MAURY USCG vessel records Sign in
← All vessels

ZHEN HUA 8

ZHEN HUA 8 is a 1980 freight ship. The Coast Guard has recorded 31 inspections since 1985, most recently in December 2004, along with 21 deficiencies and 1 operational control.

Records from 1985 to 2004. Most recent: operational control imposed, 30 December 2004.

Built
1980
Last inspected
30 December 2004
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7800784 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B2817
227499
Flag
NORWAY
—
Maury page id
psix-227499

Inspections, by type

…with no type recorded18
Years with a record 10 calendar years (1985–2004)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 22 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it37456 - Convention (Subpart B), Gross Ton
88723 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JOSEPH ROY DEE Towing Vessel · MISLE 110069 · 24 July 1994 · activity 183188VLB 9174 Freight Barge · MISLE 353231 · 24 July 1994 · activity 183188

Inspection history · 31

30 December 2004 PII Safety Exam · ISPS II Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2266460
27 July 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 431149
27 July 1999 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1105405
16 August 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 381267
20 September 1994 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 870184
29 August 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 696126
25 July 1994 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1394158
24 July 1994 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 183188
22 July 1994 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 144860
18 July 1994 Tank Vessel Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367103
21 January 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165414
15 November 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 11879
3 November 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 466794
4 October 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 441121
15 April 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150615
13 April 1993 MARPOL Annex I Examination · Certificate of Compliance
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1150466
4 October 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 470509
9 July 1992 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1254614
31 March 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 349784
12 July 1991 Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1245207
1 April 1991 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 440947
9 February 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 341926
9 February 1991 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232534
20 July 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 338318
20 July 1990 MARPOL Annex II Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916577
12 March 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 335763
12 March 1990 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 924058
20 June 1986 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 309611
19 June 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 486657
1 May 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 474562
16 January 1985 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 505648

