MAURY USCG vessel records Sign in
← All vessels

ZHEN HUA 11

ZHEN HUA 11 is a 1981 freight ship. The Coast Guard has recorded 46 inspections since 1984, most recently in May 2006, along with 27 deficiencies and 3 operational controls.

Records from 1984 to 2006. Most recent: inspection, 26 May 2006.

Built
1981
Last inspected
26 May 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7917446 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B3190
227974
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-227974

Inspections, by type

…with no type recorded30
Years with a record 12 calendar years (1984–2006)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it37743 - Convention (Subpart B), Gross Ton
11323 - Convention (Subpart B), Net Ton
64021 - Displacement, Ton
45403 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 46

26 May 2006 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2659634
16 May 2006 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2650385
11 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2647167
10 May 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2650421
24 December 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 517245
15 November 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 866182
13 October 1994 Tank Vessel Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1354998
19 September 1994 Damage Survey
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 867468
18 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 143089
20 July 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 368739
4 February 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 505027
2 October 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 828191
26 February 1993 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 484395
2 September 1992 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 352886
25 June 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 956088
1 June 1992 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 962622
26 May 1992 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 953714
9 May 1992 Certificate of Compliance
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1253100
27 September 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 440427
26 September 1991 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 935603
30 April 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 343414
23 January 1991 Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 920720
22 January 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 341286
31 August 1990 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 471675
25 April 1990 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1241732
22 January 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 334971
9 January 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216304
9 June 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 448382
23 March 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 329112
20 January 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 516696
20 January 1989 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1201482
26 April 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 464530
11 January 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1318306
28 August 1987 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 318384
28 August 1987 MARPOL Annex II Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1004283
16 March 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 522110
8 September 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 311337
8 September 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1333275
19 August 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310888
28 May 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309071
25 March 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999116
21 March 1986 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999115
23 September 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 304412
26 June 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 503763
8 January 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 299709
22 September 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 298033

