MONTHIRA NAREE

MONTHIRA NAREE is a 1980 freight ship. The Coast Guard has recorded 30 inspections since 1984, most recently in September 2000, along with 65 deficiencies and 4 operational controls, 1 with no removal date recorded.

Records from 1984 to 2000. Most recent: inspection, 7 September 2000.

Built
1980
Last inspected
7 September 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

7907726 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227836
Flag
PHILIPPINES
—
Maury page id
psix-227836

Inspections, by type

…with no type recorded29
Years with a record 14 calendar years (1984–2000)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it10330 - Regulatory (Subpart C or D), Net Ton
17720 - Regulatory (Subpart C or D), Gross Ton
29026 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

7 September 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 281904
21 May 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 771166
20 May 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 210071
19 May 1998 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 416129
19 May 1998 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 416177
23 April 1998 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 415079
27 March 1995 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 376614
20 March 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 646359
15 March 1995 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 376488
21 February 1995 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 375365
6 October 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 646355
22 September 1994 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 370608
22 September 1994 Uninspected Other
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 870632
11 May 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 514129
14 September 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 361042
16 January 1992 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 348318
1 May 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 437086
12 October 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 339785
16 July 1990 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 510004
30 October 1989 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 333397
31 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 326564
16 February 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 514464
2 November 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 319376
17 August 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 317933
3 March 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 481513
5 November 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 312318
1 September 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 311033
16 January 1986 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 516807
16 June 1985 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 302542
13 November 1984 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 299053

