MAURY USCG vessel records Sign in
← All vessels

QUANTUM

QUANTUM is a 1980 freight ship. The Coast Guard has recorded 52 inspections since 1993, most recently in July 2008, along with 38 deficiencies — 1 with no resolution recorded — and 5 operational controls.

Records from 1993 to 2008. Most recent: operational control imposed, 17 July 2008.

Built
1980
Last inspected
17 July 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7831109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227743
Flag
PANAMA
—
Maury page id
psix-227743

Inspections, by type

…with no type recorded29
Years with a record 15 calendar years (1993–2008)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it4903 - Convention (Subpart B), Net Ton
9965 - Convention (Subpart B), Gross Ton
14550 - Dead Weight, Ton
20165 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

17 July 2008 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3270321
16 July 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3270044
3 July 2008 NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3256224
3 July 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3256409
12 June 2008 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3236080
7 June 2008 ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3223506
6 June 2008 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3228856
21 May 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2936509
20 May 2007 Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2935311
21 April 2006 PII Safety Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2630567
17 April 2006 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2619247
17 April 2006 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2619252
7 March 2006 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2597700
7 December 2005 ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2547842
23 May 2005 PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2365968
19 May 2005 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2362548
18 May 2005 Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2353979
10 May 2005 Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2353983
30 November 2004 PII Safety Exam
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2250314
16 August 2004 ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2168018
20 May 2004 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2073065
10 May 2004 Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2063681
22 September 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1910719
15 May 2003 Administrative Inspection · MARPOL Annex I Examination · Security Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1794268
15 April 2003 Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1771577
6 November 2002 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1701757
27 August 2002 Security Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1666978
27 August 2002 Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1667555
20 August 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1662551
27 September 2001 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 293683
8 September 2001 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 293486
29 August 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 293141
23 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 291655
7 September 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 438780
13 May 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 428570
3 May 1999 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 428102
28 April 1999 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 427924
10 September 1998 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 419981
6 July 1998 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 417544
11 October 1997 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 408995
7 August 1997 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 406447
28 April 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 402973
12 February 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400365
15 August 1996 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 394231
12 August 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 394210
6 May 1996 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 390554
26 April 1996 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 390619
21 April 1996 Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 390223
27 August 1995 Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 382143
18 May 1995 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 378323
6 September 1994 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 369583
3 November 1993 Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 362132

