MAURY USCG vessel records Sign in
← All vessels

MIDNIGHT DREAM

MIDNIGHT DREAM is a 1980 freight ship. The Coast Guard has recorded 98 inspections since 1984, most recently in March 2024, along with 71 deficiencies and 9 operational controls.

Records from 1984 to 2024. Most recent: inspection, 1 March 2024.

Built
1980
Last inspected
1 March 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7913206 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
227912
Flag
VANUATU
—
Maury page id
psix-227912

Inspections, by type

…with no type recorded52
Years with a record 37 calendar years (1984–2024)
The 98 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it548 - Convention (Subpart B), Net Ton
1827 - Convention (Subpart B), Gross Ton
2530 - Dead Weight, Ton
4200 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 98

1 March 2024 PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7872555
25 March 2022 PSC B
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7418386
11 May 2021 PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7191543
12 November 2020 PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 7089394
13 May 2020 PSC A
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6951332
28 January 2020 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6898458
19 December 2019 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6874042
9 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6870290
14 November 2019 ISPS III Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6849957
29 August 2019 Deficiency Check
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 6798421
6 August 2019 Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6774592
10 July 2019 Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6744803
12 June 2019 NPV Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6705718
28 February 2019 Administrative Inspection · In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6634511
11 January 2019 ISPS II Exam · PI Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6608965
12 May 2018 ISPS III Exam · Deficiency Check · ILO-147 Exam · ISM Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6411204
3 December 2017 ISPS III Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6315628
16 June 2017 ISPS III Exam · PII Safety Exam · Deficiency Check
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6176559
3 February 2017 Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6082157
18 January 2017 ISPS II Exam · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6072966
15 December 2016 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 6056436
17 June 2016 Ballast Water Examination · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 5910541
18 December 2015 PI Safety Exam · Ballast Water Examination · ISPS III Exam
Physical examination · Resident Inspection Office Ponce · USCG Southeast District (CGD-SE) · Activity 5781314
19 June 2012 ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4349248
26 May 2012 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4328348
13 December 2011 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4207460
13 December 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4207482
12 December 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4207420
7 September 2011 PII Safety Exam · ISPS III Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4137603
7 September 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4140090
17 August 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 4140151
2 October 2010 Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3861536
24 February 2010 ISPS III Exam · PII Safety Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3685200
26 January 2009 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3400095
14 May 2008 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3205256
15 January 2008 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 3130791
11 June 2007 PII Safety Exam · ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2958009
29 July 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2729528
2 May 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2639326
29 March 2006 ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2611789
17 March 2006 NPV Safety Exam · MARPOL Annex V Examination · Ballast Water Examination · ISPS II Exam · MARPOL Annex I Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2604439
11 March 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2600401
10 March 2006 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2599994
4 March 2006 MARPOL Annex V Examination · MARPOL Annex I Examination · NPV Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2595492
5 October 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2508204
5 October 2005 MARPOL Annex I Examination · MARPOL Annex V Examination · Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2508595
4 October 2005 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2507834
26 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343251
26 April 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2343877
25 April 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2341990
12 April 2005 Ballast Water Examination · MARPOL Annex I Examination · NPV Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2331870
5 April 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2326740
19 March 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2317518
25 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2302721
11 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297653
4 February 2005 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 2297596
1 February 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2284767
23 November 2004 PII Safety Exam · Ballast Water Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2246587
2 July 2004 ISPS II Exam
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2117706
20 February 2004 Deficiency Check
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2007555
28 January 2004 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2001901
14 October 2003 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1928161
16 July 2003 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1847693
5 May 2003 Type not recorded
No type recorded · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1788971
10 March 2003 Annual Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1762594
28 May 2002 Passenger/Freight Vessel Examination
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1621748
31 July 2001 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 292537
16 March 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 288439
26 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274216
28 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431204
2 June 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 130017
15 January 1999 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 424125
23 June 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 417281
9 January 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 411495
25 December 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 411218
25 December 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 411779
22 January 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 399712
21 December 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 398761
4 December 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 398044
18 November 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 398104
27 October 1996 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 396684
2 December 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 385402
31 August 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 370153
31 August 1994 MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1170990
8 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367549
27 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367241
18 November 1993 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 362504
24 June 1993 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 359309
27 April 1992 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 458246
10 December 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 347956
1 May 1990 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 340243
22 August 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 332211
12 November 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 320152
2 June 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 309238
22 November 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 305551
25 October 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 505300
17 April 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 301451
12 September 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 297905

Deficiency record · 71

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil filtering equipment
Issued 1 March 2024 Resolved
MARPOL ANNEX I/14.6 Oil filtering equipment shall be such as will ensure that any oily mixture discharged into the sea after passing through the system has an oil content not exceeding 15 ppm. The oily water separator sample line leading into the oil content meter was obstructed preventing accurate sampling of oily water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2024
Resolution: Class report received attesting to satisfactory repair.
