A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 31
27 January 2024
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7856660
21 July 2000
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1413778
20 March 1998
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113669
17 October 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 396358
17 October 1996
Control Verification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 847649
11 December 1995
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1419531
26 October 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 879086
25 October 1995
Administrative
Administrative · Marine Safety Center (MSC) · Activity 875334
23 October 1995
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 872148
6 June 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 379276
6 June 1995
MARPOL Annex V Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1355365
27 April 1995
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 377663
27 April 1995
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 925210
26 November 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1358227
17 November 1992
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1133062
27 October 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1250442
24 October 1992
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1257889
24 October 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1136486
19 October 1991
Certificate of Compliance
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 942691
19 October 1991
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1251469
8 January 1991
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 906549
23 May 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 330336
23 May 1989
Certificate of Compliance
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197660
23 June 1988
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 538337
11 April 1988
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1041884
20 October 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1017042
18 October 1987
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 319102
18 October 1987
Control Verification
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1015472
20 May 1986
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1297251
3 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 308638
11 April 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 301306
Electrical
Issued 21 July 2000
Resolved
PRIOR TO 04AUG00 INSTALL BLANKS IN OPENINGS IN ALL PANEL BOARDS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2000
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Construction/Loadline
Issued 21 July 2000
Resolved
PRIOR TO 04AUG00 CORRECT LOADLINE MARKINGS ON SIDE SHELL.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2000
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Lifesaving
Issued 21 July 2000
Resolved
PRIOR TO 04AUG00 REMOVE ALL MACHINERY SPARES FROM WIRE TRACKS IN E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2000
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Lifesaving
Issued 21 July 2000
Resolved
PRIOR TO 04AUG00 PROVIDE PROPOSAL FOR VENTING WASTE OIL TANK IN E/R.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 August 2000
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Separate fan room from workshop, deck 10 frame 57.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Install only furniture of restricted fire risk in purser's back offices with direct access to open information counter, SOLAS II-241-2.4.6
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Documentation
Issued 20 March 1998
Resolved
Update SOPEP and SOLAS training manuals with current ship's information.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Install remote indicator for fire screen door from galley to stair, deck 6 frame 52 starboard side, SOLAS II-2/41-2.4.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Complete installation of all smoke detectors listed on ship's memo dated 11March 1998, including public toilets, SOLAS II-2/41-2.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Install smoke detectors in 2 storerooms, deck 2 gymnasium, frames 102 and 119, SOLAS II-2/41-2.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Fire Fighting
Issued 20 March 1998
Resolved
Install lobby between stair and laundry, deck 2 frame 139, at least 9 square meters with a fire hose station, SOLAS II-2/41-2.4.5
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Accommodation/Occupational Safety
Issued 20 March 1998
Resolved
Modify air supply ducts to area above library glass bulkhead so that integrity of stairway A class boundary is not compromised.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Electrical
Issued 20 March 1998
Resolved
Install low location lighting on both sides of corridor over 2m wide, deck_x001C_11 frame 140, IMO A.752/4.2
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Electrical
Issued 20 March 1998
Resolved
Install vertical section of low location lighting to all pneumatic door controls. Relocate all low location lighting photoluminescent material that is hidden from light when the door is in its normal open position, IMOA.752/5.1 and 7.3
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 March 1998
Resolved 27 January 2024
Resolution: Due to age of open deficiencies, I have cleared them to clean up Sector Miami Open Deficiencies List.
Electrical
Issued 17 October 1996
Resolved
ELECTRICAL WIRING ON SHIPS FORWARD MAST IS NOT PROPERLY DEADENDED.
Condition: Unknown
Due 18 November 1996
Resolved 22 October 1996
Lifesaving
Issued 17 October 1996
Resolved
COMBUSTABLE MATERIAL IS BEING STORED IN THE SHIPS TRANSFORMER ROOM LOCATED ON THE STARBOARD SIDE ON THE COLUMBUS DECK.
Condition: Unknown
Due 18 November 1996
Resolved 22 October 1996
Lifesaving
Issued 17 October 1996
Resolved
GERNERAL ALARM SPEAKERS OUTSIDE CABINS 636 & 626 WERE INOPERABLE.
