MAURY USCG vessel records Sign in
← All vessels

FUJI REEFER

FUJI REEFER is a 1979 freight ship. The Coast Guard has recorded 25 inspections since 1987, most recently in October 2008, along with 18 deficiencies — 4 with no resolution recorded — and 3 operational controls.

Records from 1987 to 2008. Most recent: inspection, 15 October 2008.

Built
1979
Last inspected
15 October 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7812177 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227604
Flag
LIBERIA
—
Maury page id
psix-227604

Inspections, by type

…with no type recorded18
…past their stated due date4
Years with a record 14 calendar years (1987–2008)
The 25 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it3180 - Convention (Subpart B), Net Ton
7095 - Convention (Subpart B), Gross Ton
8084 - Dead Weight, Ton
12487 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 25

15 October 2008 PII Safety Exam · MARPOL Annex V Examination · ISPS II Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3340758
22 October 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3084645
15 October 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3075578
11 October 2007 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3077873
1 November 2005 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2535810
29 October 2005 ISPS I Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2524496
29 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2526144
15 June 2005 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2391344
25 November 2004 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2248398
24 November 2004 ISPS II Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2247365
24 November 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2247710
1 March 2002 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1490335
5 March 1998 Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 413425
28 October 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 409228
20 March 1997 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 401658
23 January 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 652015
19 January 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399660
6 July 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 652012
17 June 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 537677
10 May 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 469388
10 May 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 343671
7 May 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 343583
29 April 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 336790
24 January 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 328120
31 May 1987 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 316468

Deficiency record · 18

Engineering › Lubricating Oil Service System › Cooler
Issued 15 October 2008 No resolution recorded
The sea water pipe for the No. 2 auxiliary engine lube oil cooler is holed and leaking.
Action required: 705 - Other - as specified
Due 22 October 2008 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 15 October 2008 No resolution recorded
The steam supply pipe for heating No. 4c fuel oil tank is holed and leaking.
Action required: 705 - Other - as specified
Due 22 October 2008 — due date passed with no resolution recorded
Engineering › Diesel Engine (auxiliary) › Turbocharger
Issued 15 October 2008 No resolution recorded
The turbo charger cooling water pipe for No. 2 auxiliary engine has a temporary patch.
Action required: 705 - Other - as specified
Due 14 November 2008 — due date passed with no resolution recorded
Engineering › Sea-water System (primary cooling) › Pump
Issued 15 October 2008 No resolution recorded
The sea water cooling pump for No. 3 auxiliary engine is leaking water at the pump seal.
Action required: 705 - Other - as specified
Due 22 October 2008 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Radar
Issued 15 October 2007 Resolved
he master reported that the port side radar is inoperable. PSCO confirmed the same. The master has reported the inop radar to his company and arrangements have been made to have radar repaired while the vessel is in New Orleans.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 October 2007
Resolved 15 October 2007
Resolution: Recieved tech report from Sperry Marine Service Net satisfying requirement.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 1 March 2002 Resolved
VESSEL'S STEERING GEAR COMPARTMENT HAD HYDRAULIC OIL ON THE DECK OUTSIDE OF THE STEERING GEAR FOUNDATION/CONTAINMENT CREATING A SLIP HAZARD FOR PERSONEL, A VIOLATION OF SOLAS 60 CH I REG 11(a). CORRECT PRIOR TO NEXT U.S. VOYAGE.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 8 March 2002
Resolved 25 November 2004
Resolution: LEAKING PIPING WAS REPAIRED AND DECK CLEANED UP OF ALL OIL.
Construction/Loadline
Issued 28 October 1997 Resolved
BILGE SUCTION PIPING (PORT SIDE ENGINE ROOM) HAS A SOFT PATCH INSTALLED. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Fire Fighting
Issued 28 October 1997 Resolved
EMERGENCY FIRE PUMP CEASED DURING OPERATIONAL TEST (CASUALTY). REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Engineering
Issued 28 October 1997 Resolved
SPRING CLOSURE VALVES ON THE FUEL OIL SETTLING TANK (FORWARD ENGINEROOM) HAD MECHANICAL GAGS INSTALLED TO KEEP THEM OPEN AT ALL TIMES. REMOVE VALVES.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Accommodation/Occupational Safety
Issued 28 October 1997 Resolved
PORT SIDE MARINE SANITATION DEVICE (TYPE 3) HAD LEAKS ON THE FRONT SIDE IN WAY OF THE MANWAY, AND ON IT'S STBD SIDE AT THE CLEAN OUT PORT. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 5 March 1998
Resolved 5 March 1998
Engineering
Issued 28 October 1997 Resolved
OIL TRANSFER PROCEDURES INCOMPLETE. PROVIDE COMPLETE PROCEDURES PRIOR TO NEXT TRANSFER IN U.S. WATERS.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Electrical
Issued 28 October 1997 Resolved
LIGHT FIXTURE (IN FORCASTLE STORE ROOM) BROKEN AND HANGING BY IT'S WIRING. REPAIR/RENEW.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Electrical
Issued 28 October 1997 Resolved
LIGHT BRACKET IN PAINT LOCKER BROKEN (WIRE USED TO HOLD THE BRACKET IN PLACE). REPAIR/RENEW.
Condition: Unknown
Due 3 November 1997
Resolved 3 November 1997
Navigation
Issued 19 January 1996 Resolved
REQUIRED NOAA CHARTS 18746 AND 18751 WERE OUTDATED AND NOT CORRECTED AT ALL. VESSEL OBTAINED CORRECTED EQUIVALENT BA CHARTS 1063 AND 1081 PRIOR TODEPARTURE.
Condition: Unknown
Due 21 January 1997
Resolved 21 January 1997
Deck/Cargo
Issued 7 May 1991 Resolved
33 CFR 155.320 (a)_x001C_ FUEL OIL VALVE PROTRUDED PAST CONTAINMENT AREA.
Condition: Unknown
Due 25 March 1997
Resolved 25 March 1997
Documentation
Issued 7 May 1991 Resolved
33 CFR 155. (a)(1)(ii)_x001C_ OIL TRANSFER PROCEDURES DO NOT CONTAIN CARGO INFORMATION.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Navigation
Issued 24 January 1989 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. COAST PILOT VOL.3 OR ITS FOREIGN EQUIVALENT WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM CAPE HENLOPEN, DE TO CAMDEN, NJ.
Condition: Unknown
Due 10 May 1991
Resolved 24 January 1989
Navigation
Issued 24 January 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 10 May 1991
Resolved 24 January 1989

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.