MAURY USCG vessel records Sign in
← All vessels

P&O NEDLLOYD NINA

P&O NEDLLOYD NINA is a 1980 freight ship. The Coast Guard has recorded 79 inspections since 1984, most recently in January 2006, along with 36 deficiencies and 6 operational controls.

Records from 1984 to 2006. Most recent: inspection, 26 January 2006.

Built
1980
Last inspected
26 January 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7900065 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227749
Flag
UNITED KINGDOM
—
Maury page id
psix-227749

Inspections, by type

…with no type recorded56
Years with a record 18 calendar years (1984–2006)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9363 - Regulatory (Subpart C or D), Net Ton
30452 - Dead Weight, Ton
39815 - Displacement, Ton
31207 - Regulatory (Subpart C or D), Gross Ton
31207 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 6

Inspection history · 79

26 January 2006 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2573708
25 July 2005 ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 2439777
13 May 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2357082
8 May 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2352133
5 April 2005 PII Safety Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2327234
16 July 2004 ISPS II Exam
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2135803
10 June 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2094141
1 April 2004 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2035898
21 February 2004 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2010796
9 December 2003 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1961401
6 November 2003 Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1943438
1 November 2003 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1940029
22 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1799270
21 May 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1798676
14 April 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1798510
10 April 2003 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1771531
5 April 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1768796
4 April 2003 Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1768321
21 January 2003 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1733313
7 December 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1715723
6 December 2002 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1715295
13 September 2002 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1675385
5 September 2002 Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1671013
31 January 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 713496
30 January 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 387301
28 November 1995 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 534834
28 November 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 713495
26 November 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 385225
29 September 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 383267
7 August 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 713497
3 August 1995 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 381186
17 November 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 372446
16 July 1994 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 368582
18 January 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 439393
18 January 1994 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646900
27 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 646895
13 September 1993 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 360835
7 September 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 360596
3 August 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 352324
6 July 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 529816
4 June 1992 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 155228
8 May 1992 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1262245
7 May 1992 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 441724
27 April 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 647305
26 October 1991 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 346779
21 October 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 481999
9 July 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 530404
6 June 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 344248
6 June 1991 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 929382
7 January 1991 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 446831
17 July 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 338331
24 May 1990 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1214193
5 October 1989 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1313171
5 September 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 332494
8 August 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 331874
11 July 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 526233
25 April 1989 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 330047
23 February 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 457301
24 October 1988 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889467
9 August 1988 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 324988
19 May 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 475309
19 May 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 887397
19 May 1988 Certificate of Compliance
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 890446
30 March 1988 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 322301
5 November 1987 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 319470
6 October 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321395
15 March 1987 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 538815
12 March 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 513636
29 September 1986 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313718
25 September 1986 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 311714
20 June 1986 Control Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1299553
19 June 1986 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1307117
15 October 1985 Control Verification
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 987976
20 September 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 449280
18 September 1985 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 304489
26 July 1985 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 531752
13 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983855
28 December 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 516164
26 November 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 443799

