MAURY USCG vessel records Sign in
← All vessels

PELANDER

PELANDER is a 1979 freight ship. The Coast Guard has recorded 30 inspections since 1986, most recently in November 2007, along with 14 deficiencies — 1 with no resolution recorded — and 2 operational controls.

Records from 1986 to 2007. Most recent: operational control imposed, 27 November 2007.

Built
1979
Last inspected
27 November 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7913115 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227906
Flag
LIBERIA
—
Maury page id
psix-227906

Inspections, by type

…with no type recorded16
…past their stated due date1
Years with a record 16 calendar years (1986–2007)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Ro-Ro Cargo Ship class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it24891 - Convention (Subpart B), Gross Ton
24891 - Simplified, Gross Ton
15335 - Convention (Subpart B), Net Ton
15335 - Simplified, Net Ton
11080 - Dead Weight, Ton
18921 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 30

27 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3105481
24 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3103402
21 November 2007 Administrative Inspection
Administrative · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3102366
3 March 2006 Deficiency Check · ISPS I Exam · PI Safety Exam · Ballast Water Examination
Physical examination · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 2594376
27 July 2005 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2442280
14 June 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2390157
15 March 2005 Type not recorded
No type recorded · Sector Astoria · USCG Northwest District (CGD-NW) · Activity 2311197
23 December 2004 Random ISPS/MTSA/PSC · Ballast Water Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2264166
16 September 2004 Re-Inspection · ISPS II Exam
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2196875
1 April 2004 Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2035648
4 March 2004 Ballast Water Examination · MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2015727
21 February 2003 Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1747802
18 November 2002 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1706898
9 October 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1687655
8 October 2002 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1687851
12 April 2002 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1604283
10 April 2002 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1604190
31 January 2002 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1483770
2 July 2001 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 291499
22 October 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 283416
22 December 1998 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 423916
15 June 1997 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 404588
15 October 1993 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 361371
29 April 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 489743
8 October 1992 Type not recorded
No type recorded · MSD CONCORD · USCG Southwest District (CGD-SW) · Activity 504383
27 November 1991 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 347461
24 July 1988 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 324664
11 August 1987 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 517340
13 February 1987 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 314306
21 January 1986 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306554

Deficiency record · 14

Navigation › Piloting/Steering › Gyro Compass
Issued 27 November 2007 No resolution recorded
Vessel requested to sail with an inoperable gyrocompass, after review of tech report stating that he couldn’t fix do to not able to get parts. We issued a LOD for the vessel to sail with restrictions. Vessel stated they are going to Japan were the gyrocompass will be replace. LOD stated that gyrocompass must be repaired prior to next US port.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 28 November 2007 — due date passed with no resolution recorded
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 3 March 2006 Resolved
Toilet in hospital space inoperable. Correct to satisfaction of class, prior to next U.S port.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2006
Construction/Loadline › Structures › Superstructure
Issued 3 March 2006 Resolved
2 inch diameter hole in hospital space bulkhead. Correct to the satisfaction of class, prior to next U.S. port. Violation of SOLAS 60 Regulation 17.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2006
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 3 March 2006 Resolved
Verify measurements of F/O day tanks and settling tanks to the satisfaction of class, prior to next U.S. port.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 13 March 2006
Fire Fighting › Emergency Fire Pumps › Power Source
Issued 3 March 2006 Resolved
Demonstrate proper operation of emergency fire pump. Correct to the satisfaction of U.S. Coast Guard inspector, prior to departure. Violation of SOLAS 60 Regulation 65.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2006
Resolution: Repairs made to emergency fire pump and proper operation demonstrated to U.S. Coast Guard inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 3 March 2006 Resolved
Demonstrate proper operation of fire and balast pump. Correct to the satisfaction of the U.S. Coast Guard inspector, prior to departure. Violation of SOLAS 60 Reg 65.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 March 2006
Resolution: Repairs made to the fire and ballast pump and proper operation demonstrated to U.S. Coast Guard inspector.
Engineering › Freshwater System (intermediary cooling)
Issued 4 March 2004 Resolved
Make repairs to the satisfactiion of the class society to the piping with leaks or temporary patches. The pipes idenitfied are: Intermediate shaft cooling line, piping entering the MSD and the freshwater line to the car deck adjacent to the incinerator. SOLAS 60 I / II LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2004
Resolution: Received class report confirming completion of satisfactory repairs.
Construction/Loadline › Penetrations
Issued 4 March 2004 Resolved
Make repairs to the satisfaction of class or provide approval by class of the holes in the deck in the engine room adjacent to the boiler feed pumps. Holes appear to have been drilled in the deck to drain water down to the bilge. SOLAS 60 I / II
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2004
Resolution: Received class report confirming completion of satisfactory repairs.
Construction/Loadline › Structures
Issued 4 March 2004 Resolved
Remove or provide approval by class of the toilet with plywood walls installed adjacent to the MSD. If approved by class ensure toilet piping does not leak. SOLAS 60 I / II
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2004
Resolution: Received class report confirming completion of satisfactory repairs. The plywood walls were removed and replaced by steel plates.
Construction/Loadline › Structures
Issued 4 March 2004 Resolved
Provide approval by class of the wiring of the electrical junction box in the steering gear flat. SOLAS 60 I/II. This junction box appears to have been added for the welding equipment.
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2004
Resolution: Received class report confirming completion of satisfactory repairs to the wiring.
Construction/Loadline › Structures
Issued 31 January 2002 Resolved
Weather deck door, port side, aft, to COMP #2 securing device (dog) on bottom port corner inoperable. Ensure corrected in accordance with ICLL 66/Anx 1/Reg 12 prior to departure. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 31 January 2002
Resolved 31 January 2002
Resolution: Freed dog and properly secured door.
Construction/Loadline › Structures
Issued 31 January 2002 Resolved
Main deck, port side aft weather deck access door to pollution contingency locker badly wasted in way of gasket channel and knife edge. Make access weathertight in accordance with ICLL 66/Anx 1/Reg12. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 28 February 2002
Resolved 12 April 2002
Resolution: new gasket installed in door
Construction/Loadline › Structures
Issued 31 January 2002 Resolved
Weathertight door, port side, in way of food stores does not close properly. Correct same in accordance with ICLL 66/Anx 1/Reg 12. LEGACY COMPONENT DESC: Door
Due 28 February 2002
Resolved 12 April 2002
Resolution: new gasket installed in door
Documentation
Issued 22 December 1998 Resolved
VESSEL RESPONSE PLAN POLLUTION AND SHIPBOARD OIL POLLUTION EMERGENCY PLAN ARE THE SAME DOCUMENT, PER THE OPERATOR, BUT DO NOT APPEAR TO HAVE BEEN APPROVED BY THE FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 8 February 1999
Resolved 8 February 1999

Ownership record