Deficiency record · 65

Engineering
Issued 19 May 1998 Resolved
INSTALL BOTTOM FLANGES FOR DIESEL OIL TANK NEXT TO BOILER. SOLAS 74 CHPT I REG 11.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Fire Fighting
Issued 19 May 1998 Resolved
MAKE PERMANENT REPAIRS TO BILGE, BALLAST, AND FIRE PUMP PIPE. SOLAS 74 AMMENDED CHAP II 2/21.
Condition: Unknown
Due 20 May 1998
Resolved 26 May 1998
Construction/Loadline
Issued 19 May 1998 Resolved
REPAIR COMBING SUPPORT BRACKETS ON #1 CARGO HATCH (3 ON FORWARD SECTION, 3 ON AFT SECTION) AND #3 CARGO HATCH (2 ON AFT SECTION. ILLC 66 ANNEX I/1
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Engineering
Issued 19 May 1998 Resolved
INSTALL TEMPERATURE CONTROLL SWITCH ON AFT TURBO CHARGER AND PROVE PROPER OPERATION. SOLAS 74 REG. I/11
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Electrical
Issued 19 May 1998 Resolved
PROPERLY REPAIR AUX. GENERATOR SOCKET WATER COOLING LINE INSPECTION COVER PLATE. SOLAS 74 CHPT 1 REG 11.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Engineering
Issued 19 May 1998 Resolved
MAKE PERMANENT REPAIRS TO MAIN ENGINE SEA WATER COOLING LINE _x001C_ SOLAS 74 AMMENDED REG. II-1/26
Condition: Unknown
Due 20 May 1998
Resolved 26 May 1998
Engineering
Issued 19 May 1998 Resolved
MAKE PERMANENT REPAIRS TO DIESEL OIL SERVICE TANK SPRING VALVE. SOLAS 74 CHPT 1 REG 11
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Construction/Loadline
Issued 19 May 1998 Resolved
VESSELS HAS TO REPAIR 134 CRACKS ON THE INTERNAL FRAMES AT DECK LEVEL IN ALL CARGO HOLDS. TO MANY TO LIST ALL. ILLC 66 ANNEX I/1
Condition: Unknown
Due 23 May 1998
Resolved 26 May 1998
Electrical
Issued 19 May 1998 Resolved
REPLACE 30 LIGHT COVERS IN ENG ROOM SOLAS 60 CHAP II REG 34
Condition: Unknown
Due 20 May 1998
Resolved 21 May 1998
Lifesaving
Issued 19 May 1998 Resolved
VESSEL TO REMOVE EXCESSIVE OIL IN ENG ROOM BILGE AND ALL OVER THE MAIN ENGINGE, WALLS AND DECK. SOLAS 74 REG. II-2/33(a)
Condition: Unknown
Due 20 May 1998
Resolved 21 May 1998
Accommodation/Occupational Safety
Issued 19 May 1998 Resolved
MAKE REPAIRS TO AIR CONDITIONER SEA WATER INLET LINE TO CONTROL ROOM. CURRENT VSL USING FIRE HOSE TO REPLACE HARD PIPE. SOLAS 74 REG I/11
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Engineering
Issued 19 May 1998 Resolved
MAKE REPAIRS TO LEVEL INDICATOR ON HEAVY FUEL OIL SERVICE TANK(PACKING IS MISSING. SOLAS 74 CHPT 1 REG 11.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Fire Fighting
Issued 19 May 1998 Resolved
REPLACE TWO FIRE HOSES IN THE ENGINEROOM AND ONE FIRE HOSE ON THE FOC'SLE. SOLAS 60 REG. II/65(c)2
Condition: Unknown
Due 20 May 1998
Resolved 26 May 1998
Construction/Loadline
Issued 19 May 1998 Resolved
REPAIR ACCESS HATCHES FOR #1,#2, AND #3 CARGO HOLDS. ILLC 66 ANNEX I/18.
Condition: Unknown
Due 20 May 1998
Resolved 26 May 1998
Lifesaving
Issued 19 May 1998 Resolved
PROPERLY STOW FREON BOTTLES IN STEERING GEAR ROOM. 46 CFR 147.60(b)
Condition: Unknown
Due 23 May 1998
Resolved 26 May 1998
Documentation
Issued 23 April 1998 Resolved
Provide Solas Training Manuals on board vessel that can be read and understood by all members of the crew.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Fire Fighting
Issued 23 April 1998 Resolved
Repair or replace wasted fire main pipe in engine room. Pipe has a soft patch right under decking at the main fire pump. Pressure of fire main/pump was good when tested and soft patch was holding and in good condiction at time of inspection. This item was not on 5437 left with vsl.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Documentation
Issued 23 April 1998 Resolved
Insure all Muster Lists and Emergency Instructions are able to be read and understood by the members of the crew.
Condition: Unknown
Due 8 September 2000
Resolved 8 September 2000
Documentation
Issued 23 April 1998 Resolved
Provide a Sopep in a language that can be read by all of the crew.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Electrical
Issued 23 April 1998 Resolved
Provide safe wireing for all appliances in the kitchen and crew's (officersand non-officers) messing areas. Inspector found wires going through bulkheads and splices from appliances that were 220 volts in all of the above areas and extention cords littered these areas.
Condition: Unknown
Due 21 May 1998
Resolved 21 May 1998
Fire Fighting
Issued 27 March 1995 Resolved
EMERGENCY FIRE PUMP UNABLE TO PRODUCE ADEQUATE PRESSURE. MAKE PERMANENT REPAIR PRIOR TO RETURNING TO A U.S. PORT OF CALL._x001C_
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Lifesaving
Issued 27 March 1995 Resolved
BRIDGE WING LIFEBUOYS DO NOT MEET THE WEIGHT REQUIREMENT AS PER SOLAS CH III SEC II REG 31.7. REPLACE PRIOR TO DEPARTING SAN FRANCISCO BAY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 27 March 1995 Resolved
