← All vessels
QUANTUM
Freight Ship · Bulk Carrier class · Built 1980s · USCG East District (CGD-E) · Other hulls named QUANTUM
QUANTUM is a 1980 freight ship. The Coast Guard has recorded 52 inspections since 1993, most recently in July 2008, along with 38 deficiencies — 1 with no resolution recorded — and 5 operational controls.
Records from 1993 to 2008. Most recent: operational control imposed, 17 July 2008.
- Built
- 1980
- Last inspected
- 17 July 2008
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 38 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7831109 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EKC4
227743
Flag
PANAMA
—
Maury page id
psix-227743
Inspections, by type
…with no type recorded29
Years with a record
15 calendar years (1993–2008)
The 52 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it4903 - Convention (Subpart B), Net Ton
9965 - Convention (Subpart B), Gross Ton
14550 - Dead Weight, Ton
20165 - Displacement, Ton
9965 - Convention (Subpart B), Gross Ton
14550 - Dead Weight, Ton
20165 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 52
17 July 2008
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3270321
16 July 2008
ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3270044
3 July 2008
NPV Safety Exam · MARPOL Annex I Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3256224
3 July 2008
Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3256409
12 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3236080
7 June 2008
ISPS II Exam · Deficiency Check · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3223506
6 June 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3228856
21 May 2007
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2936509
20 May 2007
Type not recorded
No type recorded · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2935311
21 April 2006
PII Safety Exam
Physical examination · Sector Lake Michigan · USCG Great Lakes District (CGD-GL) · Activity 2630567
17 April 2006
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2619247
17 April 2006
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2619252
7 March 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2597700
7 December 2005
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2547842
23 May 2005
PII Safety Exam
Physical examination · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 2365968
19 May 2005
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2362548
18 May 2005
Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2353979
10 May 2005
Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2353983
30 November 2004
PII Safety Exam
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2250314
16 August 2004
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2168018
20 May 2004
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2073065
10 May 2004
Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 2063681
22 September 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1910719
15 May 2003
Administrative Inspection · MARPOL Annex I Examination · Security Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1794268
15 April 2003
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1771577
6 November 2002
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1701757
27 August 2002
Security Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1666978
27 August 2002
Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1667555
20 August 2002
Passenger/Freight Vessel Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 1662551
27 September 2001
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 293683
8 September 2001
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 293486
29 August 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 293141
23 June 2001
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 291655
7 September 1999
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 438780
13 May 1999
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 428570
3 May 1999
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 428102
28 April 1999
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 427924
10 September 1998
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 419981
6 July 1998
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 417544
11 October 1997
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 408995
7 August 1997
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 406447
28 April 1997
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 402973
12 February 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 400365
15 August 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 394231
12 August 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 394210
6 May 1996
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 390554
26 April 1996
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 390619
21 April 1996
Type not recorded
No type recorded · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 390223
27 August 1995
Type not recorded
No type recorded · Marine Safety Unit Toledo · USCG Great Lakes District (CGD-GL) · Activity 382143
18 May 1995
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 378323
6 September 1994
Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 369583
3 November 1993
Type not recorded
No type recorded · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 362132
Deficiency record · 38
Electrical › Electric Generation Source (service) › Generator
Issued 17 July 2008
Resolved
Vessel's 3 ship service generators are inoperative, due to failure of air control system, and unable to provide power to the vessel's vital systems including fire pumps, propulsion auxiliaries, steering and additional essential systems. Vessel crew is unfamiliar with means to identify needed repair. Class to attest to proper operation of Generators and associated systems. 74 Solas(04) I/11 & XI-1/
