The 3 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Share this recordDownload vessel cardDownload QRMaury, US Coast Guard vessel record for EGUZKIA, retrieved 18 September 2026. mauryrecords.com/v/psix-227813.html
Documentation record
Tonnage as PSIX records it708 - Regulatory (Subpart C or D), Net Ton 542 - Convention (Subpart B), Net Ton 2359 - Regulatory (Subpart C or D), Gross Ton 1203 - Convention (Subpart B), Gross Ton 2536 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 3
23 September 1996Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 395652
9 October 1992Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 353651
15 November 1988Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 326841
RENEW WEATHER TIGHT DOOR ON AIR CONDITION ROOM ENSURING WEATHER TIGHT SEAL.(ICLL 69 REG. 19 AND 20) PROVIDE/REPAIR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 23 September 1996Resolved
VESSEL MISSING VOLUME J LIGHT LIST. NO CURRENT EDITION ON BOARD. PROVIDE PRIOR TO NEXT U.S. PORT. (33 C.F.R. 164.33)
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 23 September 1996Resolved
VESSEL MISSING STANDARD DISCHARGE CONNECTION. PROVIDE PRIOR TO NEXT U.S. PORT. (MARPOL 73/78 ANNEX ONE REG. 19).
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 23 September 1996Resolved
PROVIDE APPROPRIATE HANDRAILS/CHAINS IN WAY OF PORT & STBD LIFERAFT STATIONS THAT WILL ENSURE SAFETY FOR CREW. (ICCL 69 REG. 25) PROVIDE TO THESATISFACTION OF CLASS SOCIETY WITH SURVEYOR'S REPORT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 23 September 1996Resolved
REPAIR HOLE IN EMERGENCY FIRE PUMP EXHAUST PIPING INSIDE STEERING GEAR COMPARTMENT. (ILO 147) REPAIR PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 23 September 1996Resolved
DEMONSTRATE PROPER OPERATION OF 15PPM ALARM ON OIL WATER SEPARATOR. (MARPOL73/78 ANNEX I REG.16) PROVIDE TO THE SATISFACTION OF CLASS SOCIETY. PROVIDELOCAL COAST GUARD WITH SATISFACTORY SURVEYOR'S REPORT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 23 September 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 9 October 1992Resolved
VSL'S OIL TRANSFER PROCEDURES WERE INCOMPLETE.
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Documentation
Issued 9 October 1992Resolved
VSL HAD NO OIL POLLUTION PLACARDS POSTED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 September 1996
Resolved 26 September 1996
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.