Records from 1985 to 2004. Most recent: inspection, 24 November 2004.
Inspection history · 22
24 November 2004
ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 2248402
10 February 2003
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 1742666
16 April 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 289072
29 March 2000
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 276020
8 July 1997
Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 405327
15 October 1996
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 396425
9 March 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 710245
21 February 1995
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 375504
2 May 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 650203
22 April 1993
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 357717
17 October 1991
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 346596
3 April 1990
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 336234
20 November 1989
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 333785
18 May 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 330620
14 September 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 325993
13 July 1988
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 324325
29 December 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 320429
23 June 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 317034
16 March 1987
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 315474
13 November 1986
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 526789
4 June 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 302413
31 May 1985
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 302284
Lifesaving › Launching Appliances › Falls
Issued 24 November 2004
Resolved
Grease on fall lines are dry. Ensure fall lines are adequately greased.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 November 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 24 November 2004
No resolution recorded
Remove hazardous spliced wires from No.1 oiler cabin.
Action required: 15 - Rectify deficiencies by next port
Documentation › Manuals/Policy Documentation › Steering Gear Changeover Instructions
Issued 24 November 2004
No resolution recorded
Provide english or working crew translation for steering gear intructions for non-Korean speaking crew.
Action required: 15 - Rectify deficiencies by next port
Communications › Radio Communications › VHF Radiotelephone
Issued 24 November 2004
Resolved
Provide brow security with means to communicate with vessel security officer.
Action required: 15 - Rectify deficiencies by next port
Resolved 24 November 2004
Lifesaving › Immersion Suits › General
Issued 24 November 2004
No resolution recorded
Conduct required maintenance to immersion suites (Wax all immersion suit zippers for smooth operation, etc.).
Action required: 15 - Rectify deficiencies by next port
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 November 2004
No resolution recorded
Repair all 3 reefer door escape mechanisms to allow opening from within reefer in locked and unlocke condition.
Action required: 15 - Rectify deficiencies by next port
Construction/Loadline › Structures
Issued 10 February 2003
Resolved
Weathertight door leading to port lifeboat deck does not close properly. LEGACY COMPONENT DESC: Door
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 20 February 2003
Lifesaving › Lifeboat
Issued 10 February 2003
Resolved
Lifeboat grabrail on port lifeboat is wasted. LEGACY COMPONENT DESC: Handholds/Handrails
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 February 2003
Documentation › Safety/Response Plans/Programs
Issued 10 February 2003
Resolved
Vessel Shipboard Oil Pollution Emergency Plan (SOPEP) is expired. LEGACY COMPONENT DESC: SOPEP
Condition: Unknown
Due 10 May 2003
Resolved 12 February 2003
Lifesaving › Launching Appliances
Issued 10 February 2003
Resolved
Limit switch for the port lifeboat davit is inoperable. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Lifesaving › Launching Appliances
Issued 10 February 2003
Resolved
Limit switch for the starboard lifeboat davit is inoperable. LEGACY COMPONENT DESC: Davit
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Construction/Loadline › Markings
Issued 10 February 2003
Resolved
Loadline marks, reference mark, and draft marks are not contrasting colors. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 February 2003
Documentation › Logs/Records › Maneuvering Performance Test Results
Issued 10 February 2003
Resolved
Vessel does not have an International Rules of the Road. LEGACY COMPONENT DESC: International Rules of the Road
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 24 November 2004
Lifesaving › Lifebuoys
Issued 10 February 2003
Resolved
Staboard side lifebuoy on bridgewing is not quick-release arrangement. LEGACY COMPONENT DESC: Stowage
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2003
Operations/Management › Drills/Instruction
Issued 10 February 2003
Resolved
Fire fighting drill was inadequate. Crew failed fire fighting drill. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Operations/Management › Drills/Instruction
Issued 10 February 2003
Resolved
Lifeboat drill was inadequate. Crew failed abandon ship drill. LEGACY COMPONENT DESC: Abandon Ship
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2003
Navigation
Issued 29 March 2000
Resolved
Correct charts.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Unknown
Issued 29 March 2000
Resolved
Provide means of coms between bridge and steering flat.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Navigation
Issued 29 March 2000
Resolved
Install connector bolt in rudder angle arm linkage with the head up, not down.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 29 March 2000
Resolved
Remove gear and stores from emergency switch board room.
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 21 February 1995
Resolved
SMOKE FLOATS NOT MOUNTED TO RING BOUYS._x001C_ SOLAS CH III REG 7 (1)(3)._x001C_
Condition: Unknown
Due 22 February 1995
Resolved 7 March 1995
Documentation
Issued 21 February 1995
Resolved
OIL RECORD BOOK DOES NOT HAVE SIGNATURE AFTER EACH OPERATION.
Condition: Unknown
Due 22 February 1995
Resolved 7 March 1995
Documentation
Issued 21 February 1995
Resolved
VESSEL DOES NOT HAVE SAFE MANNING CERTIFICATE._x001C_ SOLAS CH V REG 13._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1995
Resolved 7 March 1995
Engineering
Issued 21 February 1995
Resolved
STARBOARD LUBE OIL VENT CONTAINMENT IS MISSING A WELD ARROUND THE VENT._x001C_ LUBE OIL FILL PIPE HAS NO CONTAINMENT.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Lifesaving
Issued 21 February 1995
Resolved
VESSEL MISSING TWO WATER LIGHTS FOR RING BOUYS (REQUIRES 4)._x001C_ SOLAS CH III REG 7 (1)(3)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1995
Resolved 7 March 1995
Documentation
Issued 21 February 1995
Resolved
2ND OFFICER LICENSE HAS MISSPELLED NAME.
