued 1 March 1995
Resolved
PROVIDE THE SOLAS DOCUMENTS FOR INSPECTION PRIOR TO DEPARTURE.
Fire Fighting
Issued 1 March 1995
Resolved
MAKE PERMANENT REPAIR OF FIREMAIN SYSTEM LEAK LOCATED ON THE MAIN DECK STBDSIDE OF FWD DECK HOUSE. TEMPORARY REPAIR IS AUTHORIZED UNTIL 01APR95.
Lifesaving
Issued 1 March 1995
Resolved
CLEAN ALL OIL FROM THE DECK IN THE STEERING COMPARTMENT.
Accommodation/Occupational Safety
Issued 1 March 1995
Resolved
PROVE OPERATION OF TOILETS IN CREW LIVING QUARTERS PRIOR TO DEPARTURE.
Engineering
Issued 1 March 1995
Resolved
PROVIDE A COMPLETE AND CURRENT COPY OF THE VESSEL OIL TRANSFER PROCEDURES.
Lifesaving
Issued 1 March 1995
Resolved
REMOVE OPEN OIL DRUMS FROM MAIN DECK PRIOR TO DEPARTURE.
Documentation
Issued 1 March 1995
Resolved
OPERATIONS IN THE OIL RECORD BOOK WERE NOT SIGNED BY THE PERSON IN CHARGE.
Fire Fighting
Issued 1 March 1995
Resolved
MAKE PERMANENT REPAIR TO LEAKY FIREMAIN COUPLING LOCATED STBD SIDE AFT #3 CARGO HOLD PRIOR TO DEPARTURE. TEMPORARY REPAIR IS AUTHORIZED. UNTIL 01APR95.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.