Condition: Unknown
Due 18 November 1996
Resolved 22 October 1996
Accommodation/Occupational Safety
Issued 17 October 1996
Resolved
EMPTY STATEROOMS ARE BEING USED FOR STORAGE, I.E., CLEANING GEAR, LINEN, TOWELS, ETC., WHICH INCREASES THE FIRE LOAD. ITEMS NEED TO BE REMOVED AND PROPERLY STORED.
Condition: Unknown
Due 18 November 1996
Resolved 22 October 1996
Accommodation/Occupational Safety
Issued 17 October 1996
Resolved
GALLEY STOREROOM (SPACE WHERE SPRINKLER TEST STATION FOR HARRY'S NEW YORK BAR IS LOCATED) NEEDS TO BE PROPERLY SECURED/STOWED. FALLING OBJECT, TRIPPING AND FIRE HAZARD.
Condition: Unknown
Due 18 November 1996
Resolved 22 October 1996
Lifesaving
Issued 23 October 1995
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED INBOARD RAILS ON LIFEBOATS 11 AND 12 IN WAY OF PREVENTER.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 23 October 1995
Resolved
RELABEL LIFEBOAT 4 WITH PROPER PERSON CAPACITY.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Fire Fighting
Issued 23 October 1995
Resolved
PERFORM FIRE DRILL TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Accommodation/Occupational Safety
Issued 23 October 1995
Resolved
REMOVE IMPROPER LINT TRAP FROM DRYER VENTS AND CLEAN LINT AND OTHER DEBRIS FROM REAR OF DRYERS.
Condition: Unknown
Due 23 October 1995
Resolved 31 October 1995
Lifesaving
Issued 23 October 1995
Resolved
PROVIDE CLASSIFICATION SOCIETY/FLAG STATE ADMINISTRATION ACCEPTANCE OR RECOMMENDATIONS FOR CORRECTION OF LIFERAFT STORAGE ARRANGEMENTS. LIFERAFTS CURRENTY STOWED AT 21 METERS ABOVE THE WATER. MANUFACTURER RECOMMENDS A STORAGE HEIGHT OF NOT MORE THAN 18 METERS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Lifesaving
Issued 23 October 1995
Resolved
REPLACE RING BUOYS IN LIFEBOATS 4 AND 6.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Fire Fighting
Issued 23 October 1995
Resolved
PROVE PROPER OPERATION OF FIRE DOOR INDICATOR PANEL ON BRIDGE.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 23 October 1995
Resolved
REPLACE MISSING CROSS FLOODING PANELS IN ENGINE ROOM.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Fire Fighting
Issued 23 October 1995
Resolved
RENEW VENTILATION AS DESIGNED AND PROVE PROPER OPERATION OF CO2 SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Accommodation/Occupational Safety
Issued 23 October 1995
Resolved
PROVIDE CLASSIFICATION SOCIETY/FLAG STATE ADMINISTRATION APPROVAL FOR ALL PLASTIC TRASH RECEPTACLES AS PER SOLAS 74 CHAPTER II-2, REG 18.5.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 23 October 1995
Resolved
PROVIDE ADDITIONAL LANTERNS FOR EMERGENCY GEAR LOCKERS 3 AND 4.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
CONDUCT A BOAT DRILL TO THE SATISFACTION OF AN ATTENDING COAST GUARD MARINEINSPECTOR.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Electrical
Issued 23 October 1995
Resolved
REPLACE LIGHT BULB IN EMREGENCY LIGHT FIXTURE IN POLLY VITAL CENTER.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Electrical
Issued 23 October 1995
Resolved
REPLACE THE LIGHT BULB IN SPACE H501F.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
REMOVE ALL FLAMMABLE MATERIALS IN FROM STAIRTOWER AND REMOVE ALL LINEN FROMSTORAGE OFF MAIN DINING ROOM.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
REPAIR #3 LIFEBOAT MASTHEAD LIGHT.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
REPAIR #12 LIFEBOAT MASTHEAD LIGHT.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
PROPERLY SECURE THE STARBOARD AFT SEAT IN THE #7 LIFEBOAT.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Lifesaving
Issued 23 October 1995
Resolved
REPLACE THE INTERNAL LIGHT BULB IN LIFEBOAT #5.