Deficiency record · 38

Electrical › Electric Generation Source (service) › Generator
Issued 17 July 2008 Resolved
Vessel's 3 ship service generators are inoperative, due to failure of air control system, and unable to provide power to the vessel's vital systems including fire pumps, propulsion auxiliaries, steering and additional essential systems. Vessel crew is unfamiliar with means to identify needed repair. Class to attest to proper operation of Generators and associated systems. 74 Solas(04) I/11 & XI-1/
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to proper operation of #2 and #3 SSDGs. Attending USCG PSCO observed proper operation of both SSDGs while #2 carried the ship''s load, paralleled, and while SSDG #3 carried the load.
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 July 2008 Resolved
Emergency generator is inoperable. Prior to overheating and subsequent failure, PSCO's observed a lube oil leak of approx. 1 gallon per minute, white smoke from exhaust piping, and gushing water from cooling system. Class to attest to the proper operation of the Emer. Generator. 74 Solas II-1/26(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to proper operation of EDG. Attending USCG PSCO observed proper operation of EDG while carrying a 15 kw load. Condition of Class issued for 30 days for minor exhaust leak.
Construction/Loadline › Structures › Superstructure
Issued 17 July 2008 Resolved
The "A" class fire division located between the paint locker and ship storage space(forward, portside) was found to be wasted, including an 18 X 2 hole. As a result of this wastage the installed CO2 system for the paint locker is ineffective. Repairs to class. 74 Solas(04 Cons.) II-2/14.2.1.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2008
Resolution: Received class report attesting to the repairs made and the integrity of the "A" class fire division. PSCO attended vessel and found repairs to be satisfactory.
Lifesaving › Lifeboat › Propulsion Engine
Issued 17 July 2008 Resolved
Vessel is equipped with 2 motor lifeboats. The portside lifeboat engine is inoperative leaving this lifeboat with only one means of propulsion (oars). Class to attest to proper operation of this lifeboat's engine prior to departure. 74SOLAS(2004cons.)III/20.2(all ships)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to proper operation of port lifeboat motor. Attending USCG PSCO observed proper operation while engaged forward and reverse.
Lifesaving › Lifeboat › Watertight Enclosure
Issued 17 July 2008 Resolved
The floating ball valves and boat plugs on both lifeboats were found to be seized and corroded affecting the watertight integrity of the boats. Make proper repairs to secure watertight integrity of the lifeboats to the satisfaction of class prior to departure. 74SOLAS(2004cons.)III/20.2(all ships)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to proper operation of plus and valves. Attending USCG PSCO observed proper operation and watertight integrity.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 July 2008 Resolved
Six portable fire extinguishers were found on station with cracked and wasted hoses. As well as under pressure affecting vessel's ability to adequately fight fire. Make repairs or replace these extinguishers. Class to attest to operational readiness prior to departure. 74SOLAS(2004cons.)II-2/14
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to replacement of 5 extinguishers and recharge for 1 extinguisher.
Fire Fighting › Firemans Outfit › Axe
Issued 17 July 2008 Resolved
Vessel's crew fabricated a replacement fire axe to meet requirements of the fire control plan. This axe located on the main deck, aft, port side was found with a handle that does not proved high-voltage insulation/protection. Provide protection as required or replace, so as to meet fire control plan, to the satisfaction of class prior to departure. 74SOLAS(2004cons.)II-2/10 FSS Code 3.2.1.1.5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to replacement of fire axe. Attending USCG PSCO found all as required.
Fire Fighting › International Shore Connection › Connection
Issued 17 July 2008 Resolved
Vessel’s international shore connection, stored aft, was found to be missing a gasket, two bolts and four washers. Provide required equipment prior to departure to the satisfaction of class. 74SOLASII-2/5(h)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to proper installation of international shore connection equipment. Attending USCG PSCO found all as required.
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 17 July 2008 Resolved
The "A" class fire division, located overhead of the steering gear/ emergency generator passageway, was found to be wasted and holed. Class to attest to proper repairs and integrity of "A" class fire division prior to departure. 74SOLAS(2004cons.) II-2/14.2.1.1.1(all ships)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2008
Resolution: Received class report attesting to the repairs made and the integrity of the "A" class fire division. PSCO attended vessel and found repairs to be satisfactory.
Fire Fighting › Fire Hoses › Condition
Issued 17 July 2008 Resolved
Four hoses, on reels, for the engine room's installed foam extinguishing system were found to be cracked, crimped and dry rotted. Make repairs or replace to the satisfaction of class prior to departure.74SOLAS(2004cons.)II-2/14
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to replacement of hoses. Attending USCG PSCO found that five hoses had been replaced as required.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 17 July 2008 Resolved
