MAURY USCG vessel records Sign in
← All vessels

EAGLE II

EAGLE II is a 1980 tank ship. The Coast Guard has recorded 27 inspections since 1984, most recently in March 2003, along with 40 deficiencies — 4 with no resolution recorded — and 3 operational controls, 2 with no removal date recorded.

Records from 1984 to 2003. Most recent: inspection, 24 March 2003.

Built
1980
Last inspected
24 March 2003
Documentation
Not in the documentation file of 10 September 2026
Controls
2 with no removal date recorded

Identity

7902582 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227785
Flag
PANAMA
—
Maury page id
psix-227785

Inspections, by type

…with no type recorded21
…past their stated due date3
Years with a record 12 calendar years (1984–2003)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 23 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it29547 - Regulatory (Subpart C or D), Net Ton
51723 - Regulatory (Subpart C or D), Gross Ton
97838 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

HEYDEN-BAMIDELE Tank Barge · MISLE 50201 · 30 January 1999 · activity 476762

Inspection history · 27

24 March 2003 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1762064
16 August 2002 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1660818
31 March 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 288605
9 April 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 276522
9 April 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1050972
17 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 724867
9 September 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 432569
9 July 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 195072
9 July 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 753907
30 January 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 476762
16 January 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 424662
16 January 1999 Tank Vessel Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129362
18 January 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 412149
4 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 407634
4 September 1997 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1123455
25 July 1997 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 406092
31 March 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 402140
22 November 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 397863
19 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 383166
18 September 1995 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 140528
9 March 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 483808
23 November 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 340512
23 November 1990 Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 912706
1 September 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 318201
1 September 1987 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310253
1 September 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310254
19 June 1984 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 296683