Condition: Unknown
Due 23 October 1995
Resolved 24 October 1995
Construction/Loadline
Issued 23 October 1995
Resolved
INSTALL METALLIC CLOSURE VALVE AT STEEL NIPPLE END OF PVC WATER LINE IN WAYOF WTD C202W IN SHIPS LAUNDRY ROOM.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 23 October 1995
Resolved
MAKE PERMANENT REPAIRS TO LIFEBOAT 9 HAND RELEASING GEAR.
Condition: Unknown
Due 4 November 1995
Resolved 4 December 1995
Fire Fighting
Issued 23 October 1995
Resolved
PROVIDE AND INSTALL LABELS FOR LOCATION OF CLOSURE DEVICES FOR FIRE SCREEN DOORS 400, 401 AND 402 LOCATED IN THE MAIN DINING ROOM.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Lifesaving
Issued 23 October 1995
Resolved
PROVIDE CLASS SOCIETY/FLAG STATE ADMINISTRATION ATTESTATION OF SATISFACTORYEMERGENCY EGRESS LABELS IN ALL PASSENGER STAIRWELLS.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Fire Fighting
Issued 26 November 1993
Resolved
PROVIDE DOCUMENTATION FROM FLAG ADMINISTRATION ACKNOWLEDGING/ACCEPTING THE FACT THAT HOSES IN INTERIOR LOCATIONS ARE NOT CONNECTED TO HYDRANTS AS REQUIRED BY SOLAS 74, CH II-2, REG 5(f).
Condition: Unknown
Due 14 December 1993
Resolved 14 December 1993
Construction/Loadline
Issued 27 October 1992
Resolved
MAKE PERMANENT REPAIRS TO THE OUTWARD MOST GLASS SHREADING SYSTEM OVERBOARDDISCHARGE VALVE. UNTIL SUCH TIME PERMANENT REPAIRS MADE, VOID SPACE MAN HOLE COCK VALVE IS TO BE MONITORED, WITH ANY WATER FOUND IN VOID SPACE IMMEDIATELY REMOVED.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Lifesaving
Issued 24 October 1992
Resolved
PROVIDE CERTIFICATION FROM VESSEL'S FLAG STATE ADMINISTRATION REGARDING WHETHER OR NOT LIFEJACKETS IN ADDITION TO THOSE LISTED ON THE PASSENGER SHIP SAFETY CERTIFICATE ARE REQUIRED FOR EACH LIFEBOAT WHEN OPERATED AS A LAUNCH TENDER.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 24 October 1992
Resolved
PROVIDE ONE - 12 MAN BUOYANT APPARATUS AS SPECIFIED IN PASSENGER SHIP SAFETY CERTIFICATE PRIOR TO DEPARTING THE PORT OF NEWPORT RI.