Electrical › Electric Generation Source (emergency) › Generator
Issued 17 July 2008
Resolved
Emergency generator is inoperable. Prior to overheating and subsequent failure, PSCO's observed a lube oil leak of approx. 1 gallon per minute, white smoke from exhaust piping, and gushing water from cooling system. Class to attest to the proper operation of the Emer. Generator. 74 Solas II-1/26(a)
Construction/Loadline › Structures › Superstructure
Issued 17 July 2008
Resolved
The "A" class fire division located between the paint locker and ship storage space(forward, portside) was found to be wasted, including an 18 X 2 hole. As a result of this wastage the installed CO2 system for the paint locker is ineffective. Repairs to class. 74 Solas(04 Cons.) II-2/14.2.1.1.1
Lifesaving › Lifeboat › Propulsion Engine
Issued 17 July 2008
Resolved
Vessel is equipped with 2 motor lifeboats. The portside lifeboat engine is inoperative leaving this lifeboat with only one means of propulsion (oars). Class to attest to proper operation of this lifeboat's engine prior to departure. 74SOLAS(2004cons.)III/20.2(all ships)
Lifesaving › Lifeboat › Watertight Enclosure
Issued 17 July 2008
Resolved
The floating ball valves and boat plugs on both lifeboats were found to be seized and corroded affecting the watertight integrity of the boats. Make proper repairs to secure watertight integrity of the lifeboats to the satisfaction of class prior to departure. 74SOLAS(2004cons.)III/20.2(all ships)
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 July 2008
Resolved
Six portable fire extinguishers were found on station with cracked and wasted hoses. As well as under pressure affecting vessel's ability to adequately fight fire. Make repairs or replace these extinguishers. Class to attest to operational readiness prior to departure. 74SOLAS(2004cons.)II-2/14
Fire Fighting › Firemans Outfit › Axe
Issued 17 July 2008
Resolved
Vessel's crew fabricated a replacement fire axe to meet requirements of the fire control plan. This axe located on the main deck, aft, port side was found with a handle that does not proved high-voltage insulation/protection. Provide protection as required or replace, so as to meet fire control plan, to the satisfaction of class prior to departure. 74SOLAS(2004cons.)II-2/10 FSS Code 3.2.1.1.5
Fire Fighting › International Shore Connection › Connection
Issued 17 July 2008
Resolved
Vessel’s international shore connection, stored aft, was found to be missing a gasket, two bolts and four washers. Provide required equipment prior to departure to the satisfaction of class. 74SOLASII-2/5(h)
Fire Fighting › Structural - A Class Divisions › Corridors
Issued 17 July 2008
Resolved
The "A" class fire division, located overhead of the steering gear/ emergency generator passageway, was found to be wasted and holed. Class to attest to proper repairs and integrity of "A" class fire division prior to departure. 74SOLAS(2004cons.) II-2/14.2.1.1.1(all ships)
Fire Fighting › Fire Hoses › Condition
Issued 17 July 2008
Resolved
Four hoses, on reels, for the engine room's installed foam extinguishing system were found to be cracked, crimped and dry rotted. Make repairs or replace to the satisfaction of class prior to departure.74SOLAS(2004cons.)II-2/14
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 17 July 2008
Resolved
The vessel's sauna and surrounding area are being utilized for storage of paint, wood and other combustibles presenting clear risk of fire. vessel to take immediate action to clean this space of hazards to the satisfaction of class and USCG prior to departure. 74SOLAS(2004cons.) I/II
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 July 2008
No resolution recorded
Several hydraulic leaks noted on deck and in pump space specifically associated with he cargo hatch securing system. Leaks were specifically noted in way of controller box hold #6 port side, ram hold #5 stbd forward part, controller box hold #4 port side, ram hold #2 port Foard part and the controller box for hatches 4, 5 & 6. Make repairs to the satisfaction of class.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 July 2008
Resolved
The area under the hydraulic control pump for cargo hold hatch covers 4,5 &6 was found with approx. four gallons of standing hydraulic oil presenting risk of fire. Vessel to take immediate action to clean this space of oil and hazards to the satisfaction of class and USCG prior to departure.
Lifesaving › Immersion Suits › Marking
Issued 17 July 2008
Resolved
The stowage location for the immersion suits on the bridge are not clearly marked with the required IMO placards. Mark to the satisfaction of class. 74SOLAS(2004cons.) III/20.10
Fire Fighting › Structural - A Class Divisions › Aux Spaces (moderate fire risk)
Issued 17 July 2008
Resolved
The "A" class longitudinal fire division, located between the galley and battery room (aft, stbd. side) was found to be wasted and holed. Class to attest to proper repairs and integrity of "A" class fire division prior to departure. 74SOLAS(2004cons.) II-2/14.2.1.1.1(all ships)
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 3 July 2008
Resolved
Upon Inspection of the OWS, C/E could not operate OWS. Pump For OWS is working but is not taking suction from the bilge holding tank. Vsl to properly repair OWS to the satisfaction of the flag.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 July 2008
Resolved
Oil residue found in Aft peak tank, #1 & #2 Ballast Pump piping systems, indicating oil has been discharged overboard. Flag to Determine source of oil into ballast tanks and system to provide corrective action addressing measures to clean contaminated ballast tank and associated piping and pumps.
Documentation › Logs/Records › Oil Record Book
Issued 3 July 2008
Resolved
Upon inspection of oil record book, found numerous discrepancies in reported bilge holding tank levels over the past two months.