Deficiency record · 27

Electrical › Electric Generation Source (emergency) › Generator
Issued 16 May 2006 Resolved
The gear on the starter for the emergency generator is stripped and will not start the engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2006
Resolution: Received the technicians report attesting the repairs of the emergency generator.
Unknown
Issued 13 October 1994 Resolved
PROPERLY SECURE PORTABLE DIESEL FUEL TANK ON AFT MAIN DECK TO PREVENT MOVEMENT PRIOR TO CARGO OPS NEXT U.S. PORT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Electrical
Issued 13 October 1994 Resolved
INSTALL APPROVED RUBBER MATTING AT FRONT OF EMERGENCY GENERATOR DISTRIBUTION PANEL PRIOR TO CARGO OPS IN NEXT U.S. PORT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Fire Fighting
Issued 13 October 1994 Resolved
REMOVE TIE-BACK HOOKS FROM ALL STAIR TOWER FIRE SCREEN DOORS PRIOR TO CARGOOPS.
Condition: Unknown
Due 13 October 1994
Resolved 8 November 1994
Fire Fighting
Issued 13 October 1994 Resolved
REMOVE PAPER AND LOOSE GEAR FROM BEHIND AND ON TOP OF MAIN ELECTRICAL DISTRIBUTION PANEL IN ENGINEERING CONTROL ROOM PRIOR TO CARGO OPS NEXT U.S.PORT.
Condition: Unknown
Due 13 October 1994
Resolved 13 October 1994
Unknown
Issued 19 September 1994 Resolved
VESSEL HAD STEERING GEAR CASUALTY IN PORT OF HOUSTON. CONTROL EQUIPMENT (i.e. ELECTRO VALVE) FAILED.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Navigation
Issued 19 September 1994 Resolved
PRIOR TO DEPARTURE PORT OF HOUSTON, MAKE PERMANENT REPAIRS TO RUDDER ANGLE INDICATOR TO READ SAME AS HELM SETTING. REMOVE SLUGGISH ACTION IN RUDDER ANGLE INDICATOR TO DISPLAY PROPER MOVEMENT OF RUDDER. PROVIDE CLASS SOCIETYREPORT.
Condition: Unknown
Due 14 October 1994
Resolved 14 October 1994
Navigation
Issued 19 September 1994 Resolved
PRIOR TO NEXT U.S. VOYAGE, MAKE PERMANENT REPAIRS TO RUDDER ANGLE INDICATORSYSTEM TO CORRECT 3 DEGREE PORT ERROR. RUDDER POSITION AND RUDDER ANGLE INDICATOR TO READ SAME.
Condition: Unknown
Due 19 September 1994
Resolved 19 September 1994
Fire Fighting
Issued 23 January 1991 Resolved
REPLACE FIRE HOSES AS NEEDED ON DECK (SOME HOSES HAVE SEVERAL PINHOLE LEAKS).
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Fire Fighting
Issued 23 January 1991 Resolved
REPLACE NO. 4 PORT WATER BALLAST TANK FLAME SCREEN.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Accommodation/Occupational Safety
Issued 23 January 1991 Resolved
REPAIR LIFERAIL ON MAIN DECK IN THE FOLLOWING AREAS:_x001C_ 1) PORT SIDE, IN VICINITY OF NO. 4 PORT WATER BALLAST TANK._x001C_ 2) STARBOARD AFT QUARTER JUST FORWARD OF STERN.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Electrical
Issued 23 January 1991 Resolved
REPAIR/REPLACE AS NEEDED TANK GAUGING ELECTRIC LINE CONDUIT IN THE FOLLOWING AREAS:_x001C_ 1) NO.3, NO.7 STARBOARD CARGO TANKS._x001C_ 2) NO.2 PORT CARGO TANK.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Electrical
Issued 23 January 1991 Resolved
REPAIR/REPLACE MAIN ELECTRICAL CONDUIT SHIELDING AND SUPPORTS AS NEEDED_x001C_ ON THE MAIN DECK.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Construction/Loadline
Issued 23 January 1991 Resolved
REPLACE WAVE BREAK LOCATED ON STARBOARD SIDE AT NO. 3 CENTER CARGO TANK;_x001C_ REMOVE DAMAGED WAVE BREAK FROM UNDER MAIN DECK PIPING.
Condition: Unknown
Due 23 January 1991
Resolved 23 January 1991
Navigation
Issued 22 January 1991 Resolved
33CFR164.11(r) VESSEL ENTERED THE PORT OF CORPUS CHRISTI, TX WITHOUT MAINTAINING A PROPERLY OPERATING ARPA AS REQUIRED BY 33CFR164.38(b)(1). VESSEL RCVD LETTER OF DEVIATION.
Condition: Unknown
Due 22 January 1991
Resolved 22 January 1991
Construction/Loadline
Issued 9 January 1990 Resolved
SUSPECTED HOLE/S IN BALLAST MAIN LINE WHICH RUNS LENGTH OF SHIP THROUGH CENTERLINE CARGO TANKS ALLOWING CONTAMINATION OF SEGREGATED BALLAST TANKS WITH CARGO. SUSPECT HOLE/S IS LOCATED AFT OF #6 BALLAST WING TANK BRANCH LINES. TO BE CORRECTED PRIOR TO ENTRY NEXT U.S. PORT.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Navigation
Issued 28 May 1986 Resolved
VESSEL COULD NOT PROVIDE POWER TO REMOTE STEERING GEAR POWER/CONTROL SYSTEMFROM ALTERNATIVE POWER SUPPLY (EMERGENCY GENERATOR) AS REQUIRED BY 33CFR164.39(L). REPAIR AS NECESSARY AND PROVE PROPER OPERATION TO THE SATISFACTION OF THE COGNIZANT OCMI/COTP.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986 Resolved
MAKE REPAIRS TO INERT GAS SYSTEM OXYGEN RECORDER IN CARGO CONTROL ROOM.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986 Resolved
VESSEL DID NOT MAINTAIN INERT ATMOSPHERE IN CARGO TANKS AS REQUIRED BY 46CFR32.53-5. UPON EXAMINATION, OXYGEN WAS MEASURED AT 12.4% IN CARGO TANKS. TANKS CONTAINED CRUDE OIL.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Deck/Cargo
Issued 28 May 1986 Resolved
MAKE REPAIRS TO HIGH OXYGEN ALARM FOR INERT GAS SYSTEM IN CARGO CONTROL ROOM.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 21 March 1986 Resolved
MAKE PERMANENT REPAIRS TO #1 PORT CARGO TANK IN WAY OF COLLISION DAMAGE PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Navigation
Issued 21 March 1986 Resolved
REPAIR AND PROVE OPERATION OF STEERING IN ALL MODES AND ALL ASSOCIATED ALARMS.
Condition: Unknown
Due 21 March 1986
Resolved 21 March 1986
Documentation
Issued 22 September 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984
Documentation
Issued 22 September 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984
Deck/Cargo
Issued 22 September 1984 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984
Deck/Cargo
Issued 22 September 1984 Resolved
MAKE PERMANENT REPAIRS TO PORT FWD MOORING WINCH STEAM LINE
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984
Electrical
Issued 22 September 1984 Resolved
RENEW THE EXPLOSIONPROOF LIGHT GLOBE ON THE FACE OF SUPERSTRUCTURE (AMIDSHIP)
Condition: Unknown
Due 22 September 1984
Resolved 22 September 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.