Condition: Unknown
Due 15 October 1996
Resolved 15 October 1996
Navigation
Issued 21 February 1995
Resolved
LIGHT LIST NOT CURRENTLY CORRECTED
Condition: Unknown
Due 22 February 1995
Resolved 9 March 1995
Navigation
Issued 21 February 1995
Resolved
CHARTS NOT CORRECTED FOR AREA TRASITING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 February 1995
Resolved 9 March 1995
Navigation
Issued 22 April 1993
Resolved
CONDUCTED ANNUAL EXAM AND DISCREPANCY FOLLOW-UP AND FOUND VESSEL'S U.S.COAST PILOT OUTDATED(1988 EDITION WITH NO CORRECTIONS).
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Navigation
Issued 22 April 1993
Resolved
CONDUCTED ANNUAL EXAM, FOUND VESSEL CHARTS OUTDATED. LAST NTM CORRECTION 1987.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Navigation
Issued 17 October 1991
Resolved
BOARDING OFFICER EXAMINED TIDAL CURRENT TABLES ON BOARD AND FOUND NO 1991 EDITION.
Condition: Unknown
Due 3 May 1993
Resolved 2 May 1993
Navigation
Issued 17 October 1991
Resolved
BOARDING OFFICER ASKED CAPTAIN FOR A COPY OF THE LIGHT LIST. CAPTAIN STATED THAT A CURRENT COPY OF THE LIGHT LIST WAS NOT ON BOARD. AN OUTDATEDCOPY OF THE LIGHT LIST WAS FOUND FROM 1988.
Condition: Unknown
Due 3 May 1993
Resolved 2 May 1993
Navigation
Issued 17 October 1991
Resolved
BOARDING OFFICER EXAMINED COPIES OF TIDE TABLES ON BOARD AND FOUND NO 1991 EDITION.
Condition: Unknown
Due 3 May 1993
Resolved 2 May 1993
Navigation
Issued 17 October 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Documentation
Issued 18 May 1989
Resolved
THE VESSEL DID NOT HAVE THEIR CERTIFICATE OF FINANCIAL RESPONSIBILITY ON BOARD.
Condition: Unknown
Due 20 November 1989
Resolved 18 May 1989
Navigation
Issued 14 September 1988
Resolved
A VESSEL OF 1600 GROSS TONS MUST HAVE A CURRENTLY CORRECTED COAST PILOT ON BOARD.
Condition: Unknown
Due 20 November 1989
Resolved 14 September 1988
Navigation
Issued 14 September 1988
Resolved
A VESSEL OF 1600 GROSS TONS OR MORE MUST HAVE A CURRENTLY CORRECTED LIGHT LIST ON BOARD.
Condition: Unknown
Due 20 November 1989
Resolved 14 September 1988
Navigation
Issued 14 September 1988
Resolved
A VESSEL OF 1600 GROSS TONS OR MORE MUST HAVE A CURRENT YEAR TIDE TABLES ON BOARD.
Condition: Unknown
Due 20 November 1989
Resolved 14 September 1988
Navigation
Issued 14 September 1988
Resolved
A VESSEL OF 1600 GROSS TONS OR MORE MUST HAVE A CURRENT EDITION TIDE CURRENT TABLES ON BOARD.
Condition: Unknown
Due 20 November 1989
Resolved 14 September 1988
Construction/Loadline
Issued 14 September 1988
Resolved
NO FIXED CONTAINMENT OR ENCLOSED DECK AREA OF 1 BBL CAPACITY UNDER EACH LUBE OIL FILL PIPE AND TANK VENT.
Condition: Unknown
Due 20 November 1989
Resolved 14 September 1988
Navigation
Issued 29 December 1987
Resolved
33 CFR 164.33(A)(1)(II) VSL OVER 1600 GROSS TONS MUST HAVE LOCAL CHARTS THAT ARE CURRENTLY CORRECTED.
Condition: Unknown
Due 20 November 1989
Resolved 29 December 1987
Navigation
Issued 23 June 1987
Resolved
33 CFR 164.30 33 USC 1232 - $25,000. VESSEL CHART OF AREA OUTDATED WITH NO CORRECTIONS.
Condition: Unknown
Due 13 July 1988
Resolved 23 June 1987
Navigation
Issued 16 March 1987
Resolved
33CFR164.30,33USC1232,$25000. BOARDING OFFICER WAS INFORMED BY THE MASTER THAT THE CHART ONBOARD WAS DATED 1983 WITH NO CORRECTIONS MADE.
Condition: Unknown
Due 16 March 1987
Resolved 16 March 1987
Construction/Loadline
Issued 31 May 1985
Resolved
33 CFR 155.380(B) OILY-WATER SEPERATOR DISCHARGE ALARM SYSTEM
Condition: Unknown
Due 3 June 1985
Resolved 31 May 1985
Documentation
Issued 31 May 1985
Resolved
33 CFR 155.750 CONTENTS OF OIL TRANSFER PROCEDURES INCOMPLETE
Condition: Unknown
Due 3 June 1985
Resolved 31 May 1985