MAURY USCG vessel records Sign in
← All vessels

WIN SHENG

WIN SHENG is a 1979 freight ship. The Coast Guard has recorded 8 inspections since 1984, most recently in January 2010, along with 20 deficiencies.

Records from 1984 to 2010. Most recent: inspection, 28 January 2010.

Built
1979
Last inspected
28 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7810571 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227584
Flag
UNKNOWN
—
Maury page id
psix-227584

Inspections, by type

…with no type recorded5
Years with a record 7 calendar years (1984–2010)
The 8 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1395 - Regulatory (Subpart C or D), Net Ton
2500 - Regulatory (Subpart C or D), Gross Ton
4360 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 8

28 January 2010 MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3673722
2 March 2005 Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2302526
29 November 2004 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2254392
1 December 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 715741
18 November 1995 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 384779
1 September 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 325402
22 July 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 317476
28 November 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 299063

Deficiency record · 20

Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 28 January 2010 Resolved
Provide panel for electrical switch in galley
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2010
Lifesaving › Lifebuoys › Immediately Available
Issued 28 January 2010 Resolved
Conduct maintenance on port and stbd bridgewing quick release setup to ensure quick release of life rings.
Due 8 February 2010
Resolved 20 April 2010
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 28 January 2010 Resolved
Provide alarm or means to open reefer doors from within reefer space.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2010
Accommodation/Occupational Safety › Ventilation › General
Issued 28 January 2010 Resolved
Provide a filter and clean grease fom vent over galley cooking area.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2010
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 28 January 2010 Resolved
Found bilge alarm loose and tied off. Ensure bilge alarm is mounted properly in bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 January 2010 Resolved
Remove dead end wire located in hospital space.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 April 2010
Lifesaving › Inflatable Liferafts › Weak Link
Issued 29 November 2004 Resolved
Ensure both life rafts are stowed as deisigned with proper weak links.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 29 November 2004 Resolved
Ensure port side repeater is in sync with main gyro. Port gyro repeater off by 40 degrees.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Navigation › Piloting/Steering › Swing Meter
Issued 29 November 2004 Resolved
Bridge and steering gear room off by 3 degree's. Ensure both are within 1 degree of each other.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Lifesaving › Inflatable Liferafts › Not on Board
Issued 29 November 2004 Resolved
Provide additional 6 person SOLAS "A" approved life raft at bow.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 29 November 2004 Resolved
Stow away numerous paint cans and solvents in bosun store and place in paint locker.
Due 1 December 2004
Resolved 29 November 2004
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 29 November 2004 Resolved
Provide rubber matting behind switch board in control room.
Action required: 15 - Rectify deficiencies by next port
Resolved 22 January 2005
Resolution: Not required
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 29 November 2004 Resolved
Repair all reefer door escape mechanisms to allow operation of reefer door from the inside.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 November 2004 Resolved
Repair numerous spliced electrical wiring in crew cabins.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 November 2004 Resolved
Place guard over moving fan blade for freezer located in galley.
Action required: 15 - Rectify deficiencies by next port
Resolved 2 March 2005
Navigation
Issued 18 November 1995 Resolved
The vessel carried an outdated Coast Guard Light List from 1994 instead of the current edition in accordance with 33 C.F.R. 164.33(a)(2)(ii).
Condition: Unknown
Due 19 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 November 1995 Resolved
The vessel carried an outdated U.S. Coast Pilot from 1988 instead of the current edition in accordance with 33 C.F.R. 164.33(a)(2)(i).
Condition: Unknown
Due 19 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 18 November 1995 Resolved
The vessel did not log the pre-arrival tests in accordance with 33 C.F.R. 164.25.
Condition: Unknown
Due 19 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 18 November 1995 Resolved
The vessel carried no valid oil transfer procedures aboard in accordance with 33 C.F.R. 155.750.
Condition: Unknown
Due 19 December 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 1 September 1988 Resolved
VSL DID NOT HAVE A POLLUTION PLACARD STATING" DISCHARGE OF OIL IS PROHIBITED" ON BOARD.
Condition: Unknown
Due 1 September 1988
Resolved 1 September 1988

Ownership record