10 - Safety of Navigation › N/A - No Subsystem › Gyro compass
Issued 14 November 2019 Resolved
Each vessel must have a Gyro compass. The vessel is operating without a functioning gyro compass - 33CFR164.35(d)- 40C - Deficiency changed due to a COTP issued for a long term LOD until 20JAN20 / Please see below requiremnet/resolution
Action required: 705 - Other - as specified
Due 20 January 2020
Resolved 28 January 2020
Resolution: MSD STT received and accepted technician report and pictures attesting to the proper repair of the inoperable gyro compass. 01 Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Construction (including exempt.)
Issued 14 November 2019 Resolved
Certificates issued shall be readily available on board for examination at all times. Safety construction certificate was not on board for examination. 74SOLAS14 CH 1 REG 16 16BC
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 November 2019
Resolved 5 December 2019
Resolution: Vessel provided valid copy of Solas Safety Construction Certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 14 November 2019 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The Portside engine insulation that creates a heat shield is torn and deteriorated. 74SOLAS14 CH 1 REG 11 (a) 50BC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 19 December 2019
Resolution: MSD STT PSCO's attended vessel and verified proper installation of port side engine casing. All found in proper working order.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 14 November 2019 Resolved
A Class Divisions formed by bulkheads shall be constructed of steel or other equivalent material. Bulkhead between chartroom and wheelhouse is missing Class A material. Common toilet door located on hold deck is made of wood. 60SOLAS PARTD CHII REG35(c)(i) 50BC
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2019
Resolved 19 December 2019
Resolution: MSD STT PSCO's attended vessel and verified proper installation of class A division items. All found in proper working order.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 10 July 2019 Resolved
Class 2 - hand operated sliding doors when operating hand gear the time necessary for the complete closure of the door with the vessel upright, shall not exceed 90 seconds. Watertight doors located in the below cargo deck do not close in the required time - 60 SOLAS II/13(h) - 50bc
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2019
Resolved 29 August 2019
Resolution: Repairs conducted to satifaction of Administration. Document uploaded.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 12 June 2019 Resolved
The Oil Record Book shall be in the form specified in Appendix III to this Annex. Multiple list of items to be recorded in the Oil Record Book Part 1 are inaccurately written according to this prescribed Annex. MARPOL 2017 1/17.1 - 50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 July 2019
Resolved 10 July 2019
Resolution: MSD STT conducted deficiency check onboard. Oil record book was reviewed by PSCO and all items were recorded satisfactory since 12JUN19.