Deficiency record · 40

Deck/Cargo › Inert Gas System
Issued 16 August 2002 Resolved
COTP ORDER 029-02 reqd surveyor from vsl's class society to attend vsl and verify IGS and cargo pump leak have been repaired and operating properly and a copy of this rpt provided to COTP for approval prior to cargo transfer.Vsl restricted to anchorage or dock until rpts rcvd and order rescinded.
Action required: 705 - Other - as specified
Resolved 16 August 2002
Resolution: Item corrected.
Engineering › Steering Gear System › Ram Seal
Issued 16 August 2002 Resolved
No. 1-2 stg gear cylinders leaking. SOLAS Ch I Reg 11(a). Repair to satisfaction of class (ABS).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Engineering
Issued 16 August 2002 Resolved
Waste oil pump for incinerator does not operate properly. SOLAS Ch I Reg 11(a). Prove proper operation of incinerator to satisfaction of class (ABS) and attending USCG inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 August 2002 Resolved
In galley and accomodation spaces, checked several faucets. All contaminated with rust water. Ran tub in hospital 5 minutes with nothing but rust water coming out. ILO 147. Correct to satisfaction of class (ABS).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 August 2002 Resolved
Steam cargo pump has leaking seal. SOLAS Ch I Reg 11(a). Repair prior to cargo transfer operations. LEGACY COMPONENT DESC: Cargo Pump
Action required: 705 - Other - as specified
Resolved 18 August 2002
Resolution: Item corrected.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 16 August 2002 Resolved
Cargo residue present in pumproom. SOLAS Ch I Reg 11(a). Remove cargo residue prior to cargo operations. LEGACY COMPONENT DESC: Pumproom
Action required: 705 - Other - as specified
Resolved 18 August 2002
Resolution: Item corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 August 2002 No resolution recorded
Burnt out lighting in pumproom. ILO 147. Correct.
Action required: 705 - Other - as specified
Due 16 September 2002 — due date passed with no resolution recorded
Lifesaving › Lifeboat › Handholds/Handrails
Issued 16 August 2002 No resolution recorded
Stbd lifeboat bottom handrail has 2 holders deterioriated. LSA CH IV 4.4.7.4. Repair.
Action required: 705 - Other - as specified
Due 16 September 2002 — due date passed with no resolution recorded
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 August 2002 No resolution recorded
Box on stbd side for lifejackets and immersion suits not waterproof. SOLAS CH I Reg 11(a). Provide waterproofing so that lifejackets and immersion suits do not get wet.
Action required: 705 - Other - as specified
Due 16 September 2002 — due date passed with no resolution recorded
Engineering
Issued 16 August 2002 Resolved
F.O. leak in incinerator. SOLAS Ch I Reg 11(a). Repair to satisfaction of class (ABS).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Deck/Cargo › Inert Gas System
Issued 16 August 2002 Resolved
IGS mn ctrl valve and dk water seal not operating properly. SOLAS Ch I Reg 11(a) and 46 CFR 32.53-1. Repair and prove operation of entire IGS system to satisfaction of class (ABS). LEGACY COMPONENT DESC: Water Seal
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2002
Resolution: Item corrected.
Engineering
Issued 16 August 2002 Resolved
Repair and demonstrate operation of incinerator to satisfaction of class (ABS) and attending USCG inspector. SOLAS Ch I Reg 11(a).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 16 August 2002 Resolved
Prove proper operation of oily water separator to satisfaction of class (ABS) and attending USCG marine inspector. 33 CFR 155.380(b). LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Documentation › Safety Management System
Issued 16 August 2002 Resolved
Numerous deficiencies, master's unfamiliarity with SMS, and the absence of documentation which demonstrates the proper reporting of these non-conformities indicate the SMS has not been implemented properly. BV shall attend vsl and certify SMS is properly implemented and followed. SOLAS Ch IX. LEGACY COMPONENT DESC: Master''''''''''''''''s Authority/Responsibility Documentation
Action required: 705 - Other - as specified
Resolved 17 August 2002
Resolution: BV attended vsl and determine vsl had 1 major non-conformity and 3 non-conformities.
Personnel › Manning/Qualifications
Issued 16 August 2002 Resolved
After interview with several crew members and the Ch Engr, Ioannis Mpotonakis, PSCO determined that the Ch Engr is not competent in the use of English in oral form. Vsl reqd to have another licensed Ch Engr, who is competent in the use of English in oral form, on board. STCW 95 Table A-III/I.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 August 2002
Resolution: Item corrected.
Documentation › Logs/Records › Oil Record Book
Issued 16 August 2002 No resolution recorded
False entries in the Oil Record Book. 33 CFR 151.25(d) Vsl required to prove proper enteries are being made into the Oil Record Book at next U.S. port call.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Unknown
Issued 31 March 2001 Resolved
06 RATIONS FOUND TO BE BAD. SOLAS 74/78 CHIII REG 41.8.12. VESSEL CORRECTED PRIOR TO DEPARTURE.
Condition: Unknown
Due 31 March 2001
Resolved 2 April 2001
Deck/Cargo
