Records from 1984 to 2002. Most recent: inspection, 23 January 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
23 January 2002
Annual Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1480024
18 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 128045
15 May 2001
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 290030
16 October 2000
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 282974
22 November 1999
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 434642
24 October 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 434059
2 November 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 422143
14 February 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 522765
17 August 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 352624
3 March 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 532687
6 June 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 484972
6 June 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 497492
15 September 1990
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 339361
25 April 1990
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 514241
3 August 1989
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 331804
21 March 1988
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 322112
19 March 1988
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 322144
8 March 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 321826
7 April 1987
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 315480
9 January 1987
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 467757
4 April 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307986
26 September 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 489047
4 March 1985
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 300647
4 October 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 466081
Fire Fighting › Fire Hoses
Issued 23 January 2002
Resolved
During the course of conducting fire main pressure test, 15 of 26 2.5" fire hoses proved defective. Vsl was required to obtain 15 new hoses which they did prior to departing. However, class verification is required for approval of the hose clamps used to secure the fittings to the hoses. LEGACY COMPONENT DESC: Connections
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 23 January 2002
Fire Fighting › Fire Hoses › Connections
Issued 23 January 2002
Resolved
Found two gaskets for fire hose nozzles that were worn/deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2002
Resolution: Replaced with new gaskets
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 23 January 2002
Resolved
Vsl was required to hire a contractor to certify that the Fixed CO2 system was up to par.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2002
Resolution: Contractor inspected and certified system
Deck/Cargo › Cargo Stowage
Issued 23 January 2002
Resolved
unnecesssary items stowed in hospital room LEGACY COMPONENT DESC: Hospital Space
Due 26 January 2002
Resolved 26 January 2002
Resolution: ALL ITEMS REMOVED FROM HOSPITAL SPACE
Lifesaving › Lifeboat › Propulsion Engine
Issued 23 January 2002
Resolved
ENGINE DID NOT START DUE TO BROKEN CHAIN
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 January 2002
Resolved 26 January 2002
Resolution: MADE REPAIRS ON ENGINE.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 January 2002
Resolved
MISSING LIGHT PROTECTIVE GLOBE
Condition: Improper/Lack of Maintenance
Due 26 January 2002
Resolved 26 January 2002
Resolution: REPLACED LIGHT PROTECTIVE GLOBE.
Navigation
Issued 24 October 1999
Resolved
Provide a radio direction finder or provide an exemption from flag administration prior to 24NOV99.
Condition: Unknown
Due 23 November 1999
Resolved 23 November 1999
Lifesaving
Issued 24 October 1999
Resolved
Remove the excessive fuel oil from and around the ship's service generator spaces prior to the next U.S. port call.
Condition: Unknown
Due 22 November 1999
Resolved 22 November 1999
Navigation
Issued 8 March 1988
Resolved
AUTOMATIC RADAR PLOTTING AID (ARPA) REQUIRED UNDER 33CFR164.38(B) TO BE ONBOARD DID NOT HAVE A PERMANTENTLY AFFIXED LABEL STATING THAT THE DEVICE COMPLIED WITH IMO STANDARDS FOR ARPAS AS PER 33CFR164.38(D)(1)(II).
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 8 March 1988
Resolved
CHART 18720 25ED. (1984) ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(A)(1). FOLLOWING NTM CORRECTIONS NOT POSTED: 87/27-37-43-50. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 8 March 1988
Resolved
U.S. COAST PILOT VOL. 7, 1986ED. ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33. FOLLOWING NTM CORRECTIONS NOT POSTED: 87/21-30-35-38. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 8 March 1988
Resolved
CHART 18740 30ED. (1986) ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(A)(1). FOLLOWING NTM CORRECTIONS NOT POSTED: 87/18-34-38-49. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 8 March 1988
Resolved
CHART 18746 25ED (1986) ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(A)(1). FOLLOWING NTM CORRECTIONS NOT POSTED: 87/34-48-49. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 8 March 1988
Resolved
CHART 18751 31ED. (1986) ONBOARD BUT NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(A)(1). FOLLOWING NTM CORRECTIONS NOT POSTED: 87/8-9-10-25-31-34-36-41-48. NO FOREIGN EQUIVALENTS ONBOARD.
Condition: Unknown
Due 8 March 1988
Resolved 8 March 1988
Navigation
Issued 7 April 1987
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. CHARTS 12230,12263,12278,& 12281, USED BY THE VSL, WERE NOT CORRECTED TO NTM 46/86, 46/86, 8/87, 42/86, RESPECTIVELY, WHICH WERE REASONABLY AVAILABLE AND CONTAINED CORRECTIONS APPLICABLE TO THE VSL'S ROUTE FROM SMITH PT.TO BALTIMORE,MD.
Condition: Unknown
Due 7 April 1987
Resolved 7 April 1987