Records from 1984 to 2004. Most recent: operational control imposed, 29 March 2004.
Inspection history · 67
28 March 2004
Certificate of Compliance
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2032676
2 May 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1784877
2 January 2003
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1725134
5 December 2002
Annual Inspection · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1714664
9 September 2001
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 293567
21 August 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 292930
28 February 2001
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 287488
7 February 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 182208
2 July 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 279514
1 July 2000
Tank Vessel Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1464956
1 April 2000
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 138610
1 July 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 430324
24 June 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 430058
23 October 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 421846
7 September 1998
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 420057
20 August 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 419394
25 July 1998
Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 502418
12 July 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 418502
12 July 1998
Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 795136
18 May 1998
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 416120
14 July 1997
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 405781
3 July 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 405684
12 February 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 503577
2 February 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 195462
2 February 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 496391
2 February 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 755210
1 October 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 205858
1 October 1995
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 752705
20 January 1995
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 869763
28 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 373567
28 December 1994
Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1380133
22 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 457696
30 August 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 864724
7 January 1994
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1164211
5 January 1994
Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1161276
10 September 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 523674
5 May 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 499224
10 February 1993
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 124949
30 December 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 440955
24 November 1992
Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1140524
12 November 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 656791
27 October 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 530911
27 October 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1242680
6 October 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 16644
22 May 1992
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 488816
28 April 1992
Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 954038
21 January 1992
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1255780
12 December 1991
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 347551
12 December 1991
Certificate of Compliance
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 949310
3 November 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 347105
18 December 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 340884
18 December 1990
Certificate of Compliance
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1226151
19 August 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 452888
19 August 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1037267
22 October 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 457750
6 June 1987
Certificate of Compliance
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324920
30 April 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1013854
6 April 1987
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 483306
20 December 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 523190
30 May 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 309259
30 May 1986
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 989493
8 May 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 308653
15 November 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 509501
30 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 471317
28 May 1985
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 302368
17 October 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 298391
16 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 297024
Fire Fighting › Fire Main
Issued 28 March 2004
Resolved
Firemain piping to paint locker sprinkler system. Noted excessive exterior wastage to length of pipe running along aft section of foc'sle bulkhead. Pressurized and tested firemain with no leaks noticable. Chief engineer volunteered to crop and renew bad section of piping. LEGACY COMPONENT DESC: Condition
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2004
Resolution: Piping replaced, notification in documentation
Fire Fighting › Fire Hydrants
Issued 28 March 2004
Resolved
Firemain piping to foam station. Noted excessive exterior wastage to length of pipe leading to hose station. Pressurized and tested firemain with no leaks noticable. Chief engineer volunteered to crop and renew bad section of piping. LEGACY COMPONENT DESC: Condition
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2004
Resolution: Piping replaced, notification in documentation
Deck/Cargo
Issued 28 March 2004
Resolved
Noted excessive exterior wastage on 1" hydraulic bypass hard line for #5 cargo tank sludge pump. Chief engineer volunteered to crop, renew, and pressure test this line. Item was listed on COC
Action required: 15 - Rectify deficiencies by next port
Resolved 2 April 2004
Resolution: Piping replaced, notification in documentation
Construction/Loadline › Structures
Issued 11 December 2002
Resolved
Vessel must provide Class report for repairs to the cargo tank top in way of cargo manifold, prior to loading any cargos. LEGACY COMPONENT DESC: Deck Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 December 2002
Resolved 2 January 2003
Resolution: Received Class report issued 21DEC02 by DNV #53420093 DNV ID # 17804
Deck/Cargo
Issued 21 August 2001
Resolved
IGS Deck seal corroded and leaking water._x001C_ Solas 74 (amended) CH II-2 Reg 62.10.2
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Documentation
Issued 21 August 2001
Resolved
IOPP Certification of incinerator capacity in conflict with label on incinerator. 400l/h vs 45l/h._x001C_ Marpol 73/78 annex I.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Fire Fighting
Issued 21 August 2001
Resolved
Fixed Fire Fighting System (Halon) for engine room, discharged. Solas 74 (amended) CH II-2 Reg 5. _x001C_
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Deck/Cargo
Issued 21 August 2001
Resolved
Deck riser flame screen clogged. _x001C_ Solas 74 (amended) CH II-2 Reg 59.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Electrical
Issued 21 August 2001
Resolved
Light fixtures (2) by O2 and acetylene storage STBD side main deck, damagedfire hazard. Solas 74 CH I Reg 11/Solas 74 unamended, CH II-2/2.
Condition: Unknown
Due 10 September 2001
Resolved 10 September 2001
Fire Fighting
Issued 24 June 1999
Resolved
PIPING ON THE FOAM LINE IS WASTED NEAR DECK STOWAGE LOCKER.
Condition: Unknown
Due 9 July 1999
Resolved 9 July 1999
Navigation
Issued 12 July 1998
Resolved
Provide company policy on acceptable under keel clearance.