Issued 9 April 2000 Resolved
CARGO PUMP ROOM; NO. 2 PUMP DISCHARGE GAUGE BROKEN; AND BALLAST PUMP SUCTION GAUGE BROKEN. REPAIR TO THE SATISFACTION OF USCG PRIOR TO 09MAY00.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Electrical
Issued 9 April 2000 Resolved
LIGHTS IN VARIOUS CREW'S CABINS ARE MISSING COVER, WIRES ARE EXPOSED. REPLACE COVERS ON ALL LIGHTS PRIOR TO 09MAY00.
Condition: Unknown
Due 9 May 2000
Resolved 15 May 2000
Fire Fighting
Issued 9 April 2000 Resolved
DOG MISSING FROM ACCOM. EXHAUST VENT FIRE DAMPNER (STBD SID I.W.O. LIFEBOAT) REPAIR/REPLACE MISSING DOG TO THE SATISFACTION OF CLASS PRIOR TO 09MAY00.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Deck/Cargo
Issued 9 April 2000 Resolved
COMBING I.W.O. PT/STBD SIDE (NO.1) CARGO TANK, HEIGHT IS APPROXIMATELY _x001C_ 3"X 20FT - NOT CORRECT SIZE. CORRECT DURING NEXT SCHEDULED DRYDOCK (JUL/00)
Condition: Unknown
Due 13 December 2000
Resolved 13 December 2000
Construction/Loadline
Issued 9 April 2000 Resolved
LOADLINE MARK IS NOT IN CONTRASTING COLOR TO THE VESSEL'S HULL. PAINT LOADLINE TO THE SATISFACTION OF CLASS PRIOR TO 23APR00.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Lifesaving
Issued 9 April 2000 Resolved
IN THE CARGO CONTROL ROOM, CONTROL PANEL IS MISSING BACK COVER-GEAR IS STOWED BEHIND PANEL; POSSIBLE SHOCK HAZARD. REMOVE GEAR FROM BEHIND PANEL, INSTALL COVERS TO PREVENT SHOCK PRIOR TO 09MAY00 TO SATISFACTION OF USCG.
Condition: Unknown
Due 25 April 2000
Resolved 25 April 2000
Lifesaving
Issued 9 September 1999 Resolved
EMERGENCY FIRE PUMP NOT AVAILABLE FOR IMMEDIATE USE_x001C_ ---SOLAS 74(AMENDED) II-2/21
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Lifesaving
Issued 9 September 1999 Resolved
FALLS ARE NOT END FOR ENDED WITHIN 30 MONTHS_x001C_ ---SOLAS 74 III/19.4---
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Navigation
Issued 9 September 1999 Resolved
VESSEL ENTERED THE PORT OF CORPUS CHRISTI WITHOUT AN ECHO DEPTH SOUNDER INSTALLED AND DID NOT NOTIFY THE LOCAL OCMI.
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Fire Fighting
Issued 9 September 1999 Resolved
DOG MISSING FROM GALLEY EXHAUST VENT FIRE DAMPER_x001C_ ---ILLC 66 ANNEX I/15---
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Unknown
Issued 9 September 1999 Resolved
LOAD LINE NOT PAINTED_x001C_ ---ILLC 66 ANNEX 119---
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Lifesaving
Issued 9 September 1999 Resolved
INFLATABLE LIFERAFT NOT SERVICED WITHIN ONE(1) YEAR_x001C_ ---SOLAS 74(AMENDED) III/19.8.1---
Condition: Unknown
Due 13 April 2000
Resolved 13 April 2000
Documentation
Issued 16 January 1999 Resolved
VESSEL DID NOT HAVE AN ENDORSEMENT ON ITS CRUDE OIL WASHING MANUAL.
Condition: Unknown
Due 18 January 1999
Resolved 19 January 1999
Navigation
Issued 16 January 1999 Resolved
THE SECONDARY RADAR WAS NOT WORKING PROPERLY. THE VESSEL WAS TO PROVIDE PROPER NOTIFICATION TO COTP LONG ISLAND SOUND OF THE FAULTY RADAR AND WAS GIVEN UNTIL 18JAN99 TO BE FIXED.
Condition: Unknown
Due 18 January 1999
Resolved 19 January 1999
Fire Fighting
Issued 16 January 1999 Resolved
HOLED FIREMAIN JUST FORWARD OF AFT FIRE MONITOR. VESSEL GIVEN UNTIL 18JAN99 TO MAKE MAKE PROPER REPAIRS AND PROVIDE A CLASS SOCIETY REPORT ATTESTING TO SATISFACTORY REPAIRS PRIOR TO CONDUCTING ANY CARGO OPERATIONS.
Condition: Unknown
Due 18 January 1999
Resolved 19 January 1999
Lifesaving
Issued 18 January 1998 Resolved
Prove proper operation of port and starboard lifeboat motors to the satisfaction of the class society prior to departing the harbor of New York, NY but not later than 27JAN98.
Condition: Unknown
Due 23 January 1998
Resolved 23 January 1998
Construction/Loadline
Issued 22 November 1996 Resolved
HAVE CLASS SOCIETY ATTEST TO THE NON-INSTALLATION OF A SPOOL PIECE IN THE PUMPROOM TO CONNECT THE CARGO LINE TO THE SEGREGATED BALLAST SYSTEM FOR EMERGENCY BALLASTING OPERATIONS PER MARPOL 73/78 ANNEX I REG 1(17). FAX SURVEY REPORT TO MSU GALVESTON.
Condition: Unknown
Due 31 March 1997
Resolved 31 March 1997
Navigation
Issued 23 November 1990 Resolved
VESSELS U.S. COAST PILOT VOL 7 AND U.S.C.G. LIGHT LIST VOL VI. WERE NOT CORRECTED TO DATE AS REQUIRED BY 33CFR164.33(a)(2)(i & ii).
Condition: Unknown
Due 23 November 1990
Resolved 23 November 1990
Navigation
Issued 23 November 1990 Resolved
VESSELS N.O.S. CHARTS 18720,18740,18749, & 18751 WERE NOT CORRECTED TO DATEAS REQUIRED BY 33CFR164.33(a)(1)(ii).
Condition: Unknown
Due 23 November 1990
Resolved 23 November 1990
Navigation
Issued 23 November 1990 Resolved
VESSEL DID NOT HAVE A COPY OF N.O.S. CHART 18746 OR A FOREIGN EQUIVELANT ONBOARD AS REQUIRED BY 33CFR164.33(a)(1) OR (b).
Condition: Unknown
Due 23 November 1990
Resolved 23 November 1990
Engineering
Issued 23 November 1990 Resolved
PROVE PROPER OPERATION OF THE OILY WATER SEPARATOR'S OIL CONTENT METER.
Condition: Unknown
Due 23 November 1990
Resolved 23 November 1990
Deck/Cargo
Issued 1 September 1987 Resolved
RECALIBRATE IGS GAS PRESSURE RECORDER PRIOR TO RETURNING TO U.S. PORT.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Deck/Cargo
Issued 19 June 1984 Resolved
46 CFR 35.30: FLAME SCREENS WERE WORN AND HAD PAINT ON THEM.
Condition: Unknown
Due 19 June 1984
Resolved 19 June 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.