The vessel's sauna and surrounding area are being utilized for storage of paint, wood and other combustibles presenting clear risk of fire. vessel to take immediate action to clean this space of hazards to the satisfaction of class and USCG prior to departure. 74SOLAS(2004cons.) I/II
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to cleanliness of space and surrounding area to include removal of pain, wood, and other combustibles presenting risk of fire. Attending USCG PSCO found as required.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 July 2008 No resolution recorded
Several hydraulic leaks noted on deck and in pump space specifically associated with he cargo hatch securing system. Leaks were specifically noted in way of controller box hold #6 port side, ram hold #5 stbd forward part, controller box hold #4 port side, ram hold #2 port Foard part and the controller box for hatches 4, 5 & 6. Make repairs to the satisfaction of class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 July 2008 Resolved
The area under the hydraulic control pump for cargo hold hatch covers 4,5 &6 was found with approx. four gallons of standing hydraulic oil presenting risk of fire. Vessel to take immediate action to clean this space of oil and hazards to the satisfaction of class and USCG prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 July 2008
Resolution: Received class report attesting to removal of hydraulic oil and cleanliness of space.
Lifesaving › Immersion Suits › Marking
Issued 17 July 2008 Resolved
The stowage location for the immersion suits on the bridge are not clearly marked with the required IMO placards. Mark to the satisfaction of class. 74SOLAS(2004cons.) III/20.10
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 July 2008
Resolution: Received class report attesting to proper marking of immersion suits (bridge) stowage location with IMO placard.
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 17 July 2008 Resolved
The "A" class longitudinal fire division, located between the galley and battery room (aft, stbd. side) was found to be wasted and holed. Class to attest to proper repairs and integrity of "A" class fire division prior to departure. 74SOLAS(2004cons.) II-2/14.2.1.1.1(all ships)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 July 2008
Resolution: Received class report attesting to the repairs made and the integrity of the "A" class fire division. PSCO attended vessel and found repairs to be satisfactory.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 July 2008 Resolved
Upon Inspection of the OWS, C/E could not operate OWS. Pump For OWS is working but is not taking suction from the bilge holding tank. Vsl to properly repair OWS to the satisfaction of the flag.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2008
Resolution: Russian Maritime class report attests to proper working order of OWS. PSC Team verified proper working order of OWS with a successful 30 minute test of OWS.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 July 2008 Resolved
Oil residue found in Aft peak tank, #1 & #2 Ballast Pump piping systems, indicating oil has been discharged overboard. Flag to Determine source of oil into ballast tanks and system to provide corrective action addressing measures to clean contaminated ballast tank and associated piping and pumps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2008
Resolution: Flag report attests to improper use of aft peak tank by vessel. Class report attests that aft peaktank is completely sealed and associated bilge/ballast piping is removed. Aft peak tank to be effectively cleaned at dry dock scheduled for Oct 08.
Documentation › Logs/Records › Oil Record Book
Issued 3 July 2008 Resolved
Upon inspection of oil record book, found numerous discrepancies in reported bilge holding tank levels over the past two months.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2008
Resolution: Class attests that errors were made in ORB and company does not have a formal process to review entries.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 3 July 2008 Resolved
CH. ENG. was unable to articulate an understanding of the vessel's SMS. There is no preventative maintenance schedule onboard the vessel. there are no line or piping diagrams for vessel’s vital systems onboard. Captain was unable to provide a non- conformity report to company notifying of contamination in aft peak tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2008
Resolved 16 July 2008
Resolution: Class attests that vessel was found to be reporting defects but in daily messages and records were not being kept in a separate file. Class issued non-conformity for Master not reporting aft peak contamination and capped rubber hose in sounding tube.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 3 July 2008 Resolved
Ballast water reporting forms do not reflect the ballast water exchanges that were recorded in the ship's log book over the past two months.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2008
Resolved 16 July 2008
Resolution: Class acknowleges BW reporting errors in Class report and entry for the last ballast exchange has been changed to reflect the position of the vessel as per the official deck log book.
Operations/Management › Ballast Water Managment › Training
Issued 3 July 2008 Resolved