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Navigation
Issued 12 July 1998
Resolved
Provide maneuvering performance capability as per IMO resolution A.751(18)
Condition: Unknown
Due 20 August 1998
Resolved 20 August 1998
Navigation
Issued 12 July 1998
Resolved
Provide maneuvering and vessel status information as per IMO resoulution A.601(15)._x001C_
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Electrical
Issued 14 July 1997
Resolved
COMPLY WITH CONDITIONS OF CLASS (LR LTR ISSUED 14JUL97) CONCERNING REPAIR OF AUTOSTART ON EMERGENCY GENERATOR.
Condition: Unknown
Due 24 July 1998
Resolved 24 July 1998
Deck/Cargo
Issued 3 July 1997
Resolved
HAVE CLASS SOCIETY ATTEST TO PROPER INSTALLATION OF AFT EMERGENCY TOWING EQUIPMENT AFTER INSTALLED AT NEXT DRYDOCK IN JANUARY.
Condition: Unknown
Due 23 October 1998
Resolved 23 October 1998
Navigation
Issued 3 July 1997
Resolved
PROVIDE SURVEY/INSTALLATION REPORTS FROM RADIO HOLLAND FOR AUTOPILOT ALARM/AUTOMATIC OVERRIDE SYSTEM IAW 33 CFR 157.07. HAVE CLASS SOCIETY PROVE PROPER OPERATION. IF SYSTEM CANNOT BE INSTALLED AS PLANNED IN FREEPORT, TX VSL MUST APPLY FOR A TEMP. LTR OF EQUIVALENCY THROUGH USCG.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Deck/Cargo
Issued 3 July 1997
Resolved
HAVE CLASS SOCIETY PROVE PROPER OPERATION OF CARGO TANK HIGH LEVEL/OVERFILLALARMS WITH VISUAL/AUDIBLE ALARMS ONCE INSTALLED ON BOARD. TO BE DONE PRIOR TO LOADING AT NEXT U.S. PORT OR AT NEXT DRYDOCK, WHICHEVER COMES FIRST.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Electrical
Issued 3 July 1997
Resolved
PRIOR TO NEXT U.S. PORT, REPAIR GEAR FOR STARTING EMERGENCY GENERATOR. CLASS SOCIETY IS TO ATTEST TO ITS PROPER OPERATION BOTH MANUALLY & AUTOMATICALLY & CONFIRM ITS ABILITY TO SUSTAIN A LOAD AS SHOWN ON EMERGENCYBUS SWITCHBOARD.
Condition: Unknown
Due 14 July 1997
Resolved 14 July 1997
Deck/Cargo
Issued 28 December 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF THE VESSEL'S IGS OXYGEN ALARMS AND RECORDER.
Condition: Unknown
Due 28 December 1994
Resolved 29 December 1994
Deck/Cargo
Issued 28 December 1994
Resolved
Make permanent repairs to #2 IGS blower housing in the way of plastic steeltemporary repairs.
Condition: Unknown
Due 28 December 1994
Resolved 28 December 1994
Fire Fighting
Issued 5 January 1994
Resolved
REPLACE / RENEW LEAKING F/F FOAM VALVE ON MAIN DECK IN WAY OF STBDSIDE #5 CARGO TANK BEFORE NEXT U.S. VOYAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Navigation
Issued 5 January 1994
Resolved
INSTALL LOW LEVEL HYDRAULIC, AUDIBLE & VISUAL ALARM ON BRIDGE PRIOR TO_x001C_ NEXT U.S. VOYAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Deck/Cargo
Issued 5 January 1994
Resolved
MAKE PERMANENT REPAIRS TO IGS PIPING ON MAIN DECK IN WAY OF #5 CARGO TANK WHERE TEMPORARY PATCH HAS BEEN PLACED, PRIOR TO NEXT U. S. VOYAGE.
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Documentation
Issued 5 January 1994
Resolved
INSTALL POLLUTION PLACARD IN ENGINE ROOM.
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Fire Fighting
Issued 5 January 1994
Resolved
PROFESSIONALLY SERVICE ALL SCBA'S PRIOR TO DEPARTURE FROM PORT OF HOUSTON._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 January 1994
Resolved 13 January 1994
Deck/Cargo
Issued 5 January 1994
Resolved
MAKE PERMANENT REPAIRS TO DAMAGED P/V VALVE IN WAY OF #3 PORT BALLAST TANK_x001C_BEFORE NEXT U.S. VOYAGE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 January 1994
Resolved 5 January 1994
Construction/Loadline
Issued 5 January 1994
Resolved
DEMONSTRATE PROPER OPERATION OF OWS TO COTP HOUSTON PRIOR TO DEPARTURE FROMTHE PORT OF HOUSTON._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 January 1994
Resolved 7 January 1994
Deck/Cargo
Issued 19 August 1988
Resolved
CONDUCT HYDROSTATIC TEST TO 1.5X MAWP ON CARGO PIPING AND FUEL PIPING IN ACCORDANCE WITH 33 CFR 156.170 NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 19 August 1988
Resolved 19 August 1988
Deck/Cargo
Issued 19 August 1988
Resolved
MAKE PERMANENT REPAIRS IN WAY OF SOFT PATCHES ON DECK WATER SEAL OF INERT GAS SYSTEM NO LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 19 August 1988
Resolved 19 August 1988