Records in 1997. Most recent: inspection, 25 July 1997.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Navigation
Issued 21 July 1997
Resolved
REPAIR LEAKING SEAL ON SERVO MOTOR LOCATED INSIDE STEARING GEAR HOUSING. TAKE NOTE OF ANY EXCESSIVE HYDRAULIC OIL ON TOP OF THE STEARING GEAR PINION. IF SEAL HAS NOT BEEN REPLACED, THIS IS MOST LIKELY WHERE THE EXCESSIVE OIL WILL BE.
Condition: Unknown
Due 30 August 1997
Resolved 14 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 21 July 1997
Resolved
STOW ALL LOOSE GEAR ADRIFT IN STEERING ROOM FLAT.
Condition: Unknown
Due 30 August 1997
Resolved 14 January 2002
Resolution: Administratively closed due to age of deficiencies.
Construction/Loadline
Issued 21 July 1997
Resolved
REPAIR RUSTED AND BROKEN BOTTOM LADDER STEP LOCATED ON PORT SIDE 3RD DECK._x001C_ICLL 66 R25
Condition: Unknown
Due 30 August 1997
Resolved 14 January 2002
Resolution: Administratively closed due to age of deficiencies.
Lifesaving
Issued 21 July 1997
Resolved
REPLACE ALL FLAME SCREENS FOR ALL FUEL TANK VENTS.
Condition: Unknown
Due 30 August 1997
Resolved 14 January 2002
Resolution: Administratively closed due to age of deficiencies.
Documentation
Issued 18 April 1997
Resolved
Provide waste management plan as recommended by MARPOL V/4.2.
Condition: Unknown
Due 31 July 1997
Resolved 31 July 1997
Navigation
Issued 18 April 1997
Resolved
Provide up to date navigation charts as required by SOLAS 74, Chap V/20.
Condition: Unknown
Due 18 April 1997
Resolved 20 April 1997
Accommodation/Occupational Safety
Issued 18 April 1997
Resolved
Clean oil from engineroom deck plating currently causing personnell hazard and not in accordance with the general requirements of ILO-147.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Documentation
Issued 18 April 1997
Resolved
Provide proper Discharge of Oil Prohibited placard in accordance with 33 CFR 155.450.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Documentation
Issued 18 April 1997
Resolved
Vessel sludge tanks 100 percent full, no way to deal with additional bilgeslops which exist in engineroom bilges as required by 33 CFR 155.370. Vessel to provide reciept that slops have been discharged to oil reception facility.
Condition: Unknown
Due 18 April 1997
Resolved 20 April 1997
Lifesaving
Issued 18 April 1997
Resolved
Liferafts not stowed in float free condition as required by SOLAS 74 Chap. III/29.
Condition: Unknown
Due 18 April 1997
Resolved 20 April 1997
Construction/Loadline
Issued 18 April 1997
Resolved
Repair ventilation openings and closures for ballast tank, fuel tank, and air vents as required by Loadline convention 1966, Reg.20.
Condition: Unknown
Due 18 May 1997
Resolved 14 January 2002
Resolution: Administratively closed due to age of deficiencies.
Electrical
Issued 18 April 1997
Resolved
Repair light in paint locker as required by ILO-147.
Condition: Unknown
Due 18 April 1997
Resolved 20 April 1997