GLOBAL EPICA is a 1980 freight ship. The Coast Guard has recorded 7 inspections since 1984, most recently in April 1997, along with 27 deficiencies and 1 operational control.
Records from 1984 to 1997. Most recent: inspection, 2 April 1997.
- Built
- 1980
- Last inspected
- 2 April 1997
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 27 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7916583 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3EOJ9
227962
Flag
JAPAN
—
Maury page id
psix-227962
Inspections, by type
…with no type recorded7
Years with a record
6 calendar years (1984–1997)
The 7 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it35691 - Regulatory (Subpart C or D), Gross Ton
19273 - Regulatory (Subpart C or D), Net Ton
62412 - Dead Weight, Ton
19273 - Regulatory (Subpart C or D), Net Ton
62412 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 7
2 April 1997
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 402091
24 August 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 394108
30 January 1996
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 387447
1 November 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 384352
5 February 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 321186
30 January 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306691
30 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 516503
Deficiency record · 27
Navigation
Issued 2 April 1997
Resolved
MAKE PERMANENT REPAIRS TO STEERING GEAR HYDRAULIC PUMP, EXCESSIVE LEAKAGE. COMPLETE PRIOR TO NEXT U.S. PORT CALL. SOLAS CH II-1 REG29
Deck/Cargo
Issued 2 April 1997
Resolved
MAKE PERMANENT REPAIRS TO THE HYDRAULIC LEAKS ON THE FWD AND AFT MOORING WINCHES AND THE #2 CARGO HATCH CONTROL VALVE. COMPLETE PRIOR TO THE NEXT U.S. PORT CALL. 33CFR 151
Navigation
Issued 30 January 1996
Resolved
Clean the excessive hydraulic oil from about the steering gear machinery decks and from underneath the pumps prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-2/2
Fire Fighting
Issued 30 January 1996
Resolved
Replace the broken closure device on the fire door to the engineroom from the main deck prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-2/47.2
Electrical
Issued 30 January 1996
Resolved
Replace the missing guard on the explosion proof light in the paint locker and clean up space prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/45.5.4
Accommodation/Occupational Safety
Issued 30 January 1996
Resolved
Repair toilet in hospital space to allow for operation without leakage intocabin below prior to return to a U. S. port._x001C_ _x001C_ ILO 147
Engineering
Issued 30 January 1996
Resolved
Provide mechanical plugs (threaded) for lube / fuel oil containments prior to return to a U. S. port._x001C_ _x001C_ 33 CFR 155.320
Engineering
Issued 30 January 1996
Resolved
Provide containment for the lube oil manifold and sludge oil connections located at stbd side, aft next to deck stores prior to return to a U. .S port._x001C_ 33 CFR 155.320
Construction/Loadline
Issued 30 January 1996
Resolved
Make permanent repairs to the 3' fracture of the aft transverse bulkhead incargo hold #6 prior to further cargo operations._x001C_ _x001C_ ICLL 66 I/1
Lifesaving
Issued 30 January 1996
Resolved
Prove proper operation of the stbd lifeboat enigne. Engine could not be started due to cold weather. Complete prior to departure._x001C_ _x001C_ SOLAS 74 III/41.6
Construction/Loadline
Issued 30 January 1996
Resolved
Make permanent repairs to (a) the wrinkled section of the fwd corrugated bulkhead and (b) leaking ballast tank in the fwd, upper wing tank adjacent to the fwd transverse bulkhead. Complete repairs prior to return to a U. S. port. ICLL 66 I/1
Construction/Loadline
Issued 30 January 1996
Resolved
Make permanent repairs to the (a) two doubled sections of the fwd transverse bulkhead and (c) poorly repaired / wrinkled section of the aft transverse bulkhead in cargo hold #6 prior to return to a U. S. port._x001C_ ICLL 66 I/1
Construction/Loadline
Issued 30 January 1996
Resolved
The rubber seams between the coiling steel hatch covers (all 7) are badly cracked and patched in numerous locations. Replace all rubber seams prior to return to a U. S. port._x001C_ ICLL 66 II/15
Construction/Loadline
Issued 30 January 1996
Resolved
Permanently repair the scupper overboard sea valve (port, lower level, behind F/W head tank). Valve is enclosed in a cement box. Complete prior to return to a U. S. port._x001C_ ICLL 66 II/22.1
Fire Fighting
Issued 30 January 1996
Resolved
Make repairs to the emergency fire pump vacuum pump and prove proper operation of emergency fire pump prior to departure._x001C_ _x001C_ SOLAS 74 II-2/4.3.3.2
Documentation
Issued 30 January 1996
Resolved
Provide current licenses for the Chief mate and First engineer. Both are expired. Complete prior to departure._x001C_ _x001C_ STCW 78
Engineering
Issued 30 January 1996
Resolved
Make permanent repairs to the patched cooling line on the stbd, fwd generator engine prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Accommodation/Occupational Safety
Issued 30 January 1996
Resolved
Make permanent repairs to the patched eductor on the fresh water maker prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Engineering
Issued 30 January 1996
Resolved
Make permanent repairs to the patched cooling line on the stbd, aft generator engine prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Electrical
Issued 30 January 1996
Resolved
Repair electrical box on F/O purifier. It is attached with tape and is broken. Complete prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/40.1.3
Engineering
Issued 30 January 1996
Resolved
Repair the leak on the stbd feed water pump to the auxiliary boiler prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Electrical
Issued 30 January 1996
Resolved
Provide electrical mats in front of the main control room switch boards prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/45.2
Engineering
Issued 30 January 1996
Resolved
Make permanent repairs to the patched cooling lines (2) on the main engine port air box prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Engineering
Issued 30 January 1996
Resolved
Make permanent repairs to the patched cooling line to the cascade tank heatexchanger prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Engineering
Issued 30 January 1996
Resolved
Repair the leaking steam valves by the lower purifier, upper purifiers and M/E H/O heaters prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/26.1
Engineering
Issued 30 January 1996
Resolved
Make permanent repairs to the patched OWS tanks (2). Tanks are patched with liquid metal and marine tape. Complete prior to return to a U. S. port. _x001C_ MARPOL 73/78 I/16
Electrical
Issued 30 January 1996
Resolved
Trace and eliminate the partial ground on the main switchboard prior to return to a U. S. port._x001C_ _x001C_ SOLAS 74 II-1/40.1.3
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National