MAURY USCG vessel records Sign in
← All vessels

ETERNAL MARINER

ETERNAL MARINER is a 1980 freight ship. The Coast Guard has recorded 45 inspections since 1985, most recently in December 2008, along with 26 deficiencies and 3 operational controls.

Records from 1985 to 2008. Most recent: operational control imposed, 13 December 2008.

Built
1980
Last inspected
13 December 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7902532 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227780
Flag
SOUTH KOREA
—
Maury page id
psix-227780

Inspections, by type

…with no type recorded33
Years with a record 23 calendar years (1985–2008)
The 45 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11663 - Regulatory (Subpart C or D), Net Ton
23107 - Regulatory (Subpart C or D), Gross Ton
10758 - Dead Weight, Ton
10758 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 45

13 December 2008 Ballast Water Examination · MARPOL Annex V Examination · PII Safety Exam · ISPS III Exam · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3376251
4 June 2008 MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3221271
28 December 2007 MARPOL Annex I Examination · MARPOL Annex V Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3119785
6 June 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2671900
3 October 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2506943
4 April 2005 PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2325249
22 September 2004 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2202029
27 February 2004 MARPOL Annex I Examination · Annual Inspection · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2014289
21 November 2003 Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1950352
11 July 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1842571
11 February 2003 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1743245
11 September 2002 Re-Inspection · Ballast Water Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1673827
11 February 2002 Annual Inspection · MARPOL Annex I Examination · Passenger/Freight Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1485725
30 April 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1725144
22 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 287453
22 October 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 433862
11 April 1999 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 427269
5 October 1998 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 420916
19 November 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 409793
18 May 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 403666
13 April 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 402437
5 October 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 395880
12 February 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 387897
8 July 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 380094
31 May 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 378624
16 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 104503
16 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 375388
16 February 1995 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1371003
31 May 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 367305
15 April 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 357634
20 May 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 677028
17 May 1992 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 350847
5 November 1991 Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 346941
5 May 1991 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 343565
19 November 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 498997
13 April 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 336466
14 September 1989 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 447403
21 March 1989 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 329128
12 July 1988 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 324407
11 January 1988 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 457335
28 June 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 495496
29 May 1987 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 316409
9 October 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 519722
7 April 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 307942
29 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 301154