Deficiency record · 36

Navigation › Piloting/Steering › Gyro Compass
Issued 26 January 2006 Resolved
Gyro Compass missing according to technicians report.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2006
Resolution: Mounted Gyro on bridge and wired in power. Mounted Sep Amp and wired-up to gyro. Wired in AIS and both ARPA''s. Confirmed ARPA''s are following gyro correctly. Gyro settled and ready for normal operations.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 5 April 2005 Resolved
No lifejackets in engine control room.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 May 2005
Resolution: Satisfactory lifejackets provided in engine control room.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 5 April 2005 Resolved
No nonskid or handrails in Steering Gear Room
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 27 April 2005
Resolution: Classification Society verified proper repairs.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 April 2005 Resolved
Machinery space bilges, containments, and main engine casing are coated with oil.
Action required: 705 - Other - as specified
Due 11 April 2005
Resolved 27 April 2005
Resolution: Classification Society verified deficiency was corrected with satisfactory result on 04/27/05 as required. Confirmed by attending Coast Guard Inspector on 05/09/2005.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 5 April 2005 Resolved
#2 cylinder liner seal of main engine has water leak
Action required: 705 - Other - as specified
Due 18 April 2005
Resolved 27 April 2005
Resolution: Verified by Classification Society as having satisfactory repairs.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 5 April 2005 Resolved
Verify structural integrity of Sea Chest inlets
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 13 May 2005
Construction/Loadline › Structures › Deck Plating
Issued 5 April 2005 Resolved
Deck wastage under fresh water generator
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 8 May 2005
Resolution: [name withheld] attested to proper repair of wasted deck under the fresh water generator.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 5 April 2005 Resolved
Gray water inlet pipe to MSD has a temporary repair
Action required: 705 - Other - as specified
Due 4 May 2005
Resolved 8 May 2005
Resolution: Repairs verified as satisfactory by attending Coast Guard inspector.
Engineering › Fuel Oil Service System › Pump
Issued 5 April 2005 Resolved
Fuel oil leak on Main Engine fuel oil booster pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2005
Resolution: Received class report attesting to the proper operation of the pump. Pump was dismantled and fitted with a new seal, remounted and test run. No leaks found.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 5 April 2005 Resolved
Verify proper operation of steam heating system installed in the purifier sludge tanks
Action required: 705 - Other - as specified
Due 1 June 2005
Resolved 8 May 2005
Resolution: Classification Society cleared the condition of class and attested to the proper operation of the steam heating in the purifier Sludge Tank.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 5 April 2005 Resolved
Verify incinerator can burn sludge as per the IOPP certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2005
Resolution: Received class report attesting to an interim IOPP Certificate and form A was issued reflecting the removal of the incinerator''s means for the disposal of residues
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 April 2005 Resolved
Verify proper operation of Oily Water Separator. Noted excessive sludge in the O/B discharge pipe
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2005
Resolution: Received class report attesting to the proper operation of the Oily Water Separator.
Pollution Prevention/Response › Prevention Equipment
Issued 6 November 2003 Resolved
The MSD tank top and side were wasted. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 9 December 2003
Resolution: MSD side and top replaced.
Navigation › Piloting/Steering
Issued 6 December 2002 Resolved
Rudder Angle Indicator at main steering stand malfunctioning. Vessel has experienced two separate incidents in which the rudder was placed at 20 degrees starboard but indicator remain fixed at 10 degrees port while underway. LEGACY COMPONENT DESC: Rudder Angle Indicator
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 December 2002
Resolved 21 January 2003
Resolution: Recieved technician report attesting to repairs. New rudder indictor installed and operating satisfactorily.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 September 2002 Resolved
MISSING CO2 CYLINDER PINS. DEFICIENCY WAS CORRECTED AND CLEARED PRIOR TO DEPARTURE OF MI.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 5 September 2002
Resolution: VESSEL REPLACED ALL MISSING PINS TO SATISFACTION OF MI.
Navigation
Issued 30 January 1996 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITH MANUEVERING FACT SHEET MISSING WARNING STATEMENT AS REQUIRED BY 33 CFR 164.35(g)(7).
Condition: Unknown
Due 31 January 1996