MARKINGS FOR LIFEBOAT MISSING. PUT ALL REQUIRED MARKINGS ON THE LIFEBOATS AS REUIRED BY SOLAS CH III SEC IV REG 41.9.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 27 March 1995 Resolved
FIREMAIN LINE HOLED IN THREE PLACES. MAKE PERMANENT REPAIRS TO FIREMAIN LINE PRIOR TO DEPARTING SAN FRANCISCO BAY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Fire Fighting
Issued 27 March 1995 Resolved
GALLEY RANGE HOOD FLAME SCREEN MISSING. INSTALL FLAME PRIOR TO DEPARTING SAN FRANCISCO BAY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Engineering
Issued 15 March 1995 Resolved
Make permanaent repairs to the lubrication cooler in way of the patches. (4were found). Make permanent repairs prior to departure from port, per SOLAS Chpt II-1 Reg 26_x001C_
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 15 March 1995 Resolved
Make permanent repairs to the generator engine's cooling pump discharge where wasted and leaking and to the elbow that is patched, prior to departure from port, per SOLAS Chpt II-1 Reg 26
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 15 March 1995 Resolved
Make permanent repairs to the wasted engineroom firepump piping in way of the three rubber patches and the temp welded patch at the "T" discharge into the overhead. Complete prior to departure from port, per SOLAS Chpt II-2 Reg 4.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 15 March 1995 Resolved
Make permanent repairs to the wasted cooling line to the generator engine lube oil cooler, prior to departure from port, per SOLAS Chpt II-1 Reg 26.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 15 March 1995 Resolved
Provide a closure device to the fire door from the steering gear room to_x001C_ the accommodation spaces. Remove the hold back device, prior to departure from port, per SOLAS Chpt II-2 Reg 45(3).
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Fire Fighting
Issued 15 March 1995 Resolved
Remove the hold back devices on the engineroom fire doors and the engineroom/steering gear room fire door, prior departure from port, per SOLAS Chpt II-2 Reg 47(2).
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Lifesaving
Issued 15 March 1995 Resolved
Clean the sprayed oil from about the #6 bunker line sight glass. Make permanent repairs to line, prior to departure from port, per SOLAS Chpt II-2 Reg 2.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Lifesaving
Issued 15 March 1995 Resolved
Clean the sprayed oil from the stbd, aft corner of the main engine. Establish reason for problem and fix, prior to departure from port, per SOLAS Chpt II-2 Reg 2.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Accommodation/Occupational Safety
Issued 15 March 1995 Resolved
Make permanent repairs to the wasted sewage overboard clean out trap (priorto sea valve), prior to next U. S. port, per SOLAS Chpt II-1 Reg 26. Trap was enclosed in a cement box and a condition of class given to the vessel by NKK.
Condition: Unknown
Due 27 April 1998
Resolved 27 April 1998
Navigation
Issued 22 September 1994 Resolved
NOAA chart 18524 was missing 4 corrections.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Engineering
Issued 22 September 1994 Resolved
Vessel's Oily Water Separater 15 ppm alarm was not functioning.
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Navigation
Issued 22 September 1994 Resolved
Vessel did not conduct emergency steering gear test prior to entry of port as was logged in the vessel's official log.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Accommodation/Occupational Safety
Issued 22 September 1994 Resolved
Remove hold-back on the fire door between the steering gear room and the engineroom prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-2 Reg 17 (2)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Lifesaving
Issued 22 September 1994 Resolved
Replace wasted bilge pump hose discharge in both lifeboats prior to departure from the port._x001C_ _x001C_ SOLAS Chpt III Reg 41 (8)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Lifesaving
Issued 22 September 1994 Resolved
Replace missing guard on A/C compressor belt drive prior to departure._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 22 September 1994 Resolved
Provide valid copy of the IOPP certificate Prior to departure from the port._x001C_ _x001C_ MARPOL Annex I (5)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Engineering
Issued 22 September 1994 Resolved
Remove cement patch and make permanent repairs to the M/E cooling line discharge in the lower level, stbd side engine room. Complete prior to 30OCT94 as per class report._x001C_ SOLAS Chpt II-2 26 (3)
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Lifesaving
Issued 22 September 1994 Resolved
Move the fwd 6 man life raft from inside the locker to out on deck prior todeparture._x001C_ _x001C_ SOLAS Chpt III Reg 19(2)
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Navigation