Deficiency record · 21

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 30 December 2004 Resolved
Oily Water Separator oil content meter is overdue for calibration and is currently out of calibration. Conduct repairs/replacement and or recalibrate the oil content meter and conduct test of Oily Water Separator to the satisfaction of class prior to departing the Port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 January 2005
Resolved 4 January 2005
Resolution: RECEIVED CLASS REPORT ATTESTING TO REPAIRS.
Documentation › Markings/Placards › Oil Discharge Placard
Issued 30 December 2004 Resolved
Provide missing oil discharge placard in engine room. Install placarding I.A.W. 33CFR155.450 to the satisfaction of attending Coast Guard marine inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 June 2014
Resolution: Examiners attended the vessel to visually inspect the above mentioned condition. Oil discharge placard has been installed IAW 33CFR155.450.
Construction/Loadline › Markings › Load Line Mark
Issued 30 December 2004 Resolved
Vessel Deck Load Line mark is not painted contrasting color to hull. Paint deck line contrasting color I.A.W. ICLL 66 CH1, REG 8, to the satisfaction of attending classification surveyor.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 June 2014
Resolution: Examiners reviewed Report of Survey from China Classification Society (dated 11APR05) and visually inspected the vessel to clear/rectify the above mentioned condition. Port and Starboard deck lines are painted in a color that is in contrast to the hull
Operations/Management › Drills/Instruction › Abandon Ship
Issued 30 December 2004 Resolved
Conduct abandonship drill to the satifaction of attending Coast Guard inspector. Crew was not familiar with abandon ship procedures and lifeboat launching arrangements. STCW 95 VI/1. To be conducted prior to departing Port of Hampton Roads.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2005
Resolved 5 January 2005
Resolution: Conducted satisfactory abandon ship drill in presence of Coast Guard Inspector.
Lifesaving › Launching Appliances › Release Mechanism
Issued 30 December 2004 Resolved
Port and Starboard lifeboat release hooks to be surveyed and tested. Port lifeboat release hooks did not release upon activation. To be conducted to the satisfaction of class and prior to departing the Port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2005
Resolved 5 January 2005
Resolution: Rcvd class report attesting to repairs of portside release hooks. It is confirmed there is no problem for the above mentioned operation. Stbd can not be tested due to ship being moored pier stbd.
Accommodation/Occupational Safety › Ventilation › General
Issued 30 December 2004 Resolved
Repair electrical exhaust ventilation fan motor in CO2 storage/activation room to the satisfaction of class surveyor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 June 2014
Resolution: Examiners reviewed Report of Survey from China Classification Society (dated 11APR05) and visually inspected the vessel to clear/rectify the above mentioned condition. Electrical exhaust ventilation fan motor in CO2 room is operating properly.
Lifesaving › Launching Appliances › Release Mechanism
Issued 30 December 2004 Resolved
Conduct repairs to the Port lifeboat manual release/drop cable. Manual release/drop cable not attached to the lifeboat and not operational. Repairs to be conducted to the satisfaction of class surveyor prior to departing the Port of Hampton Roads.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 3 January 2005
Resolved 5 January 2005
Resolution: Rcvd class report attesting to repairs for port side release/drop cable.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 30 December 2004 Resolved
Properly seal open bulkhead penetration to CO2 aft bulkhead storage room. A 1/4" copperl line was installed thru the bulkhead from CO2 discharge piping, but does not meet structural fire protection requirements. To be corrected to the satisfaction of attending classification society surveyor.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 30 June 2014
Resolution: Examiners reviewed Report of Survey from China Classification Society (dated 11APR05) and visually inspected the vessel to clear/rectify the above mentioned condition. Bulkhead penetration has been sealed with a steel plate.
Lifesaving › Launching Appliances › Release Mechanism
Issued 30 December 2004 Resolved
Starboard lifeboat release hooks to be surveyed and tested. To be conducted to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2005
Resolved 30 June 2014
Resolution: Examiners reviewed Report of Survey from China Classification Society (dated 4JAN05) and visually inspected the vessel to clear/rectify the above mentioned condition. Class Surveyor tested and inspected lifeboat release hooks. All satisfactory.
Electrical › Electric Generation Source (service) › Generator
Issued 27 July 1999 Resolved
STEAM TURBINE INOPERABLE. PROVIDE CLASS REPORT PROVING PROPER OPERATION.
Condition: Unknown
Due 27 August 1999
Resolved 30 December 2004
Resolution: Cleared item.
Electrical
Issued 27 July 1999 Resolved
NO.1 DIESEL GENERATOR HAS OIL AND WATER LEAKS COMING FROM NO'S 3 & 4 CYLINDER HEADS. PROVIDE CLASS REPORT PROVING PROPER OPERATION.
Condition: Unknown
Due 27 July 1999
Resolved 28 July 1999
Engineering › Steam Boiler (auxiliary/waste heat) › Valve, Relief
Issued 27 July 1999 Resolved
REPAIR LEAKING JACKET WATER AUTOMATIC REGULATING VALVE.
Condition: Unknown
Due 30 December 2004
Resolved 30 December 2004
Resolution: Cleared item.
Engineering › Steam Boiler (auxiliary/waste heat) › Pump
Issued 27 July 1999 Resolved
MAIN ENGINE EXHAUST BOILER COOLING WATER PUMP SEALS LEAKING EXCESSIVELY. REPLACEOR REPAIR AS NEEDED.
Condition: Unknown
Due 27 August 1999
Resolved 30 December 2004
Resolution: Cleared item.
Engineering › Freshwater System (air cooling) › Pump
Issued 27 July 1999 Resolved
A/C COOLING PUMP SEAL LEAKING EXCESSIVELY. REPLACE SEAL
Condition: Unknown
Due 27 August 1999
Resolved 30 December 2004
Resolution: Cleared item.
Lifesaving
Issued 16 August 1995 Resolved
Provide proof (via servicing certificates from authorized liferaft servicing facility) that liferafts have been properly serviced prior to departure from Guayanilla, Puerto Rico._x001C_
Condition: Unknown
Due 16 August 1995
Resolved 21 August 1995
Lifesaving
Issued 18 July 1994 Resolved
RENEW WASTED LIFEBOAT EMBARKATION ROPE LADDERS.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Navigation
Issued 18 July 1994 Resolved
PROVIDE ADAQUATE COMMUNICATIONS BETWEEN THE STEERING GEAR ROOM AND THE BRIDGE.
Condition: Unknown
Due 18 July 1994
Resolved 18 July 1994
Engineering
Issued 13 April 1993 Resolved
PROVIDE PROPER OPERATION OF HIGH GAS TEMPERATURE ALARM AND SHUTDOWN FOR INERT GAS SYSTEM, DOWNSTREAM OF THE BLOWERS. CLASS SOCIETY REPORT FOR CLEARING DEF MAYBE FAXED TO MIONY, PRIOR TO NEXT U.S. PORT._x001C_ _x001C_
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Deck/Cargo
Issued 12 March 1990 Resolved
FLAME SCREEN ON #6 CENTER CARGO TANK VENT MISSING
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Navigation
Issued 12 March 1990 Resolved
VESSEL'S MANEUVERING FACT SHEET ON THE BRIDGE DID NOT HAVE THE WARNING STATEMENT ON IT AS REQUIRED BY 33CFR164.35(G)(7)
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990
Deck/Cargo
Issued 12 March 1990 Resolved
FLAME SCREEN ON #5 CENTER CARGO TANK VENT TORN.
Condition: Unknown
Due 12 March 1990
Resolved 12 March 1990

Ownership record