Documentation › Safety Management System › Reports and Analysis Procedures
Issued 3 July 2008
Resolved
CH. ENG. was unable to articulate an understanding of the vessel's SMS. There is no preventative maintenance schedule onboard the vessel. there are no line or piping diagrams for vessel’s vital systems onboard. Captain was unable to provide a non- conformity report to company notifying of contamination in aft peak tank.
Operations/Management › Ballast Water Managment › Submission of Report
Issued 3 July 2008
Resolved
Ballast water reporting forms do not reflect the ballast water exchanges that were recorded in the ship's log book over the past two months.
Operations/Management › Ballast Water Managment › Training
Issued 3 July 2008
Resolved
CH. Officer is unable to clearly articulate an understanding of the vessel's ballast water management plan. when asked about how often he takes soundings and conducts salinity checks, [name withheld] is not able to explain what is required as per vessel's BWM plan.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 3 July 2008
Resolved
Vessel failed to maintain the oil record book for the past three years.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 21 May 2007
Resolved
Vessel failed to provide inspection records for the fixed CO2 system. The most current record of inspection presented to CG inspectors was July 02, 1999. Vessel must have system inspected and the report of inspection approved by attending Classification Society.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 21 May 2007
Resolved
Vessel failed to provide inspection records for installed fixed Halon system. The crew stated that there was no halon inspections carried out since the vessel was purchased by current owners. Vessel must have system inspected and the report of inspection approved by attending Classification Society.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 May 2007
Resolved
Vessel's MSD Type III holding tank is inoperable. The main holding tank has several holes and soft patches. Repair or renew sewage system.
Stability › Watertight Integrity › General
Issued 7 December 2005
Resolved
Code 1270, Description: Prove watertight doors to port fan space and to front of accommodation spaces are watertight to satisfaction of class. Provide proof of same to: Commanding Officer, USCG MSU Chicago prior to 18 December, 2005
Cite convention: SOLAS Reg 25-10(1) Action taken: a (to the satisfaction of class/RO/RSO)
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 23 May 2005
Resolved
Fuel oil leak on #1 generator on the #1 high pressure pump (SOLAS 60 11/343).
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 16 August 2004
Resolved
The No.2 generator has an excessive fuel oil leak on the No.1 high pressure fuel pump. Repair to the satisfaction of class.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 16 August 2004
Resolved
The No.2 generator exhaust flanges were smoking due to leaks from the fuel injector and rocker arm assembly area. Repair all leaks to the satisfaction of class.
Lifesaving
Issued 23 June 2001
Resolved
VESSEL TO CONDUCT / FINISH REPAIRS TO STARBOARD SIDE LIFE BOAT AFT DAVIT._x001C_ (AFT DAVIT SEPARETED AT WELD) REPAIRS TO BE COMPLETED PRIOR TO NEXT US PORT, WITH CLASS SOCIETY SATISFACTION AND REPORT TO US COAST GUARD.
Accommodation/Occupational Safety
Issued 3 May 1999
Resolved
LADDER FROM FORE DECK TO THE ANCHOR/LINE LOCKER STBD SIDE PARTED FROM THE BULKHEAD
Lifesaving
Issued 3 May 1999
Resolved
STBD LIFE BOAT ENGINE WOULD NOT RUN, PORT SIDE LIFEBOAT SHAFT MOVES SLOW DUE TO IMPROPER MAINTENANCE
Accommodation/Occupational Safety
Issued 3 May 1999
Resolved
ladder to the foremast(crowsnest) rusted through and broken.
Accommodation/Occupational Safety
Issued 3 May 1999
Resolved
STBD SIDE FORWARD LADDER, INBOARD HANDRAIL HAS DAMAGE FROM CARGO OFFLOADINGTHE HANDRAIL IS BENT OUT AT A 40 DEG. ANGLE AND HAS FRACTURES ALONG THE WELD.
Construction/Loadline
Issued 3 May 1999
Resolved
PORT SIDE FORWARD, BY HOLD #1 MOORING CHALK HAS THREE FRAMES FRACTURED AND PARTED FROM THE DECK. THE CORROSION DOES NOT PENETRATE THE MAIN DECK
Lifesaving
Issued 28 April 1999
Resolved
Retro-reflective tape on starboard life boat was either missing or worn beyond it service life. Life boats are going to be serviced in May when vslis in dry dock.
Navigation
Issued 6 July 1998
Resolved
Cotter pins missing on steering linkages.
Engineering
Issued 21 April 1996
Resolved
F/O vent stbd side aft, near superstructure missing flamescreen.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National