Condition: Unknown
Due 26 October 1992
Resolved 26 October 1992
Lifesaving
Issued 24 October 1992
Resolved
PROVIDE COPY OF REVISED PASSENGER SHIP SAFETY CERTIFICATE WITH REGARD TO THE NUMBER OF CHILDRENS LIFEJACKETS REQUIRED IN ACCORDANCE WITH PARAGRAPH AD 1 OF SEC-BERUFSGENOSSENSCHAFT LETTER DATED NOVEMBER 8, 1991.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Construction/Loadline
Issued 24 October 1992
Resolved
REMOVE OIL SLUDGE FROM VOID SPACE (LEERZELLE 30 SB) FRS 54-69 STBD AND MAKEAVAILABLE FOR COMPLETE EXAM. VERIFY CONDITION OF WIRING PASSING THRU VOID AND DETERMINE SOURCE OF LEAK. EFFECT PERMANENT REPAIRS TO THE SATISFACTION OF THE VESSEL'S CLASS SOCIETY AND/OR FLAG STATE ADMINISTRATION.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Lifesaving
Issued 19 October 1991
Resolved
THE VESSEL'S FOUR LAUNCHES MAY NOT BE USED TO CARRY PASSENGERS IN US WATERSUNTIL SUCH TIME AS THEY ARE ISSUED PASSENGER SHIP SAFETY CERTIFICATES BY THE FLAG STATE ADMINISTRATION AND A CONTROL VERIFICATION CERTIFICATE BY THEUS COAST GUARD.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION FROM THE VESSEL'S FLAG STATE ADMINISTRATION THAT THE MEANS OF ESCAPE FROM THE NIGHT CLUB (KAJUTE) ON THE 2ND DECK MEETS THE REQUIREMENTS OF SOLAS 74 CHAPT II-2, REGULATION 21 IN THAT THE DOOR LEADINGFROM THE NIGHT CLUB TO THE PANTRY IS CAPABLE OF BEING LOCKED.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
UPGRADE BOUNDARIES TO HARRY'S NY BAR TO MEET A-15 CLASS DIVISION IAW HAPAG-LLOYD KREUTZFAHRTEN FAX DTD 4SEP91. ADDITIONAL WATCHMAN FIRE PATROL SHALL BE MADE DURING THE 10 HRS/DAY WHEN THE AREA IS NOT MANNED BY THE SHIPS CREW, UNTIL THIS DEFICIENCIES IS SATISFIED.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION TO SHOW THAT THE GLASS PARTITION BULKHEADS SEPARATINGTHE MAIN STAIRWAYS FROM THE: LIBRARY, JEWELRY SHOP AND TOURIST OFFICE MEETTHE A-CLASS DIVISION REQUIREMENTS OF SOLAS 74 CHAPT II-2 REG 22 NOTE: THE TOURIST OFFICE, AND LIBRARY ARE NOT FITTED WITH AUTOMATIC SPRINKLERS.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Construction/Loadline
Issued 19 October 1991
Resolved
MAKE PERMANENT REPAIR TO AND PROVE PROPER OPERATION OF THE VESSEL'S SECOND WATERTIGHT DOOR HYDRAULIC PUMP.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION FROM THE VESSEL'S FLAG STATE ADMINISTRATION THAT THE GLASS PARTITION BULKHEAD PANELS SURROUNDING THE BOUTIQUE MEET B-15 CLASS DIVISION REQUIREMENTS OF SOLAS 74, CHAPT II-2, REGULATION 20.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION FROM THE VESSEL'S FLAG STATE ADMINISTRATION THAT THE SPRINKLER SYSTEM INSTALLED IN THE BOUTIQUE, JEWELRY SHOP & HARRY'S N.Y. BARMEET THE REQUIREMENTS OF SOLAS 74, CHAPT II-2 REGULATION 12 WITH REGARD TO AN INDEPENDENT SPRINKLER PUMP, PRESSURE TANK AND EMERGENCY SOURCE OF POWER.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION FROM THE VESSEL'S FLAG STATE ADMINISTRATION THAT THE NUMBER OF CHILDREN'S LIFE JACKETS (40) LISTED ON THE VESSEL'S PASSENGER SHIP'S SAFETY CERTIFICATE MEETS THE REQUIREMENTS OF SOLAS 74, CHAPT III, REGULATION 7.2.1.1
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Fire Fighting
Issued 19 October 1991
Resolved
PROVIDE DOCUMENTATION THAT THE VESSEL'S EIGHT FIRE SAFETY LINES FOR THE FIREMAN'S OUTFITS ARE FIREPROOF IN ACCORDANCE WITH SOLAS 74, CHAPT II-2, REGULATION 14.
Condition: Unknown
Due 19 October 1991
Resolved 19 October 1991
Lifesaving
Issued 18 October 1987
Resolved
CONDUCT FIRE AND LIFEBOAT DRILL TO COMPLETE CONTROL VERIFICATION.
Condition: Unknown
Due 18 October 1987
Resolved 18 October 1987