CH. Officer is unable to clearly articulate an understanding of the vessel's ballast water management plan. when asked about how often he takes soundings and conducts salinity checks, [name withheld] is not able to explain what is required as per vessel's BWM plan.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 July 2008
Resolved 16 July 2008
Resolution: C/O is removed and there is a new C/O onboard, who is familiar with BWM plan.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 3 July 2008 Resolved
Vessel failed to maintain the oil record book for the past three years.
Action required: 705 - Other - as specified
Due 4 July 2008
Resolved 16 July 2008
Resolution: Flag has attested in Flag report that the previous owners of the vessel did not release ORBs after releasing the vessel to the new/current owner. Flag acknowledges the ORB onboard starts on April 19, 2007 and no other ORBs are available.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 May 2007 Resolved
Vessel failed to provide inspection records for the fixed CO2 system. The most current record of inspection presented to CG inspectors was July 02, 1999. Vessel must have system inspected and the report of inspection approved by attending Classification Society.
Action required: 705 - Other - as specified
Due 21 May 2007
Resolved 22 May 2007
Resolution: Vessel had CO2 System inspected and class attested to the completion of the inspection.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 21 May 2007 Resolved
Vessel failed to provide inspection records for installed fixed Halon system. The crew stated that there was no halon inspections carried out since the vessel was purchased by current owners. Vessel must have system inspected and the report of inspection approved by attending Classification Society.
Action required: 705 - Other - as specified
Due 21 May 2007
Resolved 22 May 2007
Resolution: Vessel had Halon System inspected and class attested to the satisfactory inspection report.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 May 2007 Resolved
Vessel's MSD Type III holding tank is inoperable. The main holding tank has several holes and soft patches. Repair or renew sewage system.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 7 June 2008
Resolution: Vessel''s MSD Type III holding tank is now operational. The deficiency has been rectified.
Stability › Watertight Integrity › General
Issued 7 December 2005 Resolved
Code 1270, Description: Prove watertight doors to port fan space and to front of accommodation spaces are watertight to satisfaction of class. Provide proof of same to: Commanding Officer, USCG MSU Chicago prior to 18 December, 2005 Cite convention: SOLAS Reg 25-10(1) Action taken: a (to the satisfaction of class/RO/RSO)
Condition: Improper/Lack of Maintenance
Due 18 December 2005
Resolved 7 March 2006
Resolution: Recieved Class report attesting to the repairs of the watertight doors.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 23 May 2005 Resolved
Fuel oil leak on #1 generator on the #1 high pressure pump (SOLAS 60 11/343).
Action required: 15 - Rectify deficiencies by next port
Resolved 23 May 2005
Resolution: Corrected during the boarding.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 August 2004 Resolved
The No.2 generator has an excessive fuel oil leak on the No.1 high pressure fuel pump. Repair to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 23 May 2005
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 August 2004 Resolved
The No.2 generator exhaust flanges were smoking due to leaks from the fuel injector and rocker arm assembly area. Repair all leaks to the satisfaction of class.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2004
Resolved 23 May 2005
Lifesaving
Issued 23 June 2001 Resolved
VESSEL TO CONDUCT / FINISH REPAIRS TO STARBOARD SIDE LIFE BOAT AFT DAVIT._x001C_ (AFT DAVIT SEPARETED AT WELD) REPAIRS TO BE COMPLETED PRIOR TO NEXT US PORT, WITH CLASS SOCIETY SATISFACTION AND REPORT TO US COAST GUARD.
Condition: Unknown
Due 14 September 2001
Resolved 14 September 2001
Accommodation/Occupational Safety
Issued 3 May 1999 Resolved
LADDER FROM FORE DECK TO THE ANCHOR/LINE LOCKER STBD SIDE PARTED FROM THE BULKHEAD
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 3 May 1999 Resolved
STBD LIFE BOAT ENGINE WOULD NOT RUN, PORT SIDE LIFEBOAT SHAFT MOVES SLOW DUE TO IMPROPER MAINTENANCE
Condition: Unknown
Due 13 May 1999
Resolved 13 May 1999
Accommodation/Occupational Safety
Issued 3 May 1999 Resolved
ladder to the foremast(crowsnest) rusted through and broken.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Accommodation/Occupational Safety
Issued 3 May 1999 Resolved
STBD SIDE FORWARD LADDER, INBOARD HANDRAIL HAS DAMAGE FROM CARGO OFFLOADINGTHE HANDRAIL IS BENT OUT AT A 40 DEG. ANGLE AND HAS FRACTURES ALONG THE WELD.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Construction/Loadline
Issued 3 May 1999 Resolved
PORT SIDE FORWARD, BY HOLD #1 MOORING CHALK HAS THREE FRAMES FRACTURED AND PARTED FROM THE DECK. THE CORROSION DOES NOT PENETRATE THE MAIN DECK
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Lifesaving
Issued 28 April 1999 Resolved
Retro-reflective tape on starboard life boat was either missing or worn beyond it service life. Life boats are going to be serviced in May when vslis in dry dock.
Condition: Unknown
Due 14 July 1999
Resolved 14 July 1999
Navigation
Issued 6 July 1998 Resolved
Cotter pins missing on steering linkages.
Condition: Unknown
Due 6 July 1998
Resolved 7 July 1998
Engineering
Issued 21 April 1996 Resolved
F/O vent stbd side aft, near superstructure missing flamescreen.
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.