Issued 22 September 1994 Resolved
Mount instructions for emergency steering gear in the steering gear room prior to departure._x001C_ _x001C_ 33 CFR 164.35(k)
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Accommodation/Occupational Safety
Issued 22 September 1994 Resolved
Remove all paint from accommodation areas, rope stores and other storage areas prior to departure._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Accommodation/Occupational Safety
Issued 22 September 1994 Resolved
Repair hot water system on vessel prior to departure from the port._x001C_ _x001C_ _x001C_ ILO 147
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Documentation
Issued 22 September 1994 Resolved
Provide certification that all crew members on vessel have had satisfactorymedical exams within 2 years._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Demonstrate satisfactory Fire & Boat drill to the attending Coast Guard Inspector._x001C_ _x001C_ SOLAS Chpt III Reg 18 (3.1)
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Navigation
Issued 22 September 1994 Resolved
Demonstrate operation of the emergency steering gear prior to departure._x001C_ _x001C_ _x001C_ 33 CFR 164.25
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Engineering
Issued 22 September 1994 Resolved
Prove operation of oily water separator alarm and sampling system prior to departure from the port._x001C_ _x001C_ MARPOL Annex I (16)_x001C_
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Engineering
Issued 22 September 1994 Resolved
Make repairs to the leaks (2) on the generator cooling line pump discharge (lower level, port side). Finish prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-1 Reg 26 (3)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Construction/Loadline
Issued 22 September 1994 Resolved
Repair jury-rigged ballast valve in the lower level of the engineroom priorto departure from the port._x001C_ _x001C_ Load Line Conv Chpt II Reg 22 (2)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Accommodation/Occupational Safety
Issued 22 September 1994 Resolved
Provide documentation that the existing hot water supply system is as builtprior to return to a U.S. port._x001C_ _x001C_ ILO 147
Condition: Unknown
Due 22 September 1994
Resolved 22 September 1994
Lifesaving
Issued 22 September 1994 Resolved
Replace missing watch lifejackets in the engineroom control room prior to departure from the port._x001C_ _x001C_ SOLAS Chpt III Reg 7 (2.1)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Engineering
Issued 22 September 1994 Resolved
Repair excessive leakage from the stbd side overflow fuel line sight glass.Correct prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-2 reg 15 (2.4)
Condition: Unknown
Due 30 September 1994
Resolved 22 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Replace failed fire hose in the lower level of the engineroom prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-2 Reg 4 (7.1)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Replace missing fire hose from the bridge station prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-2 Reg 4 (7.1)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Replace 2 missing fire hoses from the two forward stations prior to departure from the port._x001C_ _x001C_ SOLAS Chpt II-2 Reg 4 (7.1)
Condition: Unknown
Due 30 September 1994
Resolved 26 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Remove existing gas masks and repalce with satisfactory fire fighting breathing devices in the emergency fire gear lockers._x001C_ _x001C_ SOLAS Chpt II-2 Reg 17 (3)
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Fire Fighting
Issued 22 September 1994 Resolved
Separate fire lockers to different locations about the ship prior to departure.
Condition: Unknown
Due 26 September 1994
Resolved 26 September 1994
Deck/Cargo
Issued 31 October 1988 Resolved
33CFR156.120(O) CONTAINMENT DRAIN NOT CLOSED BY MECHANICAL MEANS. AUTH: 33USC1321 PENALTY: 33USC1321
Condition: Unknown
Due 31 October 1988
Resolved 31 October 1988
Navigation
Issued 17 August 1987 Resolved
DEVIATION TABLE FOR MAGNETIC COMPASS NOT CURRENT AS REQUIRED BY 33CFR164.35(C).
Condition: Unknown
Due 17 August 1987
Resolved 17 August 1987
Navigation
Issued 1 September 1986 Resolved
VESSEL HAD NO TIDAL CURRENT TABLES ABOARD AS REQUIRED BY 33 CFR 164.33.
Condition: Unknown
Due 1 September 1986
Resolved 1 September 1986
Documentation
Issued 1 September 1986 Resolved
OIL TRANSFER PROCEDURES MISSING LIST OF PRODUCTS TRANSFERED AND TYPE OF COMMUNICATIONS.
Condition: Unknown
Due 1 September 1986
Resolved 1 September 1986
Navigation
Issued 16 June 1985 Resolved
VESSEL CHARTS AND PUBLICATIONS WERE NOT CURRENTLY CORRECTED AS REQUIRED.
Condition: Unknown
Due 16 June 1985
Resolved 16 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.