01 - Certificates & Documentation › 012 - Crew Certificates › Endorsement by flagstate
Issued 28 February 2019 Resolved
The capacity in which the holder of certificate is authorized to serve shall be identified in the form of endorsement in term identical to those used in the applicable safe manning requirements of the administration. 02 able seafarer and 01 able seafarer engineer do not possess flag endorsements as required by minimum safe manning certificate - 95 STCW(11 cons) Reg I/2.9 - 15bc
Action required: 15 - Rectify deficiencies by next port
Resolved 1 March 2019
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Safety Management System › Conformity Maintenance Procedures
Issued 12 May 2018 Resolved
Objective evidence discovered during an expanded ISM exam revealed the following non-conformities: the crew failed to fully implement the requirements of the ISM Code through their SMS procedures. These identified deficiencies are evidence that the ship and/or company are not meeting the SMS requirements. Recommend an external audit. See Form B.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Construction/Loadline › Structures › Deck Plating
Issued 12 May 2018 Resolved
The Administration shall satisfy itself that the general structural strength of the hull is sufficient for the draught corresponding to the freeboard assigned. The material strength of the main deck, which carries thousands of pounds of cargo including dangerous goods in greater than limited or excepted quantities, is severely wasted and compromised; there are currently eight confirmed wastage holes allowing water to enter directly into the main machinery space and under-deck cargo space. The vessel has no proof of recent deck gauging, including during the 2016 dry-dock, and the SOLAS Cargo Ship Safety Construction Certificate lists the previous dry-dock date as "UNKNOWN."
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a wastage hole, approximately two inches in diameter, in the watertight bulkhead between the engine room and the under-deck cargo space.
Action required: 30 - Ship detained
Resolved 25 May 2018
Resolution: Area has been cropped and renewed satisfactorily
Personnel › Certificates/Documents/Licenses › License, Master
Issued 12 May 2018 Resolved
Deficiencies which may be deemed to pose a danger to persons, property or the environment include the following: failure of seafarers to have an appropriate certificate. The master's license, endorsed by the Administration with the same limitation, was limited to vessels up to 1,600 gross tons. The vessel's gross tonnage is 1,827. The master served on board from 30 March 2018 to 12 May 2018.
Action required: 30 - Ship detained
Resolved 25 May 2018
Resolution: Proper license and endorsement onboard
Fire Fighting › Ventilation Systems › Ducts
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The ventilation ducts in the main machinery space are severely wasted with multiple penetrations making closure at the vent inlet irrelevant and compromising the fire division of the engine room with the rest of the vessel in addition to adversely affecting distribution of CO2 in the event of an engine room fire.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There is a wastage hole in the fire class division between the below deck crew accommodation space corridor and the under-deck cargo space in the top right corner of the fire door frame.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. According to the crew, the fire door referred to in the above deficiency had a lock removed about two months ago compromising the class division. An adhesive foam pad was used to cover the hole in lieu of a permanent repair.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 12 May 2018 Resolved
lans and booklets shall be kept up-to-date, any alterations being recorded thereon as soon as practicable. The fire control plan indicates there are twenty-three fire detectors "Connected to Fire Alarm Panel." However, all modular household smoke detectors in the accommodation spaces, service spaces, and control station (counted as part of the twenty-three) are not connected to a fire alarm panel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2018
Resolution: Fire plan was updated to the satisfaction of the attending surveyor
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The Fire [name withheld] indicates the door to the bridge should be self-closing, and the door is not self-closing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2018
Resolution: self closing device was renewed and verified
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. The MEPC.107(49) oily water separator has a test sample discharge line with a threaded pipe and a hose at its termination after the oil content meter three-way valve. This test sample discharge line is not on the manufacturer's manual and, there is no Flag Letter approving this addition to the OWS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2018
Resolution: OWS overboard piping repair SAT
Fire Fighting › Fire Pumps › Gland Sealing