Resolved 23 February 1996
Unknown
Issued 30 January 1996 Resolved
VESSEL FAILED TO NOTIFY COTP NEW YORK OF INOPERABLE SECONDARY RADAR AS REQUIRED BY 33 CFR 164.53(b).
Condition: Unknown
Due 31 January 1996
Resolved 23 February 1996
Documentation
Issued 30 January 1996 Resolved
VESSEL ENTERD THE PORT OF NEW YORK WITH CHIEFMATE, SECONDMATE AND THIRD MATE NOT PROPERLY TRAINED IN HAZARDOUS MATERIAL HANDLING AS REQUIRED BY 49 CFR 176.13(b).
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Documentation
Issued 26 November 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE WORD "POISON" FOR THECOMMODITY BEING OFFERED FOR TRANSPORTATION AS REQUIRED BY 49 CFR 176.30(a)(6). Ref: 49 CFR 172.203(m)(1)._x001C_ Product: DICHLOROANILINE UN1590 PGII 6.1
Condition: Unknown
Due 26 November 1995
Resolved 27 November 1995
Documentation
Issued 26 November 1995 Resolved
VESSEL'S SHIPPING PAPERS DID NOT CONTAIN THE WORDS "MARINE POLLUTANT" FOR THE COMMODITY BEING OFFERED FOR TRANSPORTATION AS REQUIRED BY 49 CFR 172.203(l)._x001C_ Product: DICHLOROANILINES UN1590 PGII 6.1
Condition: Unknown
Due 26 November 1995
Resolved 27 November 1995
Documentation
Issued 26 November 1995 Resolved
VESSEL'S SHIPPING PAPERS DID NOT CONTAIN THE WORDS "POISON" FOR THE COMMDITY BEING OFFERED FOR TRANSPORTATION AS REQUIRED BY 49 CFR 172.203(m)(1)._x001C_ Product: DICHLOROANILINES UN1590 PGII 6.1
Condition: Unknown
Due 26 November 1995
Resolved 27 November 1995
Documentation
Issued 26 November 1995 Resolved
VESSEL'S SHIPPING PAPERS DID NOT CONTAIN THE EMERGENCY RESPONSE TELEPHONE NUMBER AS REQUIRED BY 49 CFR 172.201(d).
Condition: Unknown
Due 26 November 1995
Resolved 4 December 1995
Documentation
Issued 26 November 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE EMERGENCY RESPONSE PHONE NUMBER LISTED FOR A REGULATED COMMODITY BEING CARRIED AS REQUIRED BY 49 CFR 176.30(a)(3).
Condition: Unknown
Due 26 November 1995
Resolved 4 December 1995
Documentation
Issued 26 November 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST DID NOT CONTAIN THE WORDS "MARINE POLLUTANT" FOR THE COMMDITY BEING OFFERED FOR TRANSPORTATION AS REQUIRED BY49 CFR 176.30(a)(6). Ref: 49 FR 172.203(l)._x001C_ Product: DICHLOROANILINES UN1590 PGII 6.1
Condition: Unknown
Due 26 November 1995
Resolved 27 November 1995
Navigation
Issued 29 September 1995 Resolved
MANEUVERING INFORMATION FACT SHEET DID NOT MEET THE REQUIREMENTS OF 33 CFR 164.35(g). (NO INFORMATION FOR NORMAL BALLAST CONDITION: 164.35(g)(6) AND THE NAME ON THE WARNING STATEMENT=INCORRECT AND NEEDS UPDATE TO MEET THE REQ'S OF 164.33(g)(7).
Condition: Unknown
Due 1 April 1996
Resolved 1 April 1996
Documentation
Issued 3 August 1995 Resolved
VESSEL ENTERED THE PORT OF NEW YORK WITHOUT AN APPROVAL LETTER FOR THE VESSEL'S S.O.P.E.P. AS REQUIRED BY 33 CFR 151.29.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Navigation
Issued 3 August 1995 Resolved
VESSEL ENTERED THE PORT OF NEW YORK BRITISH ADMIRALTY CHARTS# 3204, 3457 AND 3459 NOT CORRECTED UP TO DATE AS REQUIRED BY 33 CFR 164.33(b).
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Documentation
Issued 3 August 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST (DCM) DID NOT HAVE THE MASTER'S SIGNATUREAS REQUIRED BY 49 CFR 176.30.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Documentation
Issued 3 August 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST WAS NOT PREPARED IN ACCORDANCE WITH 49 CFR 176.30, IN THAT THE STOWAGE LOCATION FOR CONTAINERS HLCU 210857-8, NOSU2382028, NOSU 2381546, TRIU 3788389, AND TRIU 3129648 WAS MISSING.
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Documentation
Issued 3 August 1995 Resolved
VESSEL'S DANGEROUS CARGO MANIFEST LISTED AN IMPROPER SHIPPING NAME FOR A REGULATED COMMODITY BEING CARRIED AS REQUIRED BY 49 CFR 176.30(a)(3).
Condition: Unknown
Due 3 August 1995
Resolved 3 August 1995
Accommodation/Occupational Safety
Issued 3 August 1995 Resolved
THE LATCH ON THE INSIDE OF THE DRY STORES WAS MISSING AND THE ALARM WAS INOPERABLE. ILO-147.
Condition: Unknown
Due 29 September 1995
Resolved 29 September 1995
Documentation
Issued 7 September 1993 Resolved
THE VESSEL DID NOT HAVE PROPER SHIPPING NAME FOR THE CARGO AMMUNITION PRACTICE UN#0362.
Condition: Unknown
Due 7 September 1993
Resolved 7 September 1993
Documentation
Issued 7 September 1993 Resolved
THE DCM WAS MISSING THE DATE OF PREPERATION.
Condition: Unknown
Due 18 January 1994
Resolved 18 January 1994
Navigation
Issued 8 August 1989 Resolved
VESSEL DID NOT HAVE A INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 8 August 1989
Resolved 8 August 1989
Deck/Cargo
Issued 9 August 1988 Resolved
COMODITY LISTED AS EXPLOSIVE CLASS "C" ON DCM CARRYING CLASS "B" PLACARD.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Navigation
Issued 5 November 1987 Resolved
A VIO OF 33 CFR 164.30 IN THAT THE US COAST PILOT (VOL.3) DTD 1986 WAS NOT CURRENTLY CORRECTED VIA NTMS WHICH WAS REASONABLY AVAILABLE AND CONTAINED THE THAT WERE APPLICABLE FOR THE VSLS ROUTE FROM SMITH PT, VA TO BALTIMORE HBR. NO FOREIGN EQUIV O/B.
Condition: Unknown
Due 30 March 1988
Resolved 5 November 1987

Ownership record