Deficiency record · 26

Lifesaving › Launching Appliances › Release Mechanism
Issued 13 December 2008 Resolved
Port side life/rescue boat could not be launched or recovered quickly as required by SOLAS. Pneumatic motor could not produce sufficient torque needed to recover boat. Air line that runs from deck fitting to receiver, also shows signs of detioration. Forward davit hook that holds the cable housing in place could not release, making the boat unable to be lowered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 13 December 2008
Resolution: Crew repaired necessary elements and was able to raise and lower the boat two times to the satisfaction of the attending MI.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 November 2003 Resolved
remove plywood and dunnage from CO2 room. SOLAS 60 I/11.
Action required: 15 - Rectify deficiencies by next port
Due 27 February 2004
Resolved 27 February 2004
Resolution: Dunnage and plywood removed from CO2 room to satisfaction of USCG Inspector.
Lifesaving › Inflatable Liferafts
Issued 21 November 2003 Resolved
provide instructions on the inflatable liferaft cannister that match style of liferaft carried. LEGACY COMPONENT DESC: Container Marking
Action required: 15 - Rectify deficiencies by next port
Due 27 March 2004
Resolved 27 February 2004
Resolution: Class survey of Lifeasaving Inflatable Lliferafts were conducted and found to be in compliance with Class standards.
Engineering › Lubricating Oil Service System
Issued 21 November 2003 Resolved
provide oil fuel line protection in addition to the high-pressure lines recently changed to satisfaction of class. SOLAS 74 amd II/15.11.
Action required: 15 - Rectify deficiencies by next port
Due 27 February 2004
Resolved 27 February 2004
Resolution: Class surveyed high-pressure lines on oil service system and verified the lines comply with Class and SOLAS.
Engineering
Issued 22 October 1999 Resolved
Repair Steam Leak in upper deck passageway overhead, outside of galley prior to next U.S. port. SOLAS 60,chap.1,reg. 11
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Electrical
Issued 22 October 1999 Resolved
Check all emergency battery lights and replace bulbs as needed prior to next U.S. port. SOLAS 60, chap.II, reg.26.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Navigation
Issued 13 April 1997 Resolved
Make permanent repairs to the Echo Depth Sounder prior to return to a U. S.port. _x001C_ _x001C_ SOLAS 74 amd V/12.k
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Engineering
Issued 13 April 1997 Resolved
Make permanent repairs to the wasted & leaking cooling lines to the L/O heat exchanger (stbd, lower level) prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Electrical
Issued 13 April 1997 Resolved
Rewire the electrical controls and pump motors on the steering gear prior to return to a U. S. port. Wire penetrations have all been pulled and are loose. Some have been improperly secured with silicone. _x001C_ SOLAS 60 II/29
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Lifesaving
Issued 13 April 1997 Resolved
Repair the broken door handle to the deck CO2 space prior to return to a U.S. port. One side of the handle is fractured. _x001C_ _x001C_ SOLAS 60 II/58
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Lifesaving
Issued 13 April 1997 Resolved
Remove the barrel of oil in the stbd, fwd, lower level of the engineroom prior to return to a U. S. port. Barrel has an open top & is completely filled with oil for cleaning machinery. _x001C_ SOLAS 60 II/28
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Lifesaving
Issued 13 April 1997 Resolved
Clean the excessive oil from about the steering gear, generator diesel engine HP fuel pumps and the sides of the main engine. Provide a class report on the M/E leaks and repairs conducted to secure leaks prior to return to a U. S. port. SOLAS 60 II/28
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Engineering
Issued 13 April 1997 Resolved
Provide a class report on the condition of the wasted & patched OWS tanks. Make necessary repairs prior to return to a U. S. port as required by class._x001C_ MARPOL 73/78 I/16
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Engineering
Issued 13 April 1997 Resolved
Make permanent repairs to the wasted heat exchanger cooling pipe on the port diesel generator engine prior to return to a U. S. port. _x001C_ _x001C_ SOLAS 60 I/11
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Fire Fighting
Issued 13 April 1997 Resolved
Make repairs to the fire detector over the port auxiliary cooling pump and prove proper operation prior to return to a U. S. port. Detector is held in place with tape. _x001C_ SOLAS 60 II/54
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Electrical
Issued 13 April 1997 Resolved
Make permanent repairs or renew the electrical box on the port, lower level, aft purifier motor. Box is held together with electrical tape. Complete prior to return to a U. S. port._x001C_ SOLAS 60 II/27
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Electrical
Issued 13 April 1997 Resolved
Rewire the motor for the port auxiliary cooling pump motor prior to return to a U. S. port. Wires have been pulled from electrical box and are chaffing against the penetration. _x001C_ SOLAS 60 I/27
Condition: Unknown
Due 18 May 1997
Resolved 18 May 1997
Navigation
Issued 31 May 1995 Resolved
Clean up oil from under steering gear foundation prior to return to U. S. per SOLAS Chpt II-2 Reg 2(1)
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Fire Fighting
Issued 31 May 1995 Resolved
The emergency fire pump suction line (located in aft peak tank) has a hole wasted through, affecting the suction ability of the pump. This was temporarilly patched. Make permanent repairs prior to return to a U.S. port per SOLAS Chpt II-2 Reg 4. (KRS report of repairs should be provided)
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 31 May 1995 Resolved
Prove proper operation of emergency fire pump discharge without back flushing from main fire pumps. Provide a proper belt for the priming drive as the existing one is loose and falls off rollers. Remount guard over firepump belt drive. SOLAS Chpt. II-2 Reg. 4(3.3.2)
Condition: Unknown
Due 30 June 1995
Resolved 7 June 1995
Engineering
Issued 31 May 1995 Resolved
Clean up and repair the excessive oil leakage about the following: a) Both M/E lube oil pumps; b) Boiler burner assembly; c) Aft, lower level purifiervalves prior to return to U. S. per SOLAS Chpt II-2 Reg 2(1)._x001C_ (***Only item (a) remains outstanding***)_x001C_
Condition: Unknown
Due 17 July 1995
Resolved 17 July 1995
Fire Fighting
Issued 31 May 1995 Resolved
Repair the disabled fire door's closure devices and remove hold back hooks on all three fire doors to the steering gear space prior to departure per SOLAS Chpt II-2 Reg 47(2)
Condition: Unknown
Due 5 June 1995
Resolved 5 June 1995
Navigation
Issued 17 May 1992 Resolved
DURING THE COURSE OF A FOREIGN FREIGHT VESSEL EXAMINATION IT WAS DISCOVEREDTHAT THE M/V HYUNDAI NO.2 HAD ENTERED THE PORT OF LOS ANGELES WITHOUT AN INSTALLED ARPA AS REQUIRED BY 33 CFR 164.38(b)(3)(ii). THE MASTER STATED THAT THE ARPA WAS GOING TO BE INSTALLED DURING DRY DOCK IN JAPAN (NPC).
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Accommodation/Occupational Safety
Issued 29 May 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON, WITH ITS MARINE SANITATION DEVICE BYPASSED, ALLOWING DISCHARGE OF RAW SEWAGE INTO THE RIVER.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Navigation
Issued 29 May 1987 Resolved
VESSEL TRANSITED THE COLUMBIA RIVER TO PORTLAND, OREGON, WITHOUT HAVING A COPY OF THE INLAND NAVIGATION RULES.
Condition: Unknown
Due 29 May 1987
Resolved 29 May 1987
Navigation
Issued 7 April 1986 Resolved
NOS CHARTS 18720, 18740, 18746 & 18751 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 7 April 1986
Resolved 7 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.