MAURY USCG vessel records Sign in
← All vessels

WINDSOR

WINDSOR is a 1980 tank ship. The Coast Guard has recorded 9 inspections since 1984, most recently in November 2002, along with 4 deficiencies — 1 with no resolution recorded — and 1 operational control.

Records from 1984 to 2002. Most recent: operational control imposed, 29 November 2002.

Built
1980
Last inspected
29 November 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7912836 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227895
Flag
UNITED KINGDOM
—
Maury page id
psix-227895

Inspections, by type

…with no type recorded8
…past their stated due date1
Years with a record 7 calendar years (1984–2002)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it49809 - Convention (Subpart B), Gross Ton
22574 - Convention (Subpart B), Net Ton
88821 - Dead Weight, Ton
103191 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

29 November 2002 Ballast Water Examination · Certificate of Compliance
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1712394
24 May 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 278213
30 June 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 430262
16 April 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 415036
31 August 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 311145
11 May 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 525573
11 February 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 467461
17 August 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 533368
30 July 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 508349

Deficiency record · 4

Deck/Cargo › Inert Gas System
Issued 29 November 2002 Resolved
The inert gas system's installed oxygen analyzer does not operate. Vessel allowed a one time discharge of cargo with an alternative arrangement using portable instruments and amended transfer procedures. LEGACY COMPONENT DESC: Oxygen Analyzer
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 November 2002
Resolved 3 December 2002
Resolution: Received class report from DNV attesting to the install of a new oxygen analyzer and satisfactory test.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 29 November 2002 No resolution recorded
Three out of four fireman's suits are in poor condition. Replace or repair to the satisfaction of class.
Condition: Unknown
Action required: 705 - Other - as specified
Due 6 December 2002 — due date passed with no resolution recorded
Engineering › Fuel Oil Storage/Transfer System
Issued 29 November 2002 Resolved
Vessel's bunker line is not tested in accordance with 33 CFR 156.170. Vessel is prohibited from bunkering in waters of the United States until test is completed and satisfactory. Vessel is allowed a one-time bunkering transfer. LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Due 29 November 2002
Resolved 30 December 2002
Resolution: Reviewed proof of testing records for bunkerline.
Deck/Cargo
Issued 16 April 1998 Resolved
VESSEL NOT EQUIPPED WITH OVERFILL ALARMS.
Condition: Unknown
Due 1 July 1999
Resolved 1 July 1999

Ownership record