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The emergency fire pump is leaking at a rate of approximately five gallons per minute, so excessively that a bucket was placed under it to mitigate water level.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. There are soft patches on heat exchanger pumps in the emergency fire pump space which are an unauthorized temporary repair.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2018
Resolution: The leaky piping has been renewed and satisfactorily tested
Lifesaving › Launching Appliances › Release Mechanism
Issued 12 May 2018 Resolved
Notwithstanding paragraph 4.2, for all ships, not later than the first scheduled dry-docking after 1 July 2014, but not later than 1 July 2019, lifeboat on-load release mechanisms not complying with paragraphs 4.4.7.6.5 to 4.4.7.6.6 of the Code shall be replaced with equipment that complies with the Code. The last dry-dock was 22 November 2016, and the lifeboat hooks are not the on-load release type complying with paragraphs 4.4.7.6.5 to 4.4.7.6.6.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Lifesaving › Launching Appliances › Davit
Issued 12 May 2018 Resolved
For ships constructed before 1 July 1998, the Administration shall: ensure that when life-saving appliances or arrangements on such ships are replaced such life-saving appliances or arrangements, in so far as is reasonable and practicable, comply with the requirements of this chapter. Launching arrangements shall comply with the requirements of regulation 16. Unless expressly provided otherwise, launching and embarkation appliances complying with the requirements of section 6.1 of the Code shall be provided. The davit is not certified for the rescue boat which was recently installed to replace the previous one. The Flag Administration issued a "Letter of Comfort" indicating the davit should be replaced by 30 April 2018; however, the davit has not been replaced.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 September 2018
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Lifesaving › Lifebuoys › Size
Issued 12 May 2018 Resolved
At least eight lifebuoys of a type which satisfies the requirements of Regulation 21 of this Chapter shall be provided. Every lifebuoy shall: if it is intended to operate the quick-release arrangement provided for the self-activated smoke signals and self-igniting lights, have a mass of not less than 4 kg. The quick-release ring lifebuoys were not the 4 kg type.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2018
Resolution: The crew found the appropriate weighted buoys elsewhere onboard and installed them properly.
Deck/Cargo › Mooring/Anchoring › Anchor Chain (general)
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Nearly all of the observable anchor chain links were cracked. Numerous chain link studs were cracked and some were missing altogether. The anchor chain of both anchors is in substantial need of replacement.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Engineering › Fuel Oil Service System › Piping
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. The port side generator had significant oil leaks creating a fire hazard. The jacket water pump serving the same generator had soft patches, was highly corroded/wasted, and was leaking at approximately four drops per second.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 May 2018
Deck/Cargo › Cargo Stowage › General
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Several cargo securing points, D-rings, on deck are extremely wasted visually appearing to be wasted/worn beyond 75%) creating a stability hazard if they fail and cargo breaks loose.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 May 2018 Resolved
Satisfactory means (in the form of guard rails, lifelines, gangways or underdeck passages, etc.) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space and all other parts used in the necessary work of the ship. There are platforms above the bulwarks running nearly the length of the ship on either side of and ten feet above the cargo deck. The crew's normal practice is to use these platforms when loaded with cargo to maximize usable deck space. In the event of a deck fire, these platforms would be used for fire-fighting purposes. Externally, efficient guard rails are provided in accordance with the 66 Load Lines Convention. Internally, stanchions are fitted with nylon lines for all three rungs (top "rail" and bottom two courses) running the entire length of the platforms, which is not in accordance with the unified interpretations of Load Lines. In addition, there are multiple guard rails in the engine room which are fractured.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 May 2018 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Multiple light fixtures throughout the engine room are missing covers, leaving the fluorescent bulbs exposed and creating an ignition hazard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2018
Resolution: Light fixtures were fitted with proper covers.
Personnel › Training › Ship's Business
Issued 12 May 2018 Resolved
A hazmat employee must receive the training required by this subpart at least once every three years. The master and deck officer could not provide proof of HAZMAT training, and the vessel regularly carries dangerous cargo.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 May 2018
Resolution: Proof of Hazmat training was provided.
