← All vessels
BUENA FORTUNA
Freight Ship · Bulk Carrier class · USCG Heartland District (CGD-H) · Other hulls named BUENA FORTUNA
BUENA FORTUNA is a freight ship. The Coast Guard has recorded 45 inspections since 1984, most recently in March 2006, along with 17 deficiencies and 4 operational controls.
Records from 1984 to 2006. Most recent: inspection, 14 March 2006.
- Built
- Not recorded
- Last inspected
- 14 March 2006
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 17 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7814096 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J4FE
227621
Flag
GREECE
—
Maury page id
psix-227621
Inspections, by type
The 45 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it34833 - Displacement, Metric Ton
24478 - Dead Weight, Metric Ton
8715 - Convention (Subpart B), Net Ton
13761 - Regulatory (Subpart C or D), Gross Ton
17356 - Convention (Subpart B), Gross Ton
24478 - Dead Weight, Metric Ton
8715 - Convention (Subpart B), Net Ton
13761 - Regulatory (Subpart C or D), Gross Ton
17356 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 45
14 March 2006
Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2597239
13 July 2005
PII Safety Exam · ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2422670
30 August 2004
PII Safety Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2189379
28 June 2004
ISPS II Exam
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2114442
16 April 2004
Re-Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2045286
12 September 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1904389
18 June 2003
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1820677
3 April 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1767500
16 December 2002
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1717938
29 May 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1619913
27 March 2002
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1597975
25 March 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1598464
30 August 2001
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 293362
4 September 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 281779
29 May 2000
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 278239
13 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 436132
12 November 1999
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 79339
9 October 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 433659
23 April 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 427821
18 October 1998
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 421656
8 October 1998
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 420808
16 August 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 406768
23 September 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 395730
29 August 1996
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 394880
16 June 1995
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 379171
6 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 491206
19 April 1994
Type not recorded
No type recorded · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 366231
19 April 1994
Uninspected Other
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1387502
3 December 1993
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 362786
8 June 1993
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 517046
6 December 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 354868
31 October 1992
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 354430
20 May 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 436705
29 August 1991
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 345468
26 April 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 336674
7 April 1989
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 488585
8 July 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 324378
6 July 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 324485
12 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 488718
10 July 1987
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 317197
4 December 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 513298
16 July 1986
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 310156
4 August 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 509662
22 January 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 300025
7 July 1984
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 296848
Deficiency record · 17
Pollution Prevention/Response › Prevention Equipment
Issued 29 May 2002
Resolved
REMOVE POSSIBLE BYPASS VALVE LOCATED ON THE DISCHARGE PIPING AND REPAIR TO THE SAFISFACTION OF CLASS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Pollution Prevention/Response › Prevention Equipment
Issued 29 May 2002
Resolved
REPAIR / REPLACE PRESSURE GAUGE LOCATED ON PUMP OF MARINE SANITATION DEVICE LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 29 May 2002
Resolved
REPAIR/REPLACE PORTABLE FIRE EXTINGUISHERS BRACKETS THAT ARE WASTED. LEGACY COMPONENT DESC: Mounting Bracket
Engineering › Generator (propulsion/auxiliary-electric)
Issued 29 May 2002
Resolved
REMOVE OR PROVIDE PROPER CONTAINMENT FOR USED BATTERIES IN BATTERY ROOM. LEGACY COMPONENT DESC: Battery
Fire Fighting › Combustible Materials
Issued 29 May 2002
Resolved
PROVIDE BRACKETS FOR ALL LOOSE GAS CYLINDERS.
Navigation
Issued 4 September 2000
Resolved
Inoperative Gyro Compass.
Fire Fighting
Issued 23 April 1999
Resolved
EMERGENCY FIRE PUMP HAD NO WATER PRESSURE. SOLAS 74 II-2 REG (4)
Documentation
Issued 8 October 1998
Resolved
PROVIDE FLAG STATE LICENSES FOR ALL OFFICERS OR PROVIDE LETTER FROM FLAG STATE ACCEPTING NON FLAG LICENSES NAMING COUNTRIES ACCEPTED._x001C_ STCW II/1, II/2, III/1, III/2.
Documentation
Issued 16 June 1995
Resolved
PROVIDE FIXED FIRE FIGHTING SYSTEM FOR THE CARGO HOLDS OR OBTAIN AN EXEMPTION CERTIFICATE PER SOLAS 60 II/65(f)(iii)
Fire Fighting
Issued 31 October 1992
Resolved
VSL'S FIRE HOSES WERE NOT ON STATION A VIOLATION OF SOLAS CH. II PART A REG. 4.7
Fire Fighting
Issued 31 October 1992
Resolved
VSL'S HOSE AT BRIDGE LEVEL HAS NO THREADED CURLING/LEAKS. A VIOLATION OF SOLAS PART A.
Fire Fighting
Issued 31 October 1992
Resolved
VSL'S EMERGENCY FIRE PUMP WAS INOPERATIVE.
Engineering
Issued 6 July 1988
Resolved
33CFR155.320(A)(2) THE VESSEL DID NOT HAVE FIXED CONTAINMENT OR AN ENCLOSEDDECK AREA UNDER OR AROUND ITS BULK LUBE OIL FILL PIPES AND VENT.
Documentation
Issued 6 July 1988
Resolved
33CFR155.450(A) THE VESSEL DID NOT HAVE THE REQUIRED POLLUTION PLACARD POSTED ON THE VESSEL.
Documentation
Issued 6 July 1988
Resolved
33CFR155.750 THE VESSEL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE. MISSING THE INFORMATION REQUIRED BY 33CFR155.750(A)(1)(I), (A)(2)(III), (A)(5), (A)(6), (A)(7), (A)(8) AND (A)(9).
Navigation
Issued 16 July 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE VSL DID NOT HAVE O/B U.S. CHART #12253, OR ITS FOREIGN EQUIV, WHICH WAS REQUIRED FOR THE VSL'S ROUTE FROM PORT NORFOLK REACH TO LONE STAR INDUSTRIES CEMENT WHARF, CHESAPEAKE, VA.
Navigation
Issued 16 July 1986
Resolved
A VIO OF 33 CFR 164.30 IN THAT THE U.S. COAST PILOT, VOL 3, USED BY THE VSLWAS NOT CORRECTED TO NTM 7/86, WHICH WAS REASONABLY AVAILABLE AND CONTAINEDCORRECTIONS THAT WERE APPLICABLE TO THE VSL'S ROUTE FROM VA CAPES TO LONESTAR INDUSTRIES CEMENT WHARF, CHESAPEAKE, VA.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.