Records from 1984 to 2007. Most recent: inspection, 9 July 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 20
9 July 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2989734
8 February 2007
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2869216
8 February 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2869269
2 February 2007
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2866182
30 June 2004
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2116029
7 January 2002
Passenger/Freight Vessel Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1476197
8 August 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 280780
5 August 2000
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 280786
25 December 1998
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 423848
29 May 1998
Type not recorded
No type recorded · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 416429
13 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 716483
7 January 1997
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 399327
15 December 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 385778
3 April 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 377399
27 February 1995
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 375298
8 July 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 359436
10 April 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 517151
4 March 1992
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 349213
13 January 1990
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 334678
18 September 1984
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 298048
Lifesaving › Lifebuoys › Serviceable
Issued 8 February 2007
Resolved
Lifebuoy with light on port side, just forward of superstructure, in disrepair.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Resolution: Replace Lifebuoy.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 February 2007
Resolved
Fuel oil overflow pipe, port side, main deck, by air vent W.B.T #3, has a soft patch and some visible leakage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 9 July 2007
Resolution: Recieved class report attesting to repairs. Also went to the vessel verify deficiency was corrected
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 8 February 2007
Resolved
Scupper pipe from provision room is wasted and leaking on electrical light.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 February 2007
Resolution: Pipe was cropped and wasted section was replaced. Ships personnel corrected the problem.
Engineering › Steering Gear System › Rudder Angle Indicator
Issued 8 February 2007
Resolved
Classification society to inspect and calibrate rudder angle indicators on bridge and in steering gear room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 March 2007
Resolved 9 July 2007
Resolution: Recieved class report attesting to the repairs, also went on board the vessel to verify the deficiency was corrected.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 30 June 2004
Resolved
11 FOOD RATIONS ON PORT LIFE BOAT LOST VACUUM SEAL. PROVIDE PROOF OF PURCHASE PRIOR TO DEPARTURE. CITE: LSA CODE 4.1.5..18
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2004
Resolution: Invoice was recieved stateing vessel pechased 12 new rations.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 7 January 2002
Resolved
Require Class Report to Verify Compliance With IOPP Certificate within 30 Days (07FEB01).
Condition: Improper Installation
Due 7 February 2002
Resolved 7 February 2007
Resolution: Vessel in compliance with IOPP Certificate.
Pollution Prevention/Response › Prevention Equipment › Automatic Back Pressure Shut-off
Issued 7 January 2002
Resolved
Excess Oil in Bilge. Clean Prior to Return to U.S. Waters.
Action required: 15 - Rectify deficiencies by next port
Resolved 7 February 2007
Resolution: Bilges cleaned.
Lifesaving
Issued 5 August 2000
Resolved
Prove proper operation of the water tight door closure alarm in way of shaft alley.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Lifesaving
Issued 5 August 2000
Resolved
Remove excess fuel oil and lube oil from the main machinery and high heat producing equipment.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Lifesaving
Issued 5 August 2000
Resolved
The liferafts were improperly installed without a weak link to allow the raft to seperate from the ship. Temporary links were fabricated by ships personnel. Permenant replacements are required prior to 09AUG00.
Condition: Unknown
Due 10 August 2000
Resolved 10 August 2000
Lifesaving
Issued 29 May 1998
Resolved
VESSEL IS TO INSTALL SAFETY GLOBES/LENSES, WHERE MISSING, FOR ALL LIGHTS PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 25 December 1998
Resolved 25 December 1998
Fire Fighting
Issued 29 May 1998
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE EMERGENCY FIRE PUMP REQUIRED BY SOLAS 60, CH.II, REG. 56, PRIOR TO DEPARTURE FROM PORT. CLASS REPORT IS ALSO REQUIRED ATTESTING TO SAID REPAIRS.
Condition: Unknown
Due 1 June 1998
Resolved 22 June 1998
Accommodation/Occupational Safety
Issued 29 May 1998
Resolved
VESSEL IS TO REPLACE THE WASTED INSULATION ON THE TYPE II MARINE SANITATIONDEVICE PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 25 December 1998
Resolved 25 December 1998
Lifesaving
Issued 29 May 1998
Resolved
VESSEL IS TO INSTALL PROTECTIVE HEAT WRAP, WHERE MISSING, FOR THE EXHAUST PIPING ON THE EMERGENCY FIRE PUMP PRIOR TO THE NEXT U.S. PORT.
Condition: Unknown
Due 25 December 1998
Resolved 25 December 1998
Navigation
Issued 7 January 1997
Resolved
U.S. COAST PILOT NOT CURRENTLY CORRECTED (39/95). CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Navigation
Issued 7 January 1997
Resolved
VSL MISSING CORRECTIONS FOR U.S. CHART 18749 & 18751, OR EQUIVALENT. CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Engineering
Issued 15 December 1995
Resolved
VESSEL UNABLE TO PROVE PROPER OPERATION OF OILY WATER SEPARATOR.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Fire Fighting
Issued 15 December 1995
Resolved
INTERNATIONAL SHORE CONNECTION MISSING GASKET AND EIGHT (8) WASHERS.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Unknown
Issued 15 December 1995
Resolved
FIRE CONTROL AND LIFESAVING PLANS ARE OUTDATED. LIFESAVING PLAN SHOWS ONLYONE LIFERAFT ON BOARD, BUT VESSEL HAS FOUR. FIRE CONTROL PLAN SHOWS OLD LOCATION OF INTERNATIONAL SHORE CONNECTION.
Condition: Unknown
Due 19 December 1995
Resolved 19 December 1995
Lifesaving
Issued 27 February 1995
Resolved
REQUIRED LIFERAFTS ON VESSEL DID NOT HAVE WEAK-LINKS. SOLAS 74/78 CHPT III
Condition: Unknown
Due 27 February 1995
Resolved 7 March 1995
Navigation
Issued 4 March 1992
Resolved
VESSELS N.O.S. CHARTS 18720,18740,18746,18749, AND 18751 WERE NOT CORRECTEDTO DATE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Navigation
Issued 4 March 1992
Resolved
VESSEL DID NOT HAVE A COPY OF THE INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Navigation
Issued 4 March 1992
Resolved
VESSELS COAST PILOT VOL. 7 WAS NOT CORRECTED TO DATE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Navigation
Issued 4 March 1992
Resolved
VESSELS U.S.C.G. LIGHT LIST WAS NOT CORRECTED TO DATE.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Documentation
Issued 4 March 1992
Resolved
VESSELS OIL TRANSFER PROCEDURES DID NOT CONTAIN ALL THE REQUIRED INFORMATION.
Condition: Unknown
Due 5 March 1992