Construction/Loadline › Structures › End Bulkhead
Issued 12 May 2018 Resolved
Bulkheads at exposed ends of enclosed superstructures shall be of efficient construction and shall be to the satisfaction of the Administration. A hole was drilled through the control station (navigation bridge) bulkhead to run wires for navigation equipment and was then sealed with silicone.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2018
Resolution: Penetration was properly sealed.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 May 2018 Resolved
The normal equipment of every lifeboat shall consist of: a food ration as described in paragraph 4.1.5.1.18 totalling not less than 10,000 kJ for each person the lifeboat is permitted to accommodate. The starboard side lifeboat was missing one food ration.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2018
Resolution: Replacement food ration was provided.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 12 May 2018 Resolved
Every ship to which Chapter 1 applies shall carry an appropriate portable atmosphere-testing instrument. As a minimum, these shall be capable of measuring concentrations of oxygen, flammable gases of vapors, hydrogen sulfide and carbon monoxide prior to entry into enclosed spaces. Suitable means shall be provided for the calibration of all such instruments. The vessel does not have a means to calibrate the portable atmosphere testing instrument onboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 May 2018
Documentation › Certificates/Documents › International Load Line Certificate
Issued 12 May 2018 Resolved
The International Load Line Certificate (1966) shall not be delivered to the ship until the officer or surveyor acting under the provisions of article 13 of the present Convention has certified that the marks are correctly and permanently indicated on the ship’s sides. The Load Line markings are in Spanish whereas the certificate’s Load Line markings are in English.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Navigation › Piloting/Steering › Gyro Compass
Issued 12 May 2018 Resolved
Each vessel must have the following: a gyrocompass. The vessel has a magnetic and satellite compass but does not have a gyrocompass required by 33 CFR for vessels over 1,600 gross tons.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 January 2019
Resolution: Recieved and verified Flag attestation to proper operation.
Operations/Management › Drills/Instruction › Fire
Issued 16 June 2017 Resolved
74 SOLAS (2004) III/REG 19.2.1 PSCO's observed that the fire team members were unfamiliar with the ships procedures, techniques and tactics for combating fire. In particular the fire team members were unable to properly don the ships fire outfits and SCBA's. They were also unable to properly communicate due to a language barrier between varying crew members.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 July 2017
Resolved 17 June 2017
Resolution: Crew completed fire drill to the satisfactino of the attending Coast Guard Marine Inspector.
Documentation › Logs/Records › Logbook (official)
Issued 16 June 2017 Resolved
74 SOLAS (2004) III REG 19.5 FIRE DRILLS NOT LOGGED AS PRESCRIBED BY ADMINSTRATION.
Action required: 705 - Other - as specified
Due 17 July 2017
Resolved 10 July 2017
Resolution: Received copies of the official and deck log books, onboard checklists, and letter from Flag State.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 15 December 2016 Resolved
0715 - all fire detection systems shall be capable of automatically indicating the precentce or indication of fire. PSCO found three smoke detectors with covers on effectively taking them out of service in engine room. 60SOLAS II \ 61(a) 10c
Condition: Damaged By Earlier Event
Due 15 December 2016
Resolved 15 December 2016
Documentation › Logs/Records › Oil Record Book
Issued 15 December 2016 Resolved
2110 - everyship of 400GT shall be provided with an oil record book part I. Oil record book shall be completed on each occasion when .3 collection of oily residues. ORB requires weekly soundings of all tanks listed on ships IOPP supplement under 3.1. Ship's ORB missing weekly soundings for last two months. - 73MARPOL2011 Annex I/ 17.2.3 - 10c
Condition: Improper Installation
Due 15 December 2016
Resolved 15 December 2016
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 17 June 2016 Resolved
At least one detector shall be installed in each space where detection facilities are required. Fire detector in stearing gear room was inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2016
Resolution: Received a letter from flag state allowing the vessel to sail until they could fix the fire detectors in the steering gear room.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 June 2016 Resolved
Spare detectors shall be provided for each section of detection to the satisfactory of the administration. Master stated that vessel did not have spare dectors on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 June 2016
Resolution: Received a letter from flag state allowing the vessel to sail until they could fix the fire detectors and purchase some spares for the steering gear room.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 13 December 2011 Resolved
Cargo Ship Safety Equipment Certificate invalid because the stbd lifeboat and stbd davits were under repair. Flag issued a 30 day extension for the repairs to be made to the lifebat and davits no later than 11Jan2012
Action required: 705 - Other - as specified
Due 26 February 2012
Resolved 7 March 2012
Resolution: Received class attestation to repair of starboard lifeboat and davits.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 14 May 2008 Resolved
Life jacket lights missing batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 May 2008
Lifesaving › Lifeboat › Markings
Issued 14 May 2008 Resolved
Retroreflective material on hull wasted and worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 May 2008
Resolved 14 May 2008
Personnel › Certificates/Documents/Licenses › License, Master
Issued 5 October 2005 Resolved
Crewmembers do not have valid flag administration endorsements on board: Master and Chief Engineer certificate numbers on endorsements do not match certificate numbers on national licenses. Rectify to the satisfaction of the flag administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 October 2005
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 5 October 2005 Resolved
Air conditioner cooling pump not properly maintained: Gauge line for discharge pressure at pupm wasted/fractured; gauge inoperable, water leaks into space. Rectify to the satisfaction of the flag administration.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 October 2005
Lifesaving › Lifeboat Equipment › Food Ration
Issued 12 April 2005 Resolved
STBD lifeboat fod rations severely wasted. Replace wasted food rations.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2005
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle
Issued 12 April 2005 Resolved
SCBA bottle is insufficiently charged. Properly recharge. Provide receipt to Sector Miami.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 April 2005
Documentation › Logs/Records › Oil Record Book
Issued 12 April 2005 Resolved
Oil record book does not accurately reflect ballast water operations in conjunction with Ballast Water Management Plan report form. To the satisfaction of the administration.
Due 20 April 2005
Resolved 26 April 2005
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 23 November 2004 Resolved
Missing flag state endorsements for the master, chief mate, 1st engineer, 2nd engineer, and 2nd mate. (fax proof, via office)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2004
Resolution: Received fax.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 23 November 2004 Resolved
Missing 17 food rations for lifeboat inventory. Provide proof of purchase, via fax receipt to Coast Guard office.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2004
Resolution: Received receipt.
Fire Fighting › Fire Main › Condition
Issued 23 November 2004 Resolved
Sprinkler system pipe for paint locker is holed and wasted. (Properly repair to satisfaction of administration. Provide report via Coast Guard office.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 November 2004
Resolution: Received report.
Documentation › Safety Management System
Issued 28 January 2004 Resolved
Conduct a safety management audit and provide a report of findings to the U. S. Coast Guard iaw Solas 74 chapter IX Reg 4.3. LEGACY COMPONENT DESC: Potential Emergency Situations ID Procedures
Action required: 705 - Other - as specified
Due 11 February 2004
Resolved 20 February 2004
Personnel › Training
Issued 28 January 2004 Resolved
Conduct a fire and man overboard drill in the presence of Coast Guard marine inspectors iaw Solas 74, chapter III reg 19.3. LEGACY COMPONENT DESC: Fire Fighting Basic
Action required: 705 - Other - as specified
Due 11 February 2004
Resolved 20 February 2004
Fire Fighting › Firemans Outfit
Issued 28 January 2004 Resolved
Refill one SCBA cylinder iaw Solas 74 chapter II reg 17. LEGACY COMPONENT DESC: Self-Contained Breathing Apparatus
Action required: 17 - Rectify deficiencies prior to departure
Due 11 February 2004
Resolved 20 February 2004
Pollution Prevention/Response › Prevention Equipment
Issued 10 March 2003 Resolved
OILY WATER SEPERATOR NOT OPERATIONAL. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2003
Resolved 14 March 2003
Lifesaving › Lifebuoys
Issued 10 March 2003 Resolved
ALL RING BOUYS NOT ARRANGED FOR QUICK RELEASE. LEGACY COMPONENT DESC: Stowage
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2003
Resolved 14 March 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 March 2003 Resolved
PROTECTIVE GUARDS NOT PROVIDED FOR ALL SIGHT GLASSES THROUGHOUT ENGINE ROOM AND PORT MAIN ENGINE DAY TANK SIGHT GLASS TO BE CONDEMENED. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Engineering › Fuel Oil Service System
Issued 10 March 2003 Resolved
FLMAE BOWLS AND MATALLIC DRAINS NOT PROVIDED FOR ON ALL FUEL OIL FILTERS THROUGHOUT ENGINE ROOM. LEGACY COMPONENT DESC: Filter
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Construction/Loadline › Structures
Issued 10 March 2003 Resolved
CARGO HOLD HYDRALIC SLIDEING WTD NOT WORKING PROPERLY. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2003
Resolved 14 March 2003
Documentation › Safety/Response Plans/Programs
Issued 10 March 2003 Resolved
FIRE SAFETY PALN DOES NOT REFLECT PROPER LOCATION OF INTERNATIONAL SHORE CONNECTION. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Lifesaving › Lifeboat
Issued 10 March 2003 Resolved
PORT LIFEBOAT RELEASE SHACKLE EXCESSIVLEY PITTED AND TO BE REPLACED. LEGACY COMPONENT DESC: SHACKLE
Action required: 705 - Other - as specified
Due 24 March 2003
Resolved 25 March 2003
Lifesaving › Lifeboat
Issued 10 March 2003 Resolved
LIFEBOAT BOARDING LADDER BRACKETS TO BE RENEWED. LEGACY COMPONENT DESC: Boarding Ladder
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2003
Resolved 14 March 2003
Navigation › Piloting/Steering
Issued 10 March 2003 Resolved
ARPA NOT OPERATIONAL. LEGACY COMPONENT DESC: ARPA
Action required: 17 - Rectify deficiencies prior to departure
Due 14 March 2003
Resolved 14 March 2003
Navigation
Issued 25 December 1997 Resolved
PROVE PROPER OPERATION OF STBD BRIDGE WING STEERING CONSOLE. (IT IS SLUGGISH PERHAPS IT IS THE SERVO PUMP)
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Lifesaving
Issued 25 December 1997 Resolved
INSTALL A GUARD ON ROTATING GEAR ON THE AIR CONDITION MOTOR PUMP (LOCATED IN EMERG FIRE PUMP ROOM).
Condition: Unknown
Due 9 January 1998
Resolved 9 January 1998
Fire Fighting
Issued 4 December 1996 Resolved
PROVIDE SOLAS APPROVED FIRE NOZZLES.
Condition: Unknown
Due 21 December 1996
Resolved 21 December 1996
Construction/Loadline
Issued 4 December 1996 Resolved
PROVE PROPER OPERATION OF OILY WATER SEPERATOR.
Condition: Unknown
Due 21 December 1996
Resolved 21 December 1996
Accommodation/Occupational Safety
Issued 4 December 1996 Resolved
REPAIR HAND RAILS ALONG TOP OF CARGO HOLD AT LADDER.
Condition: Unknown
Due 21 December 1996
Resolved 21 December 1996
Documentation
Issued 4 December 1996 Resolved
PROVIDE OIL POLLUTION PLACARD NEAR OILY WATER SEPERATOR.
Condition: Unknown
Due 21 December 1996
Resolved 21 December 1996
Documentation
Issued 4 December 1996 Resolved
AMEND IOPP CERTIFICATE TO REFLECT CORRECT SLUDGE TANK CAPACITY.
Condition: Unknown
Due 21 December 1996
Resolved 21 December 1996
Documentation
Issued 10 December 1991 Resolved
The vessel has a fuel capacity of 96,000 gallons and the Oil Transfer Procedures were incomplete in that they did not state (1)The procedures forcommunications and (2)procedures for closing valves upon completion of transfer.
Condition: Unknown
Due 31 December 1991
Resolved 31 December 1991

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.